www.pulsar.pl
AWZ502
4
Caption:
jumper on,
jumper off
[2]
START button (launching the PSU from a battery)
[3]
STOP button (disconnection of the PSU, starting/finishing the battery test)
[4]
F1 fuse in the battery circuit
[5]
Connectors:
BS - AC absence technical output – OC type (open collector)
hi-Z level = status: failure
L level = status: correct operation
AW- technical output of the PSU operation status – OC type (open collector)
hi-Z level = status: correct operation
L level = status: failure
[6]
LED indicating over voltage protection (UVP) - on
[7]
Connector of the temperature detector
[8]
J1,J2 pins- battery charging current selection
•
J1=
J2=
Ibat =0,6 A
•
J1=
J2=
Ibat =1,2 A
•
J1=
J2=
Ibat =1,8 A
•
J1=
J2=
Ibat =2,4 A
Caption:
jumper on,
jumper off
[9]
P1 output voltage adjustment
[10]
Acoustic indicator
Fig. 2. The view of the PSU pcb.
Table 2. Elements of the PSU (see Fig. 3.)
Element no.
Description
[1]
Isolation transformer
[2]
Pcb of the PSU (Tab. 1, Fig. 2)
[3]
TAMPER x2 micro switches (contacts) of the sabota
ż
e protection (NC)
[4]
F
MAIN
fuse in the battery circuit (230V/AC)
[5]
L-N 230V/AC power supply connector,
PE protection connector
[6]
Battery connBAT = red, -BAT = black
Fig. 3. The view of the PSU.
Содержание AWZ 502
Страница 5: ...www pulsar pl AWZ502 5 ...