![Pulsar PG4500iSR Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/pulsar/pg4500isr/pg4500isr_operators-manual_1624635013.webp)
13
OPERATION
Standard Atmospheric Conditions
Ambient Temperature: 77ºF (25ºC)
Barometric Pressure: 750 mmhg
Relative Humidity: 30%
Generator output will vary due to changes in temperature, altitude, and humidity. If the temperature, altitude, and humidity
are higher than standard atmospheric conditions, the generator’s output will be reduced.
How to Start Engin
e - Manual Start
How to Start Engine - Push Button Start
& Remote Start
• Place generator on a level surface. All electrical loads
MUST
be disconnected from generator.
• Battery ON/OFF Switch to “ON” position
• Turn the FUEL VALVE Knob to “ON”
• Push the One Push Start Button until generator starts. Remote Start: push the control Start button until the engine
starts.
(make
sure
battery is connected)
• Disconnect all electrical loads from generator.
• If ambient temperature is below 32ºF (0ºC) allow about 3 minutes for the engine to warm up.
• With the Economy switch in “ON” position, the unit returns to normal operation after the above warm up time.
• Economy switch must be in the “OFF” position when using electrical devices that require a large starting current, such
as an air compressor.
OFF
ON
ON
OFF
or
• Place generator on a level surface. All electrical loads
MUST
be disconnected from generator.
• Battery ON/OFF Switch to “ON” position
• Turn the FUEL VALVE Knob to “ON”
• Pull the recoil starter grip slowly until resistance is felt; retract, then pull rapidly.
Push Button Start
& Remote Start
START
STOP
Pull cord recoils rapidly and can pull arm towards engine faster than you can let go could result in
injury.
• Pull starter cord slowly until resistance is felt; retract, then pull rapidly.
Note:
To start the generator with the Economy switch in the “ON” position
Manual Start