1. Introduction 

 

 

The  MOUSE  07  is  a  dual  element  digital  motion  detector  with  creep  zone  protection.  With  its 

advanced  signal  processing  algorithms  and  dual  detection  technology  (PIR  and  MW)  it  is  characterized  by 
very stable operation and low rate of false alarms. 

Z  Advanced  digital  temperature  compensation  enables  operation  over  a  wide  temperature  range.  The 

range of the MOUSE 07 detector is up to 14 meters with horizontal coverage exceeding 90 degrees. The area 
of the sensor operation is shown in the Figure 5. 
 

2. Installation of the detector 

 

The detector should  be  mounted by a qualified installer, holding relevant permits and licenses (applicable 

and required for a given country) for Intrusion Detection Systems. 

The latch system used in the enclosure of the detector eliminates the need for screw connections, so that 

the detector installation is simple and does not take much time.  

Follow the basic rules for the installation of Intrusion Detection Systems (pay attention, among others, not 

to soil or damage the pyroelement, do not point the detector towards strong light sources). 

The optimum mounting height of the MOUSE 07 detector is 2 meters).  

 
 
 
 
 
 

 

 
 
 

 

 

 

 

 

Fig. 1 

 Main view 

Fig. 2 

Inside view 

  

Содержание MOUSE 07

Страница 1: ... MOUSE 07 detector is up to 14 meters with horizontal coverage exceeding 90 degrees The area of the sensor operation is shown in the Figure 5 2 Installation of the detector The detector should be mounted by a qualified installer holding relevant permits and licenses applicable and required for a given country for Intrusion Detection Systems The latch system used in the enclosure of the detector el...

Страница 2: ...pply voltage and wait until the LED of the sensor stops flashing CAUTION Leave the field of view of the detector The arrangement of the elements of the detector on the PCB is shown in the figure 3a and 3b Fig 3a Printed Circuit Board front view Fig 3b Printed Circuit Board rear view 3 The detector configuration elements The detector configuration uses the following elements mounted on the PCB Pote...

Страница 3: ...r after six detections of the microwave detector within less than 30 seconds DIP3 ON The alarm is generated by both PIR and WM detectors or after three detections of the microwave detector within less than 30 seconds MEM DIP4 Alarm memory DIP4 ON This feature enables determining which detector triggered the alarm which is indicated by flashing LEDs green LED alarm by microwave detector Orange LED ...

Страница 4: ...4 4 Lens Fig 5a Sensor range side view Fig 5b Sensor range top view ...

Страница 5: ...dards R TTE 99 5 CE EN 50131 2 4 2008 EN 50131 2 4 Grade 2 EN 50131 2 4 Class 2 CEI 79 2 I Level RoHS Required RFI immunity 10V m The holder does not comply with the EN 50131 2 4 standard Additional information The manufacturer takes no responsibility for the defects that result from the damaging malfunctioning or inability to operate the equipment especially when resulting from failure to comply ...

Страница 6: ...venience however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has beenconditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manu...