PSDC161214 

 

 

 

 

 
 

Features: 

 

 

supply output 12VDC/14A 

 

output voltage adjustment 12V÷ 15VDC 

 

16 outputs, protected with 1A fuses or 
polyswitches, jumper selectable 

 

wide range of supply voltage 176÷264VAC  

 

high efficiency 85% 

    LED indication 

 

 

AW technical output of fuse activation 
indication 

 

protections: 

 

SCP short-circuit protection 

 

OVP over voltage protection 

 

surge protection (AC output) 

 

OLP overload protection 

 

 

 
CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Block diagram 
1.3 Description of PSU components and connectors 
1.4 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication of operating status 
3.2 Technical outputs

 

4. Operation and use. 

4.1 Overload or short circuit of the PSU output  
4.2. Battery-assisted operation 

 

4.3. Maintenance 

 

 

1. Technical description. 
 

1.1  General description 
A regulated PSU is intended for supplying alarm systems devices requiring stabilised voltage of 12V DC 

(12,0V÷15,0V DC) and current efficiency of 16x1A. 

       
The PSU features 16 outputs protected with either F 1A fuses or PTC polyswitches. A 
failure (short circuit) in the circuit of any of the outputs will cause blowing of the fuse-
element or PTC activation and disconnecting the circuit from the DC power (+U). The PSU 
is housed in a metallic enclosure (colour: RAL 9003) with an indication panel. 
              

1.2 Block diagram. (fig.1). 

 

Fig.1. Block diagram of the PSU. 

Содержание PSDC 161214

Страница 1: ...PSDC 161214 v 1 0 PSDC 12V 14A 16x1A Switched mode power supply for CCTV EN Edition 1st 10th Mar2012 ...

Страница 2: ... procedure 3 Operating status indication 3 1 LED indication of operating status 3 2 Technical outputs 4 Operation and use 4 1 Overload or short circuit of the PSU output 4 2 Battery assisted operation 4 3 Maintenance 1 Technical description 1 1 General description A regulated PSU is intended for supplying alarm systems devices requiring stabilised voltage of 12V DC 12 0V 15 0V DC and current effic...

Страница 3: ...vation 6 AW output indicating failure of a particular output OC type normal status L failure hi Z 7 Jumper for the selection of the fuse type Fx Fx x Fx jumper on polyswitch Fx Fx x Fx x jumper off fuse Fig 2 The view of the PSU s pcb Table 2 Elements of the PSU see fig 3 Element no Description 1 L N 230 V AC power connectors PE protection connector 2 LED indication of DC power status main module ...

Страница 4: ...www pulsar pl PSDC161214 4 Fig 3 The view of the PSU ...

Страница 5: ...ensions 285 x 261 x 58 280 x 256 x 50 WxHxD mm 2 Fixing 247 x 225 x Φ 6 WxH Net gross weight 2 23 2 40 kg Enclosure Steel plate DC01 0 8mm colour RAL 9003 Closing Cheese head screw at the front Connectors Power supply 230 V AC Φ0 63 2 05 AWG 22 12 AUX outputs Φ0 51 2 05 AWG 24 12 LB8 AW Φ0 51 2 05 AWG 24 12 Notes The enclosure does not adjoin the assembly surface so that cables can be led Operatio...

Страница 6: ... the connection board through the bushing The shock protection circuit shall be performed with a particular care i e the yellow and green wire coat of the power cable shall stick to one side of the terminal marked with the earth symbol in the PSU enclosure Operation of the power supply without a properly made and fully operational shock protection circuit is UNACCEPTABLE It can result in device da...

Страница 7: ...e fuse of the same parameters in case of a failure If the polyswitch assisted protection has been chosen there will be an automatic disconnection of the output voltage indicated by the green diode going out Then cut off the load from the PSU output for approx 1 minute 4 2 Procedure in case of activating the PSU OVP system When the OVP system is activated the output voltage is automatically cut off...

Страница 8: ...o provide warranty repairs at the earliest convenience however not later that within 14 days from the delivery to the service centre of the manufacturer 7 The repair period mentioned in item 6 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 8 All the services ren...

Отзывы: