PSACH01244 

   

 

 

3. Operating status indication. 

 

3.1 Technical outputs. 

The  PSU  is  equipped  with  indication  outputs  allowing  transmitting  the  information  of casing  sabotage  (casing 

opening). 

 

 

TAMPER: output indicates opening the power-supply unit, 

output as volt-free contacts which indicate 

power-supply unit door status, unit closed: NC, unit opened: NO.

 

 
4. Operation and use. 

4.1 Overload or short circuit at the PSU output. 

The U1-U2-0V PSU outputs are protected against a short circuit with glass fuse. If the PSU is loaded with 

current exceeding 4A@24V AC (110%for 

÷ 150% of S power), there occurs the F2 and/or F1 fuse damage in the 

230V AC circuit. In case of a failure, replace the fuse of the same parameters. 

 

4.2 Maintenance. 

Any  and  all  maintenance  operations  may  be  performed  following  the  disconnection  of  the  PSU  from  the 

power  supply  network.  The  PSU  does  not  require  performing  any  specific  maintenance  measures.  However,  in 
case of a significant dust level, clean the interior with compressed air. In case of a fuse replacement, use one of the 
same parameters.  

 

 
 