3. Storage Instructions
3.1 Short Term
Storage of PULSAR Shadow® pumps for up to 12 months is considered short-term. The
recommended short-term storage procedures are:
1. Store the pump indoors at room temperature in a dry environment.
2. Within two months after date of shipment, fill the eccentric box to its normal operating
level with Pulsalube 9M oil. If required by the operating environment, take any steps
required to prevent entry of water or humid air into the eccentric enclosure.
3. Prior to start up, inspect housing, and gearbox. Replenish eccentric and gearbox oils
as required to maintain operating levels. If water or condensation is present, change
oil as described under Equipment Startup, Section 5.
4. Prior to startup, perform a complete inspection and then start up in accordance with
instructions in this manual.
3.2 Long Term
Every twelve months, in addition to the above short-term procedures, power up the
motor and operate the pump for a minimum of one hour. It is not necessary to have
liquid in the reagent head during this operation, but the suction and discharge ports must
be open to atmosphere.
After twelve months of storage, Pulsafeeder’s warranty cannot cover items that are
subject to deterioration with age such as seals and gaskets. If the pump has been in
storage longer than 12 months it is recommended that such items be inspected and
replaced as necessary prior to startup. Materials and labor to replace this class of item
under these circumstance are the purchaser’s responsibility. For a continuance of the
initial warranty after extended storage, equipment inspection and any required
refurbishing must be done by a Pulsafeeder representative.