background image

PG1202S MANUAL

 

WARNING!

 

Never exceed generator’s wattage / amperage capacity.  This could damage the generator

and / or connected electrical devices.

 

Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator.

 

WARNING!

 

Never start or stop engine with electrical devices plugged in to the receptacles. Failure to do
so could damage the generator and / or connected electrical devices.

 

Always start the engine and let it stabilize before connecting any electronic devices.

Disconnect all electronic devices before stopping the engine.

Starter and other moving parts can catch on clothing, jewelry, and hair.

 

Do not wear loose clothing or gloves.

Remove jewelry or anything else that could be caught in moving parts.

Tie back or wear protective head covering to contain long hair.

WARNING!

 

Keep engine away from flammable objects and other hazardous materials.

 

The fuel and its vapors used to power this unit are highly flammable and could explode resulting in serious injury or
death.

Never fill or drain fuel tank indoors.

Never overfill fuel tank.  If fuel spills, move the unit at least 30 feet away from the spill and wipe up any remaining fuel
on the unit before starting the engine.

Never smoke while operating or fueling this unit.

Never operate or store this unit near an open flame, heat, or any other ignition source.

Generator should have at least 5 feet of clearance from buildings or other equipment during operation.

Keep engine free of grass, leaves, or grease which are flammable.

When adding or draining fuel, unit should be turned off for at least 2 minutes to cool before removing fuel cap.  If unit
has been running then the fuel cap is under pressure, remove slowly.

To keep fuel from spilling, secure unit so it cannot tip while operating or transporting.

When transporting unit, disconnect the spark plug wire and make sure the fuel tank is empty with the fuel shutoff valve
turned to the off position.

WARNING!

 

Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which

could result in injury.

 

To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly.

WARNING!

 

Avoid contacting hot areas of this unit.

 

Use caution around the muffler, cylinder, and other engine parts as they can be extremely hot.

Allow hot components to cool before touching.

Содержание PG1202S

Страница 1: ...Generator OPERATOR SMANUAL ITEM PG1202S Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm...

Страница 2: ...enerator 11 Power Management 12 Cold Weather Operation 12 MAINTENANCE 13 Pre OperationSteps 13 After Each Use 13 Maintenance Schedule 13 Air Filter 14 Checking Spark Plug 14 Draining Fuel Tank and Car...

Страница 3: ...Head System Assy 21 Cylinder Barrel 22 Piston and Crankshaft Connecting Rod System Assy 23 Recoil Starter System Assy 24 Carburetor System Assy 25 Flywheel System Assy 26 Ignition System Assy 27 Contr...

Страница 4: ...y electrical power to operate tools appliances camping equipment lighting or serve as a back up power source during power outages AC Output Rated Wattage 900W Rated Voltage 120V Rated Frequency 60Hz R...

Страница 5: ...h If you start to experience any of these symptoms IMMEDIATELY get fresh air and seek medical attention Never use indoors in a covered area or in a confined space even if doors and windows are open In...

Страница 6: ...overfill fuel tank If fuel spills move the unit at least 30 feet away from the spill and wipe up any remaining fuel on the unit before starting the engine Never smoke while operating or fueling this u...

Страница 7: ...ry or death to electric utility workers WARNING Generator must be properly grounded to prevent electrocution Only operate generator on a level surface Always connect the nut and ground terminal on the...

Страница 8: ...PG1202S MANUAL FEATURES 1 Handle 2 Fuel Cap 3 Fuel Tank 4 Fuel Shut Off 5 Recoil Starter 6 Engine On Off Switch 7 Throttle Lever 8 Air Cleaner 9 Control Panel 10 Generator 11 Muffler 12 Cylinder...

Страница 9: ...e all items from the box Make sure all items listed on the packing list are included and not damaged Packing List Check all loose parts to the following list Description Qty Generator 1 Quick Start Gu...

Страница 10: ...tor protects you from electric shock that results from a build up of static electricity or undetected ground faults How to Start Engine WARNING Generator must be properly grounded to prevent electrocu...

Страница 11: ...PG1202S MANUAL Pull the starter grip lightly until you feel resistance then pull briskly to start the engine Move the choke lever to the OPEN position...

Страница 12: ...til it has been checked and or repaired by a qualified technician Never start or stop engine with electrical devices plugged in to the receptacles Failure to do so could damage the generator and or co...

Страница 13: ...Length 230V 8 Wire 10 Wire 12 Wire 14 Wire 16 Wire 2 5 600 X 1000 ft 600 ft 375 ft 250 ft 5 1200 X 500 ft 300 ft 200 ft 125 ft 7 5 1800 X 350 ft 200 ft 125 ft 100 ft 10 2400 X 250 ft 150 ft 100 ft 50...

Страница 14: ...additional load plugged into the generator if solid state equipment such as television set is used A power line conditioner is recommended for some solid state applications Wattage Reference Guide Wa...

Страница 15: ...humid conditions where temperatures drop to 40 F 4 C the carburetor and or crankcase breather system may begin to freeze To prevent icing take the following steps 1 Replace any old fuel with clean fre...

Страница 16: ...r Daily Clean Debris Annually 25 hr Use Check and Clean Air Cleaner Check Muffler Annually 100 hr Use Service Spark Plug Replace with NGK BP6ES Champion N9YC or equivalent Check Clean Fuel Filter Insp...

Страница 17: ...ug is worn replace only with an equivalent replacement part Spark plug should be replaced annually BOSCH F7TC NGK BP6ES CHAMPION N9YC or Equivalent Fig 11 Fig 12 Draining Fuel Tank and Carburetor To h...

