Pulsar 71532N Скачать руководство пользователя страница 2

2

READ AND FOLLOW

SAFETY 

INSTRUCTIONS!

This is the safety alert symbol. When you see this

symbol on your system or in this manual, look for

one of the following signal words and be alert to the 
potential for personal injury.

warns about hazards that 

will

cause death,

serious personal 
injury, or major property damage if ignored.

warns about hazards that 

can

cause death,

serious personal 
injury, or major property damage if ignored.

warns about hazards that 

will

or 

can

cause

minor personal injury or property damage if ignored.

NOTICE 

indicates special instructions not related to 

hazards.

Carefully read and follow all safety instructions in this
manual and on equipment. 

Keep safety labels in good

condition; replace if missing or damaged.

Incorrectly installed or tested equipment
may fail, causing
severe injury or property damage. 

Read and follow instructions in owner's manual when in-
stalling and operating equipment. Have a trained pool
professional perform all pressure tests.
1. Do not connect system to a high pressure or city water

system.

2. Use equipment only in a pool or spa installation.
3. Install pump with at least 2 hydraulically balanced

main drains equipped with correctly installed, screw-
fastened, anti-entrapment certified covers. See Page 4.

4. Trapped air in system can cause explosion. BE SURE

all air is out of system before operating or testing
equipment.

Before pressure testing, make the following safety
checks:

Check all clamps, bolts, lids, and system accessories be-
fore testing.
Release all air in system before testing.
Tighten trap lids to 30 ft. lbs. (4.1 kg-m) torque for testing.
Water pressure for test must be less than 25 PSI 
(7.5 kg/cm

2

).

Water Temperature for test must be less than 100

o

F

(38

o

C).

Limit test to 24 hours. After test, visually check system to
be sure it is ready for operation. Remove trap lid and
retighten hand tight only.

NOTICE:

These parameters apply to equipment in this

manual only. For other equipment, consult manufacturer.

NOTICE:

For swimming pool circulation use, pump must

be installed with a hair and lint strainer.

IMPORTANT

SAFETY INSTRUCTIONS

Always follow basic safety precautions with this
equipment, including the following.

To reduce the risk of injury, do not per-

mit children to use this product unless they are closely
supervised at all times.

This pump is for use with permanently

installed pools and may also be used with hot tubs
and spas if so marked. Do not use with storable pools.
A permanently installed pool is constructed in or on
the ground or in a building such that it cannot be
readily disassembled for storage. A storable pool is
constructed so that it may be readily disassembled for
storage and reassembled to its original integrity.

SAVE THESE 

INSTRUCTIONS

Содержание 71532N

Страница 1: ...el 71532N 71808N 71690N This manual should be furnished to the end user of this pump its use will reduce service calls and chance of injury and will lengthen pump life Arch Chemicals Inc 1200 Lower Ri...

Страница 2: ...ped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and sy...

Страница 3: ...fittings Wrap male pipe threads with one to two layers of Teflon tape Cover entire threaded portion of pipe Do not overtighten or tighten past thread stop in pump port If leaks occur remove pipe clea...

Страница 4: ...ly one main drain that is there must be at least two main drains connected to the pump whenever it is running However if two main drains run into a single suction line the single suction line may be e...

Страница 5: ...ate See Fig 3 use size and type wire required by code Connect motor ground terminal to electrical service ground Ground wire must be a copper conductor It should be the same size as the current carryi...

Страница 6: ...CI in cir cuit it will sense a short circuit to ground and discon nect power before it becomes dangerous to pool users For size of GFCI required and test procedures for GFCI see manufacturer s instruc...

Страница 7: ...2 To prevent pump from freezing drain the pump body through the drain plug Key No 15 Page 11 Clean pump thoroughly 3 Cap inlet piping after drain ing to keep water out of the pipes 4 Be sure motor is...

Страница 8: ...Disconnect power to pump motor Be sure gate valves on suction and return pip ing are closed before starting work Release all pressure by open ing all vents before starting work 1 Drain pump by removi...

Страница 9: ...readed shaft end and shaft shoulder until rubber drive ring hits shaft shoulder NOTICE Be sure not to nick or scratch polished seal face seal will leak if face is damaged 7 Screw impeller onto shaft c...

Страница 10: ...ugh 6 under Removing Old Seal Page 8 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 9 for reassembly 6 Impeller and diffuser may be worn If so order re placement...

Страница 11: ...crew 3 8 16x1 Hex Hd 2 U30 74SS Reducer Bushing 1 U78 820P Decal Suitable for outdoor use U27 635 Decal IMPORTANT Do not use pipe dope WC27 27 Voltage Sticker 230 Volts U27 68 Voltage Sticker 115 230...

Страница 12: ...warranty sets forth Arch s sole obligation and Purchaser s exclusive remedy for defective products ARCH SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGO...

Отзывы: