5. Technical data 

 

MOUSE 07 

 

Power supply 

9÷15VDC 

Power consumption: Alarm / Standby 

23,0mA /19,0mA@13,8VDC 

Sensor range 

up to 14m  

Operating angle 

90° 

PIR Sensor 

2 components 

Lens 

29 areas in 5 levels 

Microwave frequency 

10,525GHz 

Microwave power 

10mW 

Alarm signaling time 

3s 

Alarm type 

AND  / OR AUTO 

Tamper protection (opening of the detector) 

YES 

Creep zone detection 

YES 

Alarm memory 

YES 

Maximum load of the contacts of the relay 

100mA@40VDC  /2,5-16Ω 

Maximum load of the contacts of the tamper 

40mA@30VDC 

Operating temperature 

-10°C÷55°C 

Storage Temperature 

-20°C÷60°C 

Electromagnetic immunity 
(radio frequency interference) RFI 

30V/m (80MHz-2000MHz)* 

LED (walk test) 

YES 

In accordance to the standard 

EN 50131-2-4 Grade 2 

Enclosure material 

ABS 

Accessories  

Rotary handle (SN-1 version)** 

Dimensions (H x W x D) 

110 x 60 x 46mm 

Resistance to animals  

NO 

 
 

In accordance with the standards: 
 
R&TTE 99/5/CE  
EN 50131-2-4: 2008  
EN 50131-2-4 Grade 2  
EN 50131-2-4 Class 2  
CEI 79-2: I° Level
 

 

 

RoHS 

 

 

 

 
* Required RFI immunity: 10V/m  
**

 

The holder does not comply with the EN 50131-2-4 standard 

 

Additional information 

The  manufacturer takes no responsibility for the defects that result from the  damaging,  malfunctioning or 

inability to operate the equipment especially when resulting from failure to comply with the recommendations 
and requirements contained in the manual. 

It  is  necessary  to  periodically  test  the  signaling  device.  The  majority  of  Intrusion  Detection  Systems 

indicates  malfunctioning  of  the  signaling  devices and  informs  the  user  with  an  appropriate  message  on  the 
LCD  keypad  or  LED  light  on  the  LED  display.  In  case  of  such  situation,  the  system  installer  shall  be 
immediately notified. Testing and control  methods of Intrusion Detection Systems are specifically determined 
by the installer. 

The  MOUSE  07  detector  was  made  in  accordance  with  the  requirements  of  the  EEC  and  99/5/CE 

directives. The Declaration of Conformity is available at 

www.pulsar.pl

 

 
 
 
 
 
 
 
 

Содержание MOUSE 07

Страница 1: ... MOUSE 07 detector is up to 14 meters with horizontal coverage exceeding 90 degrees The area of the sensor operation is shown in the Figure 5 2 Installation of the detector The detector should be mounted by a qualified installer holding relevant permits and licenses applicable and required for a given country for Intrusion Detection Systems The latch system used in the enclosure of the detector el...

Страница 2: ...pply voltage and wait until the LED of the sensor stops flashing CAUTION Leave the field of view of the detector The arrangement of the elements of the detector on the PCB is shown in the figure 3a and 3b Fig 3a Printed Circuit Board front view Fig 3b Printed Circuit Board rear view 3 The detector configuration elements The detector configuration uses the following elements mounted on the PCB Pote...

Страница 3: ...r after six detections of the microwave detector within less than 30 seconds DIP3 ON The alarm is generated by both PIR and WM detectors or after three detections of the microwave detector within less than 30 seconds MEM DIP4 Alarm memory DIP4 ON This feature enables determining which detector triggered the alarm which is indicated by flashing LEDs green LED alarm by microwave detector Orange LED ...

Страница 4: ...4 4 Lens Fig 5a Sensor range side view Fig 5b Sensor range top view ...

Страница 5: ...dards R TTE 99 5 CE EN 50131 2 4 2008 EN 50131 2 4 Grade 2 EN 50131 2 4 Class 2 CEI 79 2 I Level RoHS Required RFI immunity 10V m The holder does not comply with the EN 50131 2 4 standard Additional information The manufacturer takes no responsibility for the defects that result from the damaging malfunctioning or inability to operate the equipment especially when resulting from failure to comply ...

Страница 6: ...venience however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has beenconditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manu...

Отзывы: