10. Troubleshooting
DIFFICULTY
PROBABLE CAUSE
REMEDY
Pump does not start
Faulty power source
Check power source
Blown fuse, circuit breaker overload
Replace - eliminate
Broken wire
Locate and repair
Wired improperly
Check diagram
Process piping blockage
Open valves, clear other obstructions
No delivery
Motor not running
Check power source. Check wiring
diagram (see above)
Supply tank empty
Fill tank
Lines clogged
Clean and flush
Closed line valves
Open valves
Ball check valves held open with solids
Clean - inspect, flush with clear fluid
Vapor lock, cavitation
Increase suction pressure
Prime lost
Re-prime, check for leak
Strainer clogged
Remove and clean. Replace screen if
necessary
Stroke adjustment set at zero
Increase stroke length setting
Low delivery
Motor speed too low
Check voltages, frequency, wiring and
terminal connections. Check
nameplate vs. Specifications
Check valves worn or dirty
Clean, replace if damaged
Calibration system error
Evaluate and correct
Product viscosity too high
Lower viscosity by increasing product
temperature or dilution. Increase
pump and/or piiping size
Product cavitating
Increase suction pressure
Delivery gradually drops
Check valve leakage
Clean, replace if damaged
Leak in suction line
Locate and correct
Strainer fouled
Clean or replace screen
Product change
Check viscosity and other variables
Supply tank vent plugged
Unplug vent