6.2.3
Battery protection ON/OFF.
This function enables or disables the battery protection against excessive discharge UVP (see section 7.2).
-
use the „>” or „<” buttons to display the
Battery protect.
menu
-
press the „SET” button, the prompt will appear at the end of the line
-
use the „<” or „>” buttons to choose
ON
– battery protection (disconnection) ON
OFF
– battery protection (disconnection) OFF
-
confirm by pressing the „SET” button
6.2.4
Setting the delay time for EPS output indicating 230V AC power loss.
The PSU features adjustable delay for 230V AC power loss indication. The delay time can be selected from
the four available ranges:
- 5s (factory setting)
- 2min 20s
- 17min
- 2h 20min
230V AC power loss is indicated by the
activation of the “EPS FLT” technical output.
-
use the „<” or „>” buttons to display the Delay
time for EPS output
menu
-
press the „SET” button, the prompt will appear at the end of the line