www.pulsar.pl                                                             PSDCB09125C         

 

 

3

 

1. Technical description. 
 

1.1 General description. 

A buffer PSU is intended for an uninterrupted supply to devices requiring stabilised voltage of 

12V DC  

(+/-15%).

 The PSU provides voltage of 

U=13,8V DC.

 Current efficiency: 

 

 

1.  Output current 9x0,5A + 1A battery charge 
2.  Output current 9x0,5A + 2A battery charge 

                                                     Total device c battery: 7A max

*

 

In case of power decay, a battery back-up is activated immediately. The PSU is constructed based on the switch 

mode PSU, with high energy efficiency. The PSU is housed in a metal enclosure (colour RAL 9003) which can 
accommodate a 17Ah/12V battery. A micro switch indicates door opening (front cover). 

 

           1.2 Block diagram (fig.1)  

 

 

 

Fig.1. The block diagram of the PSU. 

 

1.3 Description of PSU components.  
 
Table 1. Elements and connectors of the fuse block (tab.1, fig.2). 

Element  

[fig. 2] 

Description 

[1] 

F1

÷F9 

glass fuses PTC 

[2] 

LED 

L1 

÷ L9

  signaling presence of output  voltage DC 

[3] 

power supply output

 AUX1

÷AUX9, 

shared terminal

 COM (-)

 

 

 

Fig. 2. The view of the fuse block LB9. 

 
 
 
 
 
 

                                                 

*

 

Refer to chart 1

 

Содержание GREEN POWER CCTV PSDCB09125C

Страница 1: ...PSDCB09125C v 1 0 PSDCB 13 8V 5A 9x0 5A 17Ah Buffer power supply for up to 9 analog cameras EN Edition 5 from 25 05 2015 Supercedes the edition 4 from 16 12 2014 GREEN POWER CCTV ...

Страница 2: ...tections SCP short circuit protection OVP overvoltage protection overvoltage protection against sabotage overload protection OLP warranty 2 year from the production date An example of power supply for analog cameras range 12V 15V DC 9 x 0 5A CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation ...

Страница 3: ...tivated immediately The PSU is constructed based on the switch mode PSU with high energy efficiency The PSU is housed in a metal enclosure colour RAL 9003 which can accommodate a 17Ah 12V battery A micro switch indicates door opening front cover 1 2 Block diagram fig 1 Fig 1 The block diagram of the PSU 1 3 Description of PSU components Table 1 Elements and connectors of the fuse block tab 1 fig 2...

Страница 4: ... 3 green LED indicates AC power 4 P1 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact of sabotage protection NC 7 Additional connector for LED indication 8 Ibat Selection jumper for charging current Ibat 1A Ibat 2A Legend jumper installed jumper removed Factory settings Ibat 1A jumper installed 9 fuse block LB9 Fig 3 The view of the PSU ...

Страница 5: ...system TAMPER indicating unwanted opening of the PSU s enclosure microswitch NC contacts enclosure closed 0 5A 50V DC max LED indication AC diode indicating AC power status AUX diode indicating DC power status at the PSU output red normal status on failure off green normal status on failure off F1 F9 fuse F 0 5A 250V Mechanical parameters tab 4 Enclosure dimensions 280 x 292 x 80 8 mm WxHxD Fixati...

Страница 6: ...A battery charge Total device current battery 7A max As the PSU is designed for a continuous operation and is not equipped with a power switch therefore an appropriate overload protection shall be guaranteed in the power supply circuit Moreover the user shall be informed about the method of unplugging usually through assigning an appropriate fuse in the fuse box The electrical system shall follow ...

Страница 7: ...U outputs are protected against a short circuit by glass fuse In case of fuse damage the replacement of the same parameters is required In case of overload the output voltage is automatically shut off and so is the LED indicator The restoration of the voltage takes place immediately after the failure overload is over 4 2 Battery assisted operation In case of a main power outage the device is immed...

Страница 8: ...days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer...

Отзывы: