1.4 Specifications:  
- electrical parameters (tab.3) 
- mechanical parameters (tab.4) 
- operation safety (tab.5) 
- operating parameters (tab.6) 

      

Electrical parameters (tab. 3). 

PSU type 

A (EPS - External Power Source) 

Mains supply 

176÷264V AC  

Current up to 

0.95A@230VAC  

Power frequency 

50÷60Hz or DC 

Supply power 

100W max.  

Efficiency 

80% 

Output voltage 

13,8V DC – buffer operation 
9,5V÷13,8V DC – battery operation 

Output current 

6A + 1A battery charge 
5A + 2A battery charge 

Output current t

AMB

<30°C 

6A + 1A battery charge - refer to chart 1 
5A + 2A battery charge - refer to chart 1 

Output current t

AMB

=40°C 

4,9A + 1A battery charge - refer to chart 1 
3,9A + 2A battery charge - refer to chart 1 

Voltage adjustment range 

12÷14VDC 

Ripple 

120mV p-p max. 

Battery charge current 

1A/2A max. @ 65Ah (± 5%) - jumper selectable 

Short-circuit protection SCP 

electronic 

Overload protection OLP 

PTC polymer fuse 

Overvoltage protection OVP 

U>115% ÷ 150% of the output voltage (set), power 
cut off, automatic return 

Excessive discharge protection UVP 

U<9,5V (± 5%) – 

disconnect of connection battery

 

LED indication:  
- AC diode indicating AC power status 
- AUX diode indicating DC power status at 
the PSU output 

- red, normal status – on, failure: off 
- green, normal status – on, failure: off 

Sabotage protection: 
- TAMPER indicates enclosure opening 

 
- microswitch, NC contacts (enclosure closed), 
0,5A@50V DC (max.) 

 
Mechanical parameters (tab. 4). 

Enclosure dimensions 

400 x 350 x 170+8  [mm] (WxHxD) 

Fixation 

see figure 2 

Fitting battery 

65Ah/12V (SLA) max. 

Net/gross weight 

6,0 / 6,4 kg 

Enclosure  

Steel plate DC01, thickness: 1,0mm, colour: RAL 9003 

Closing 

Cheese head screw x 2 (at the front),  (lock assembly possible) 

Connectors 

Power-supply: Φ0,63-2,50 (AWG 22-10) 
Outputs: Φ0,63-2,50 (AWG 22-10), battery output BAT: 6,3F-2,5  
TAMPER output: wires  

Notes 

The enclosure does not touch the assembly surface so that cables can be led. 
Convectional cooling. 

      

Operation safety (tab.5). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
500  V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

Содержание HPSB 7012E

Страница 1: ...HPSB 7012E v 1 0 HPSB 13 8V 6A 65Ah Buffer switching power supply unit EN Edition 4 from 12 11 2013 Supercedes 3 from 16 09 2013...

Страница 2: ...ply to devices requiring stabilised voltage of 12 V DC 15 The PSU provides voltage of U 13 8 V DC Current efficiency 1 Output current 6A 1A battery charge 2 Output current 5A 2A battery charge Total d...

Страница 3: ...iption 1 PSU module 2 connectors see tab 2 3 green LED indicates AC power 4 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact of sabotage protection...

Страница 4: ...www pulsar pl HPSB7012E 4 Fig 2 The view of the PSU...

Страница 5: ...y LED indication AC diode indicating AC power status AUX diode indicating DC power status at the PSU output red normal status on failure off green normal status on failure off Sabotage protection TAMP...

Страница 6: ...ees sufficient convectional air flow through ventilating holes of the enclosure Before installation prepare a PSU load balance 1 Output current 6A 1A battery charge 2 Output current 5A 2A battery char...

Страница 7: ...o U 13 8V DC 9 After installing and checking proper working the enclosure can be closed 3 Operating status indication 3 1 LED indication of operating status The PSU is equipped with two diodes on the...

Страница 8: ...t within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs o...

Отзывы: