PSBSH1012B   

 

 

 

 
 

1.4 Specifications: 
- electrical parameters (tab.3) 
- mechanical parameters (tab.4) 
- operation safety (tab.5) 
- operating parameters (tab.6) 

 
Electrical parameters (tab. 3) 

Mains supply 

230V/AC  (-15%/+10%) 

Current up to 

0,14 A  

Power frequency 

50Hz 

Supply power 

17 W 

Efficiency 

70% 

Output voltage 

11,0 V÷ 13,8 V DC – buffer operation 
10,0 V÷ 13,8 V DC – battery-assisted operation 

Output current 

1,0A (without battery) 
0,8A + 0,2A battery charge 
0,5A + 0,5A battery charge 

Output voltage setting, escalation and keeping 
time 

10ms / 34ms / 12ms 
 

Voltage adjustment range 

12,0 V÷ 14,5 V  

Ripple 

30 mV p-p max. 

Current consumption by PSU systems 

13 mA – battery assisted operation 

Battery charge current 

0,2A / 0,5A - 

I

BAT  

jumper selectable 

Short-circuit protection SCP  

200% ÷ 250% of supply power current limitation and/or fuse 
damage in the battery circuit (fuse-element replacement 
required) 

Overload protection OLP 

110% ÷ 150% (@25ºC) of power supply - limitation with the 
PTC  automatic fuse, manual restart (the fault requires the 
disconnection of the DC output circuit) 

Battery circuit SCP and reverse polarity 
protections

 

2A - current limitation, F

BAT

 fuse (in case of a failure, fuse-

element replacement required) 

Excessive discharge protection UVP 

U<10,0 V (± 5%) – disconnection of (- BAT) battery, 
configuration by the P

BAT

 jumper 

Technical outputs: 
- FAC; indicates AC power failure 
- TAMPER indicates enclosure opening

 

 
- R-relay type, 1A@ 30Vdc/50Vac max. 
time lag about 5s/140s/1040s/2h20m30s (+/-5%) 
- microswitch, NC contacts (

enclosure closed

),  

0,5A@50V DC (max.) 

F

BAT 

fuse 

F

MAIN 

fuse 

F2A / 250V 
T315mA / 250V 

Mechanical parameters (tab. 4). 

Enclosure dimensions 

185 x 265 x 95  (WxHxD) [mm] (+/- 2) 

Fixation 

154 x 253 x 

Φ

 6  x4 (WxH)   

Fitting battery  

7Ah/12V (SLA) max. 

Net/gross weight 

2,0/2,2 kg 

Enclosure colour 

ABS, IP65, light grey 

Closing 

Cheese head screw (at the front), lock assembly possible 

Connectors 

Power-supply: 

Φ

0,63÷2,50 (AWG 22-10) 

Outputs: 

Ф

0,41÷1,63 (AWG 26-14),  

Battery output BAT: 6,3F-2,5, 30cm,  
TAMPER output: wires, 30cm 

Notes 

The enclosure has a removable mounting board with the PSU 
systems.

 

    Operation safety (tab.5). 

Protection class PN-EN 60950-1:2007 

I (first) 

 Degree of Protection PN-EN 60529: 2002 (U) 

IP65 
glands installation required: 
P9 (Ф 4-8mm)  x2 
P13,5 (Ф 6-12mm)  x1 

Electrical strength of insulation: 
- between input and output circuits of the PSU (I/P-O/P) 

 
3000 V/AC min. 

Содержание PSBSH 1012B

Страница 1: ...PSBSH 1012B v 1 0 PSBSH 13 8V 1A 7Ah HERMETIC Buffer switch mode power supply unit EN Edition 1 st from 16 th of November 2011 Supercedes the edition ...

Страница 2: ...ion and use 4 1 Overload or short circuit of the PSU output 4 2 Battery assisted operation 4 3 Maintenance 1 Technical description 1 1 General description A buffer PSU is intended for an uninterrupted supply to alarm systems devices requiring stabilized voltage of 12V DC 15 The PSU provides voltage of 13 8 V DC Current efficiency 1 Output current 1 0A without battery 2 Output current 0 8A 0 2A bat...

Страница 3: ... installed jumper removed 2 START button launching from battery 3 VADJ potentiometer voltage adjustment DC 4 FBAT fuse in the battery circuit 5 Connectors BAT DC supply output of the battery BAT red BAT black AUX DC supply output AUX U AUX GND FAC AC absence technical output relay assisted Caution In Fig 2 the set of contacts indicates potential free status which corresponds to AC power failure 6 ...

Страница 4: ...ent no Description 1 Isolation transformer 2 Power upply unit board tab 1 fig 2 3 TAMPER microswitches contacts for sabotage protection NC 4 FMAIN fuse in the power supply circuit 230V AC 5 L N connector 230V AC PE protection connector 6 Battery connectors BAT red BAT black Fig 3 The view of the PSU ...

Страница 5: ...ircuit SCP and reverse polarity protections 2A current limitation FBAT fuse in case of a failure fuse element replacement required Excessive discharge protection UVP U 10 0 V 5 disconnection of BAT battery configuration by the PBAT jumper Technical outputs FAC indicates AC power failure TAMPER indicates enclosure opening R relay type 1A 30Vdc 50Vac max time lag about 5s 140s 1040s 2h20m30s 5 micro...

Страница 6: ... Ф 4 8mm x2 P13 5 Ф 6 12mm x1 in the enclosure considering the diameter of power supply and receivers wires Mind the location of the battery and additional equipment 3 Mount the PSU in a selected location and connect the wires with the gland 4 Connect the power cables 230Vac to L N clips of the PSU Connect the ground wire to the clip marked by the earth symbol PE PSU module connector Use a three c...

Страница 7: ...ch indicate power supply unit door status unit closed NC unit opened NO 4 Operation and use 4 1 Overload or short circuit of the PSU output The AUX output of the PSU is equipped with the PTC polymer fuse protection If the load of the PSU exceeds Imax load 110 150 25ºC of the PSU power the output voltage is automatically cut off and indicated by the green diode going off Cut off the output load for...

Страница 8: ...entioned in item 6 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 8 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer exclusively 9 The warranty does not cover the defects of the equipment resulting from...

Отзывы: