www.pulsar.pl                                                      POE042455B   

GREEN POWER CCTV PoE

 

 

 

      

Safety of use (Table 5). 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Insulation electrical strength: 
- between input (network) circuit and the output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit  (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
  500 V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

Operation parameters (Table 6). 

Operating temperature 

-

10ºC...+40ºC (see Figure1) 

Storing temperature 

-

20ºC...+60ºC 

Relative humidity  

20%...90%, no condensation 

Vibrations during operation  

unacceptable 

Surges during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and surges during transport 

According to the PN-83/T-42106 standard 

 

 

Diagram 1.

 

Maximum permissible output current depending on ambient temperature.

 

 
2.  Installation. 

 

2.1. Requirements. 

The  buffer  PSU  should  be  mounted  by  a  qualified  installer,  holding  relevant  permits  and  licenses 

(applicable and  required  for  a  given  country)  for  230V/AC  and  low-voltage  installations. The  unit  should  be 
mounted  in  confined  spaces,  in  accordance  with  the  2nd environmental  class,  with  normal  relative  humidity 
(RH=90% maximum, no condensation) and temperature range from -

10°C up to +40°C. The  power  supply  should  

operate  in  a  vertical position in order to provide free and  convectional  air  flow  through ventilating holes of the 
enclosure.  

 

           The power supply load balance should be done before installation: 

      1. Output current 4x1A + 0,5A battery charging 
      2. Output current 4x0,87A + 2A battery charging  
      Total current of the rec battery is max. 5,5A

*

The    power    supply    is    designed    for    a    continuous    operation    and    is    not    equipped    with    a  

power-switch.  Therefore,  an  appropriate  overload  protection  in  the  power  supply  circuit  should  be  provided. 
Moreover, the user should be informed how to disconnect the power supply unit from the mains supply (usually by 
assigning an appropriate fuse in the fuse box).   The electrical system shall be made in accordance with applicable 
standards and regulations.  

The PSU is designed for 10Mbit/s and 100Mbit/s  Ethernet network (so-called Fast Ethernet)

. However, it 

can  not  be  used  for  a  1000  Mbit/s  network  (so-called  Gigabit  Ethernet).

  Connections  between  the  power 

supply and the camera can be done using UTP-3 cable (networks with data-rates up to 10 Mbit/s) or UTP-5 cable. 
Due to the lower resistance wiring, it is recommended (especially at large distances between the power supply and 
receivers) to use UTP-5 cable also for networks with data-rates up to 10 Mbit/s.  

 

 

                                                 

*

 

See diagram 1

 

Содержание GREEN POWER CCTV POE042455B

Страница 1: ...POE042455B v 1 0 PoE 27 6V 4x1A 2x7Ah PoE power supply with battery backup EN Edition 5 from 16 03 2016 Supersedes the edition 4 from 25 05 2015 GREEN POWER CCTV PoE...

Страница 2: ...upply output 4 2 Battery operation 4 3 Maintenance 1 Technical description 1 1 General description The PSU is designed for supply of up to 4 webcams requiring stabilized voltage of 24V DC 15 The PSU s...

Страница 3: ...ains supply indication input 3 F1 F4 fuses in the AUX1 AUX4 F1A circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L4 voltage indication at the AUX outputs during normal opera...

Страница 4: ...operation of the switch mode PSU 3 V ADJ potentiometer regulation of the power supply output voltage 4 Selection jumper for charging current Ibat 0 5 A Ibat 2 A Description jumper on jumper off Factor...

Страница 5: ...protection SCP and reverse polarity connection melting fuse Overvoltage protection OVP U 115 150 of the output voltage disconnection of the output voltage automatic return Deep discharge battery prot...

Страница 6: ...class with normal relative humidity RH 90 maximum no condensation and temperature range from 10 C up to 40 C The power supply should operate in a vertical position in order to provide free and convec...

Страница 7: ...r an electric shock 4 Connect the network cables Ethernet to the PoE module supply voltage is present only at the AUX sockets and the cameras should be connected to them Pin assignment of the AUX and...

Страница 8: ...the LED is permanently illuminated No DC no DC voltage at the module input is indicated by turning off the LIN LED LFPS red LED Fig 2 component 10 is not illuminated during normal operation no failur...

Страница 9: ...If the PTC polymer fuses are used disconnect the load from the power supply output for approximately 1 minute to restore output voltage the time needed to cool down the PTC fuse In case of melting fus...

Страница 10: ...service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...