Perform the following steps to mount the detector: 
 
1.

 

Open the detector by releasing (using thin screwdriver) the latch in the lower part of the enclosure (Fig.1). 

2. Remove the PCB from the base by releasing the locking clip (Fig.2). 
3.

 

Make holes (for mounting the sensor on the wall) in the embossings at the rear or side of the housing. The 

detector can also be mounted on the SN-1 rotating holder (not included). 

4. Lead the cables through the hole located in the upper part of the enclosure (Fig. 2). 
5. Connect the wires to the screw terminals and configure the detector 
  (Information on the distribution of terminals and control elements with a description of the available functions 

can be found in the following pages). 

6. Close the lid of the sensor. 
  CAUTION! When closing the cover of the detector, check whether the spring of the  micro switch tamper is 

correctly pressed into the tapered socket in the lid.  

7. Connect the supply voltage and wait until the LED of the sensor stops flashing.  

CAUTION! Leave the field of view of the detector. 

 
The arrangement of the elements of the detector on the PCB is shown in the figure 3a and 3b.  

 

 

 

Fig. 3a  

Printed Circuit Board (front view)

 

 

Fig. 3b 

 Printed Circuit Board (rear view)

 

 
 

3. The detector configuration elements 

 

The detector configuration uses the following elements mounted on the PCB: 

  Potentiometer  

  Five-position ON/OFF potentiometer  

1.

 

Potentiometer - adjusting the microwave range (MW

 

   

To  adjust  the  microwave  range  of  the  detector,  use  a  potentiometer  located  on  the  PCB  (Fig.  3a).  The  "+" 

increases the range, and the "-" reduces the range of the detector. 

The adjustment should be carried out in several steps. After the initial adjustment and closing the cover, check the area 

of the sensor operation. Re-open the sensor housing and re-adjust the microwave range. Operating range of the MW 
detector is adjusted with the DIP1 switch. 

  Caution!  Detection  sensitivity  of  microwave  path  should  be  adjusted  to  the  size  of  the  protected  space. 

Microwaves can penetrate gypsum walls, doors, etc., which may generate false alarms. 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание MOUSE 07

Страница 1: ... MOUSE 07 detector is up to 14 meters with horizontal coverage exceeding 90 degrees The area of the sensor operation is shown in the Figure 5 2 Installation of the detector The detector should be mounted by a qualified installer holding relevant permits and licenses applicable and required for a given country for Intrusion Detection Systems The latch system used in the enclosure of the detector el...

Страница 2: ...pply voltage and wait until the LED of the sensor stops flashing CAUTION Leave the field of view of the detector The arrangement of the elements of the detector on the PCB is shown in the figure 3a and 3b Fig 3a Printed Circuit Board front view Fig 3b Printed Circuit Board rear view 3 The detector configuration elements The detector configuration uses the following elements mounted on the PCB Pote...

Страница 3: ...r after six detections of the microwave detector within less than 30 seconds DIP3 ON The alarm is generated by both PIR and WM detectors or after three detections of the microwave detector within less than 30 seconds MEM DIP4 Alarm memory DIP4 ON This feature enables determining which detector triggered the alarm which is indicated by flashing LEDs green LED alarm by microwave detector Orange LED ...

Страница 4: ...4 4 Lens Fig 5a Sensor range side view Fig 5b Sensor range top view ...

Страница 5: ...dards R TTE 99 5 CE EN 50131 2 4 2008 EN 50131 2 4 Grade 2 EN 50131 2 4 Class 2 CEI 79 2 I Level RoHS Required RFI immunity 10V m The holder does not comply with the EN 50131 2 4 standard Additional information The manufacturer takes no responsibility for the defects that result from the damaging malfunctioning or inability to operate the equipment especially when resulting from failure to comply ...

Страница 6: ...venience however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has beenconditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manu...

Отзывы: