background image

4

POOL PUMP SUCTION 
REQUIREMENTS

Pump suction is hazardous and can trap

and drown or disembowel bathers. Do not use or oper-
ate swimming pools, spas, or hot tubs if a suction outlet
cover is missing, broken, or loose.

Follow the guidelines

below for a pump installation which minimizes risk to
users of pools, spas, and hot tubs. 

Entrapment Protection

The pump suction system 

must 

provide protection

against the hazard of 
suction entrapment or hair entrapment/entanglement.

Suction Outlet Covers

All suction outlet covers must be maintained. They must
be replaced if cracked, broken, or missing. 
See below for outlet cover certification requirements.
All suction outlets must have correctly installed, screw-
fastened covers in place.

Testing and Certification

Suction outlet covers must have been tested by a nation-
ally recognized testing laboratory and found to comply
with the lastest ASME/ANSI Specification for 

Suction

Fittings For Use in Swimming Pools, Spas, Hot Tubs, and
Whirlpool Bathtub Applications.

Outlets Per Pump

(see Figure 2)

Provide at least two hydraulically balanced main drains,
with covers, for each swimming pool pump suction line.
The centers of the main drains (suction fittings) must be
at least three feet apart. 
The system must be built so that it cannot operate with
the pump drawing water from only 

one 

main drain (that

is, there must be at least two main drains connected to
the pump whenever it is running). However, if two main
drains run into a single suction line, the single suction
line may be equipped with a valve which will shutoff

both 

main drains from the pump.

More than one pump can be connected to a single suc-
tion line as long as the requirements above are met.

Water Velocity

The maximum water velocity through any suction outlet
must be 1.5 feet per second unless the outlet complies
with the latest ASME/SNSI Specification for 

Suction

Fittings For Use in Swimming Pools, Spas, Hot Tubs, and
Whirlpool Bathtub Applications. 

In any case, do not ex-

ceed the suction fittings maximum designed flow rate.
If 100% of the pump’s flow comes from the main drain
system, the maximum water velocity in the pump suc-
tion hydraulic system must be six feet per second or less
even if one main drain (suction fitting) is completely
blocked. The flow through the remaining main drain(s)
must comply with the latest ASME/ANSI Specification for

Suction Fittings For Use in Swimming Pools, Spas, Hot
Tubs, and Whirlpool Bathtub Applications.

At Least

3 Feet 

Suction Outlet

(Main Drain)

Suction Outlet

(Main Drain)

IAPMO Certified 

Anti-entrapment

Cover or Suction Fitting,

screw-fastened to 

Main Drain Sump

IAPMO Certified 

Anti-entrapment

Cover or Suction Fitting,

screw-fastened to 

Main Drain Sump

Pump

Valves OK between
pump and Tee

No valves between
Tee and Main Drains

2762 0197

Figure 2 – Recommended pump suction layout.

Содержание 71532N

Страница 1: ...el 71532N 71808N 71690N This manual should be furnished to the end user of this pump its use will reduce service calls and chance of injury and will lengthen pump life Arch Chemicals Inc 1200 Lower Ri...

Страница 2: ...ped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and sy...

Страница 3: ...fittings Wrap male pipe threads with one to two layers of Teflon tape Cover entire threaded portion of pipe Do not overtighten or tighten past thread stop in pump port If leaks occur remove pipe clea...

Страница 4: ...ly one main drain that is there must be at least two main drains connected to the pump whenever it is running However if two main drains run into a single suction line the single suction line may be e...

Страница 5: ...ate See Fig 3 use size and type wire required by code Connect motor ground terminal to electrical service ground Ground wire must be a copper conductor It should be the same size as the current carryi...

Страница 6: ...CI in cir cuit it will sense a short circuit to ground and discon nect power before it becomes dangerous to pool users For size of GFCI required and test procedures for GFCI see manufacturer s instruc...

Страница 7: ...2 To prevent pump from freezing drain the pump body through the drain plug Key No 15 Page 11 Clean pump thoroughly 3 Cap inlet piping after drain ing to keep water out of the pipes 4 Be sure motor is...

Страница 8: ...Disconnect power to pump motor Be sure gate valves on suction and return pip ing are closed before starting work Release all pressure by open ing all vents before starting work 1 Drain pump by removi...

Страница 9: ...readed shaft end and shaft shoulder until rubber drive ring hits shaft shoulder NOTICE Be sure not to nick or scratch polished seal face seal will leak if face is damaged 7 Screw impeller onto shaft c...

Страница 10: ...ugh 6 under Removing Old Seal Page 8 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 9 for reassembly 6 Impeller and diffuser may be worn If so order re placement...

Страница 11: ...crew 3 8 16x1 Hex Hd 2 U30 74SS Reducer Bushing 1 U78 820P Decal Suitable for outdoor use U27 635 Decal IMPORTANT Do not use pipe dope WC27 27 Voltage Sticker 230 Volts U27 68 Voltage Sticker 115 230...

Страница 12: ...warranty sets forth Arch s sole obligation and Purchaser s exclusive remedy for defective products ARCH SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGO...

Отзывы: