background image

www.pulsar.pl                                                             PSDCB09125C         

 

 

5

 

W

H

D

   1.4 Specifications:  
          - electrical parameters (tab.3) 
          - mechanical parameters (tab.4) 
          - operation safety (tab.5) 
          - operating parameters (tab.6) 
 

      

Electrical parameters (tab. 3) 

Mains supply 

176÷264V AC  

Current up to 

0.95A@230V AC max.   

Supply power 

100W max.  

Efficiency 

80% 

Output voltage 

11V÷13,8V DC – buffer operation 
9,5V÷13,8V DC – battery-assisted operation 

Output current t

AMB

<30°C 

9x0,5A + 1A battery charge - refer to chart 1 
9x0,5A + 2A battery charge - refer to chart 1 

Output current t

AMB

=40°C 

9x0.44A + 1A battery charge - refer to chart 1 
9x0.33A + 2A battery charge - refer to chart 1 

Voltage adjustment range 

12

÷14VDC 

Ripple 

120mV p-p max. 

Battery charge current 

1A/2A max. @ 17Ah (

± 5%) 

Short-circuit protection SCP 

LB9  STRIP 
9x F 0,5A glass fuse  

Overload protection OLP 

105-150% of power supply, automatic recovery 

Battery circuit protection SCP and reverse 
polarity connection 

polymer fuse 

Surge protection 

varistors 

Overvoltage protection OVP 

>16V  (automatic recovery) 

Excessive discharge protection UVP 

U<9,5V (

± 5%) – disconnect of connection battery 

Tampering protection system: 
- TAMPER 

– indicating unwanted opening of the 

PSU’s enclosure 

- microswitch, NC contacts (enclosure closed), 
0,5A@50V DC (max.) 

LED indication:  
- AC diode indicating AC power status 
- AUX diode indicating DC power status at 
the PSU output 

- red, normal status 

– on, failure: off 

- green, normal status 

– on, failure: off 

F1÷F9 fuse 

F 0,5A/250V 

 
Mechanical parameters (tab. 4) 

Enclosure dimensions 

280 x 292 x 80+8 [mm] (WxHxD) 

Fixation 

see figure 3 

Fitting battery 

17Ah/12V (SLA) max. 
185x170x75mm (WxHxD) max  

Net/gross weight 

2.32kg / 2.52kg 

Enclosure 

Steel plate, DC01 0,7mm colour: RAL 9003 

Closing 

Cheese head screw x 2 (at the front), lock assembly possible 

Connectors 

Power supply: 

Φ0,63-2,50 (AWG 22-10) 

Outputs

Ф0,41÷1,63 (AWG 26-14), battery output BAT: 6,3F-2,5  

TAMPER output: wires  

Notes 

The enclosure does not adjoin the assembly surface so that cables can be led. 

      
      Operation safety (tab.5) 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529:2002 (U) 

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
  500 V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

   
 
 
 
 
 

Содержание GREEN POWER CCTV PSDCB09125C

Страница 1: ...PSDCB09125C v 1 0 PSDCB 13 8V 5A 9x0 5A 17Ah Buffer power supply for up to 9 analog cameras EN Edition 5 from 25 05 2015 Supercedes the edition 4 from 16 12 2014 GREEN POWER CCTV ...

Страница 2: ...tections SCP short circuit protection OVP overvoltage protection overvoltage protection against sabotage overload protection OLP warranty 2 year from the production date An example of power supply for analog cameras range 12V 15V DC 9 x 0 5A CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation ...

Страница 3: ...tivated immediately The PSU is constructed based on the switch mode PSU with high energy efficiency The PSU is housed in a metal enclosure colour RAL 9003 which can accommodate a 17Ah 12V battery A micro switch indicates door opening front cover 1 2 Block diagram fig 1 Fig 1 The block diagram of the PSU 1 3 Description of PSU components Table 1 Elements and connectors of the fuse block tab 1 fig 2...

Страница 4: ... 3 green LED indicates AC power 4 P1 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact of sabotage protection NC 7 Additional connector for LED indication 8 Ibat Selection jumper for charging current Ibat 1A Ibat 2A Legend jumper installed jumper removed Factory settings Ibat 1A jumper installed 9 fuse block LB9 Fig 3 The view of the PSU ...

Страница 5: ...system TAMPER indicating unwanted opening of the PSU s enclosure microswitch NC contacts enclosure closed 0 5A 50V DC max LED indication AC diode indicating AC power status AUX diode indicating DC power status at the PSU output red normal status on failure off green normal status on failure off F1 F9 fuse F 0 5A 250V Mechanical parameters tab 4 Enclosure dimensions 280 x 292 x 80 8 mm WxHxD Fixati...

Страница 6: ...A battery charge Total device current battery 7A max As the PSU is designed for a continuous operation and is not equipped with a power switch therefore an appropriate overload protection shall be guaranteed in the power supply circuit Moreover the user shall be informed about the method of unplugging usually through assigning an appropriate fuse in the fuse box The electrical system shall follow ...

Страница 7: ...U outputs are protected against a short circuit by glass fuse In case of fuse damage the replacement of the same parameters is required In case of overload the output voltage is automatically shut off and so is the LED indicator The restoration of the voltage takes place immediately after the failure overload is over 4 2 Battery assisted operation In case of a main power outage the device is immed...

Страница 8: ...days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer...