MAINTENANCE
1
9
Regular maintenance will extend the life of this generator and improve its performance. The warranty does not cover items
that result from operator negligence, misuse, or abuse. To receive full value from the warranty, operator must maintain the
generator as instructed in this manual, including proper storage.
Before inspecting or servicing this machine, make sure the engine is off and no parts are
moving. Disconnect the spark plug wire and move it away from the spark plug.
WARNING!
Creating a Temporary Cold Weather Shelter
In an emergency, the original shipping carton can be used as a temporary shelter. The shelter should hold enough heat
created by the generator to prevent icing.
1.
2.
Cut off all flaps.
Slide carton over generator. If necessary, remove the wheel assembly for fit.
Cut off one of the long sides of the carton to expose the units muffler and exhaust. Do not enclose the muffler / exhaust
side of the generator.
3.
4. Maintain 5 feet of clearance between the open side of box and other objects. The exposed side of the box should face
away from the wind and elements.
5. Remove shelter when temperatures reach 40ºF (4ºC).
Pre-Operation Steps
Before starting the engine, perform the following pre-operation steps:
• Check the level of the engine oil and the fuel tank level.
• Make sure the air filter is clean.
• Remove any debris that has collected on the generator and around the muffler and controls. Use a vacuum cleaner to
pick up loose debris. If dirt is caked on, use a soft bristle brush.
• Inspect the work area for hazards.
After Each Use
Follow the following procedure after each use:
• Close the Fuel Valve
• Switch OFF the engine
• Wait for the generator to become cool to the touch
• Store unit in a clean and dry area.
Maintenance Schedule
After First 5 Hours
Change Oil
After 8 Hours or Daily
Clean Debris from Generator and Air Filter area
Check Engine Oil Level
Annually (25 hr Use)
Check and Clean Air Cleaner
Change Engine Oil (Service more often under dirty or dusty conditions)
Check Muffler and Spark Arrester
Annually (100 hr Use)
Service Spark Plug (Replace with NGK BP6ES, Champion N9YC or equivalent)
Inspect Fuel Valve and Fuel Lines for leaks or damage
Inspect Muffler and Spark Arrester
Check and Clean Air Cleaner Assembly, Replace Air Filter
Clean Cooling System Cylinder Head Fins and Flywheel Fan