Страница 18: ...causing acid and gum deposits in the fuel system and carburetor For long term storage drain the fuel Store the generator indoors to prevent freezing The generator must be Shipped Run and Stored in th...

Страница 19: ...RAMS Rotor Stator R1 R2 D1 D2 FC1 FC2 S C Over Volt Protective Resistance Spin Rectifier Rotor Pole Winding Stator Auxiliary Winding DC MC1 MC2 C D3 Stator DC Winding Stator Main Winding Capacitor Sin...

Страница 20: ...fuel 5 Spark plug wire disconnected from spark plug 6 Bad spark plug 7 Water in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Rich fuel mixture 11 Intake valve stuck open or closed 12 Loss of...

Страница 21: ...or components and labor 12 Month Limited coverage on generator engine and alternator components parts only Personal use means personal residential household use or recreational use by the retail consu...

Страница 22: ...duct has been sold as is or where the factory applied serial number has been removed Refurbished used demonstration or floor models are not covered by this warranty Where Warranty is Valid For warrant...

Страница 23: ...wo stroke lubrication Gasoline and oil mixing ratio 50 1 Displacement 72cc Starting System Recoil Electronic Ignition Spark Plug F6TC LD Cooling System Forced Air Decibel Ratio 76dB Rated Output 72cc...

Страница 24: ...PG1202S MANUAL PARTS LIST...

Страница 25: ...M6 12 2 PG1202S A 02 CYLINDER AIR SHROUD 3 PG1202S A 03 NUT M6 18 4 PG1202S A 04 STUD BOLT M6 110 5 PG1202S A 05 FLANGE BOLT M6 105 6 PG1202S A 06 SPARK PLUG 7 PG1202S A 07 CYLINDER HEAD 8 PG1202S A...

Страница 26: ...55 2 PG1202S B 02 FLANGE BOLT M6 45 3 PG1202S B 03 OIL SEAL 30 20 7 4 PG1202S B 04 RUBBER PAD 5 PG1202S B 05 CRANKCASE LEFT 6 PG1202S B 06 BEARING 6004 7 PG1202S B 07 SPEED REGULATION FORK 47 8 PG1202...

Страница 27: ...ystem Assy C No Parts No Description 1 PG1202S C 01 COMPRESSION RING A 2 PG1202S C 02 COMPRESSION RING B 3 PG1202S C 03 PISTON 4 PG1202S C 04 PISTON PIN 5 PG1202S C 05 PISTON PIN CLIP 10mm 6 PG1202S C...

Страница 28: ...ING COVER 2 PG1202S D 02 STARTER KNOB 3 PG1202S D 03 RECOIL STARTER ROPE 4 PG1202S D 04 START RETURN SPRING 5 PG1202S D 05 RECOIL STARTER REEL 6 PG1202S D 06 BEARING PLATE 7 PG1202S D 07 DRIVE PLATE 8...

Страница 29: ...No Parts No Description 1 PG1202S E 01 AIR INLET VALVE BODY GASKET 2 PG1202S E 02 AIR INLET VALVE BODY 3 PG1202S E 03 FLANGE BOLT M6 20 4 PG1202S E 04 CARBURETOR GASKET IN 5 PG1202S E 05 CARBURETOR AS...

Страница 30: ...PG1202S MANUAL Flywheel System Assy F No Parts No Description 1 PG1202S F 01 FLANGE NUT M10 1 25 2 PG1202S F 02 FLYWHEEL...

Страница 31: ...ion System Assy G No Parts No Description 1 PG1202S G 01 FLANGE BOLT M6 12 2 PG1202S G 02 MAGNETO 3 PG1202S G 03 LOCATINGT 4 PG1202S G 04 HIGH VOLTAGE SET 5 PG1202S G 05 STOP SWITCH CORD 6 PG1202S G 0...

Страница 32: ...RNING SPRING 5 PG1202S H 05 FLANGE NUT M6 6 PG1202S H 06 SHIFTET 7 PG1202S H 07 GOVERNOR ARM 8 PG1202S H 08 BOLT M6 20 9 PG1202S H 09 THROTTLE RETURN SPRING 10 PG1202S H 10 GOVERNOR ROD 11 PG1202S H 1...

Страница 33: ...PG1202S MANUAL Muffler System Assy I No Parts No Description 1 PG1202S I 01 FLANGE BOLT M6 12 2 PG1202S I 02 MUFFLER COMP 3 PG1202S I 03 MUFFLER GASKET...

Страница 34: ...J 02 CLAMP 3 PG1202S J 03 FUEL TUBE 4 PG1202S J 04 FUEL CONTROL VALVE 5 PG1202S J 05 FUEL TANK 6 PG1202S J 06 FUEL FILTER 7 PG1202S J 07 FUEL CUP 8 PG1202S J 08 FUEL CAP 9 PG1202S J 09 HANDLE 10 PG120...

Страница 35: ...G1202S K 07 SPRING WASHER 6 8 PG1202S K 08 WASHER 6 9 PG1202S K 09 CONTROL PANEL 10 PG1202S K 10 CAPACITOR 11 PG1202S K 11 PLATE SCREW ST4 16 12 PG1202S K 12 TUBE 6 13 PG1202S K 13 PLATE COVER 14 PG12...

Страница 36: ...01 STATOR ASSY 2 PG1202S L 02 ROTOR COMP 3 PG1202S L 03 FLANGE BOLT M8 155 4 PG1202S L 04 RUBBER PAD 5 PG1202S L 05 GENERATOR STAY 6 PG1202S L 06 FLANGE BOLT M6 80 7 PG1202S L 07 FLAT SCREW M4 20 8 P...

Отзывы: