Outdoor and Open Vessel Installation
The dBi Series Intelligent Transducer can be simply mounted on a bracket,
suitable for the application and secured using either the 1" BSP/NPT rear
thread or via the 1½″ or 2″ front thread, dependant on model.
Care should be taken to ensure that the dBi Series Intelligent Transducer is
not installed in direct sunlight, to avoid errors in the measurement of
ambient temperature.
Attention should also be taken, when mounting the unit, to ensure that
strong windy conditions are avoided, wherever possible, to prevent
abnormal operation.
DBI MODEL
RANGE
L = BLANKING
dBi 3
3 metres (9.84 feet)
125mm (0.41 feet)
dBi 6
6 metres (19.69 feet)
300mm (0.98 feet)
dBi 10
10 metres (32.18 feet)
300mm (0.98 feet
dBi 15
15 metres (49.21 feet)
500mm (1.64 feet)
‘L’ (Blanking) should, as a minimum be at
least that as detailed in the
table above but can be greater if required.
Mounted via Rear 1″BSP/NPT
Thread
Mounted via optional Front
Thread