background image

www.pulsar.pl 

 

 

 

 

PSBOC251215 

 

 

 

 

 
 

4.3 Maintenance 
Any  and  all  maintenance  operations  may  be  performed  following  the  disconnection  of  the  PSU  from  the 

power  supply  network.  The  PSU  does  not  require  performing  any  specific  maintenance  measures.  However,  in 
case of significant dust ingress, it is recommended to clean the PSU with compressed air. 

 
 

                         

WEEE MARK 

 
 
 

 

According  to  the  EU  WEE  Directive  –  It  is  required  not  to  dispose  of  electric  or 

electronic waste as unsorted municipal waste and to collect such WEEE separately.

 

 
 

 

 

 
 
 
 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pulsar K.Bogusz Sp.j.  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

 

GENERAL WARRANTY CONDITIONS 

 
 
1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a two-year warranty for the equipment, starting from the initial product date 
of purchase placed on the receipt.  
2. If a purchase proof is missing, a three-year warranty period is counted from the device’s production date.  
3. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 
manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such 
defects have been reported within the warranty period (item 1 and 2).  
4. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the 
manufacturer.  
5. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.   
6. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, however not 
later that within 14 days from the delivery to the service centre of the manufacturer.  
7. The repair period mentioned in item 6 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 
equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  
8. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.  
9. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 
- mechanical damage, 
- improper storage and transport, 
- use that violates the operation manual or equipment’s intended use 
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,  
- improper installation and configuration (in defiance with the manual), 
10. The warranty is void in any of the following circumstances: 
- construction changes  
- repairs carried out by any unauthorized service center 
- damage or removal of warranty labels 
- modifications of the serial number 
11. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the 
wholesale prices suggested by the manufacturer on the day of purchase.  
12. The manufacturer takes no responsibility for the defects that result from:  
- the damaging, malfunctioning or inability to operate the equipment 
- defects that result from using the equipment outside its stated specifications and operating specifications failing to abide by the 
recommendations and requirements contained in the manual, or the use of the equipment.  

 

Содержание PSBOC251215

Страница 1: ...PSBOC251215 v 1 0 PSBOC 13 8V 1 5A OC Caged switched mode buffer power supply unit EN Edition 2nd 19th July 2012 Supersedes edition 1st 10th Mar 2012...

Страница 2: ...al description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED in...

Страница 3: ...sence of DC power 3 LED indicating correct battery voltage 4 FAC AC absence technical output relay type 5 FAC AC absence technical output OC type 6 FPS output indicating DC absence PSU failure OC type...

Страница 4: ...SU systems 40 mA Battery charging current 0 5A Short circuit protection SCP electronic automatic recovery Overload protection OLP 105 150 of power supply automatic recovery Battery circuit protection...

Страница 5: ...ng temperature 10 C 40 C Storage temperature 20 C 60 C Relative humidity 20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insolati...

Страница 6: ...of the power cable shall stick to one side of the PE terminal Using the PSU without a properly made and fully operational shock protection circuit is UNACCEPTABLE It can cause a device failure or an...

Страница 7: ...ts after approx 10 seconds CAUTION In Fig 2 the contact set in the potential free status corresponds to a state with no AC power AC power failure FPS technical output indicating absence of DC voltage...

Страница 8: ...ct 6 Should the claim be accepted the manufacturer is obliged to provide warranty repairs at the earliest convenience however not later that within 14 days from the delivery to the service centre of t...

Отзывы: