background image

10 

 

end of the pump drive shaft (Item 4) and slide 
the driven magnet assembly (Item 18) off the  
drive shaft. The key (Item 8) and other retaining 
ring can also now be removed. 

 

9.    Remove the housing nuts (Item 16) and the 

rear housing (Item 1). 

 

10.  Remove the center housing (Item 2). The 

gears (Items 6, 7) and wear plates (Item 11) 
are now accessible and can readily be 
removed along with the drive and idler shafts 
(Item 4, 5). 

 

11.  The gears can be removed from the shafts by 

removing one of the retaining rings and sliding 
the gear off the shaft. 

 

12.  Inspect all parts for signs of wear or damage. 

The maximum diametrical clearance (bearing 

J.D. - 

shaft 0.0.) that is acceptable is .010 

inches (.254mm). Shafts and bearings that are 
scored or worn must be replaced. Gears and 
wear plates with excessive wear or scoring  
must also be replaced. 

 

13.  Clean all parts before reassembly. 

REASSEMBLY 

1.    Install the drive and idler gear (Items 6, 7) onto 

their respective shafts (Items 

4, 5) using keys 

(Item 8) and retaining rings (Item 14). Take 
care not to scratch the shafts when installing 
the rings. Check the ends of the rings for sharp 
burrs. If a plastic and metal gear set are being 
used, the plastic gear is always the idler gear. 

 

2.   With the housing pins (Item 13) in the locator 

holes in the front housing (Item 3) and new O- 
rings (Item 12) installed in the center housing, 
assemble on the center housing (Item 2). 

 

3.   Install a pair of wear plates (Item 

11) 

and the 

shaft assemblies. 

 

4.   Next install another pair of wear plates, housing 

pins and the rear housing (Item 

1). 

Install the 

housing bolts (Item 15) and nuts (Item 16) and 
tighten. 

 

5.    Install the following parts onto the pump drive 

shaft in the order listed: retaining ring (Item 14), 
key (Item 8), driven magnet assembly    

   

 

(Item 18) with the short, hub

side towards the front housing and retaining ring. 
(Item 14). Note: Only new retaining rings should 
be used on the driven magnet end due to the 
bending required at disassembly. Use caution 
not to bend these rings during assembly. 

 

6.   Place a new O-ring (Item 28) onto the pilot on 

the front housing and place the can (Item 19) 
over the O-ring. Next pilot the casing (Item 20) 
over the can and thread in hand tight the front   
housing bolts (Item 26). Gradually and evenly 
tighten the front housing bolts to draw the 
casing and front housing together. Take care 
not to pinch the O-ring. Replace the protective 
plugs. 

 

7.    Install the spool (Item 29) onto the motor. 

Then install the drive magnet assembly (Item   
21) onto the motor shaft to the dimension 
shown in Figure 3. If the motor is metric slide 
the drive magnet assembly onto the motor shaft   
until it butts up against the shoulder on the 
motor shaft. Tighten the drive magnet 
setscrews (Item 24) through the hole provided 
in the spool to 75 inch lbs. (847 Ncm). These 
setscrews have a special nylon patch applied to 
the threads to prevent loosening. 

 

8.   Carefully assemble the motor/spool/drive 

magnet assembly to the pump casing. Be 
careful not to chip the drive magnets when 
slipping them over the can or to pinch your 
fingers when the two assemblies snap together.   
The use of (4) assembly guide pins (Part # 
49639) is suggested. Use guide pin (Part # 
49656) for metric motors. See Figure 2.    
Install casing bolts (Item 35). 

 

9.   Reinstall pump in system, open inlet and 

discharge valves and start pump. Monitor pump   
for 5-10 minutes for signs of binding, excessive     
noise and motor amperage draw. Check 
performance. If problems are encountered refer 
to the Troubleshooting Section. 

Содержание Isochem GM12 Series

Страница 1: ...Installation Operation Maintenance Instruction All Models Isochem GEARCHEM PUMPS Bulletin No IOM ISO 4000 Rev B...

Страница 2: ......

Страница 3: ...LATION REMOVAL 12 DISASSEMBLY REASSEMBLY PEDESTAL 13 TROUBLESHOOTING 14 PUMP SPECIFICATION CHART 15 EXPLODED VIEW DRAWING GMH8 SERIES 16 GMC12 SERIES 17 GMC16 SERIES 18 PEDESTALS 19 SIGNIFICANT MODEL...

Страница 4: ...ts which can run decoupled without losing their magnetic strength provided magnet temperature does not exceed 450 F 232 C Note If the pump is allowed to run for an extended period of time decoupled hi...

Страница 5: ...er motor rotation before final piping 4 To check system operation installation of vacuum pressure gauges in the suction and discharge lines is recommended 5 Keep suction lines short and straight to mi...

Страница 6: ...draining of the magnetic coupling area because this area will not self drain There is a drain plug in the front housing for access to this area OPERATION 1 Prior to operation make sure all suction pi...

Страница 7: ...ored to original performance by replacing the idler gear alone Note Extended life bearings must be used only with extended life shafts 1 When changing a pump from one service to another be sure to che...

Страница 8: ...gnets It is difficult to remove small particles and larger objects could be attracted with enough force to break the magnets Be careful during disassembly and reassembly of the drive and driven magnet...

Страница 9: ...s 4 5 11 The gears can be removed from the shafts by removing one of the retaining rings and sliding the gear off the shaft 12 Inspect all parts for signs of wear or damage The maximum diametrical cle...

Страница 10: ...S SD2580 DISASSEMBLY 1 Close discharge and suction valves 2 Disconnect power source to motor 3 Flush and drain pump then remove pump from the piping Do not forget to drain the can area through the fro...

Страница 11: ...the pump drive shaft in the order listed retaining ring Item 14 key Item 8 driven magnet assembly Item 18 with the short hub side towards the front housing and retaining ring Item 14 Note Only new re...

Страница 12: ...em 28 If the pump has the double can option remove the nipples Item 66 first then the double can Item 27 The double can has an integral can ring welded to it Now the containment can Item 26 can be rem...

Страница 13: ...n without binding 9 Reinstall pump in system open inlet and discharge valves and check for leaks Start pump Monitor pump for 5 10 minutes for signs of binding excessive noise and high motor amperage d...

Страница 14: ...part with a screwdriver or hand chisel but this should be done very carefully with only nominal force 3 In most instances the heat transfer cement adheres to the pump and not the inner surfaces of the...

Страница 15: ...riction 5 Thin liquid or accept lower flow 6 Correctly set or repair relief valve 7 Increase suction pressure 8 Inspect and repair as required PUMP GRADUALLY LOSES PRIME 1 Air leak in suction 2 Suctio...

Страница 16: ...15...

Страница 17: ...16...

Страница 18: ...17...

Страница 19: ...18...

Страница 20: ...19...

Страница 21: ...20...

Страница 22: ...21...

Страница 23: ...22...

Страница 24: ...23...

Страница 25: ...24...

Страница 26: ...25...

Страница 27: ...26...

Страница 28: ...27...

Страница 29: ...28...

Страница 30: ...29...

Страница 31: ...30...

Страница 32: ...31...

Страница 33: ...32...

Страница 34: ...33...

Страница 35: ...34...

Страница 36: ...35...

Страница 37: ...36...

Страница 38: ...37...

Страница 39: ...38 Installation Operation Maintenance Instruction All Models Isochem GEARCHEM PUMPS Bulletin No IOM ISO 4000 Rev B ADDENDUM 7 2015...

Страница 40: ...39...

Страница 41: ...40...

Страница 42: ...41...

Страница 43: ...42...

Страница 44: ...43...

Страница 45: ...44...

Страница 46: ...45...

Страница 47: ...46...

Страница 48: ...47...

Страница 49: ...48...

Страница 50: ...49...

Страница 51: ...50...

Страница 52: ...51...

Страница 53: ...52...

Страница 54: ...53...

Страница 55: ...54...

Страница 56: ...55...

Страница 57: ...56...

Страница 58: ...57...

Страница 59: ...58...

Страница 60: ...59...

Страница 61: ...60...

Страница 62: ...61...

Страница 63: ...62...

Страница 64: ...63...

Страница 65: ...64...

Страница 66: ...65...

Страница 67: ...66...

Страница 68: ...67...

Страница 69: ...68...

Страница 70: ...69...

Страница 71: ...70...

Страница 72: ...71...

Страница 73: ...72...

Страница 74: ...73...

Страница 75: ...74...

Страница 76: ...75...

Страница 77: ...76...

Страница 78: ...77...

Страница 79: ...78...

Страница 80: ...79...

Страница 81: ...80...

Страница 82: ...81...

Страница 83: ...82...

Страница 84: ...83...

Страница 85: ...84...

Страница 86: ...85...

Страница 87: ...86...

Страница 88: ...87...

Страница 89: ...88...

Страница 90: ...89...

Страница 91: ...90...

Страница 92: ...91...

Страница 93: ...92...

Страница 94: ...93...

Страница 95: ...94...

Страница 96: ...95...

Страница 97: ...96...

Страница 98: ...97...

Страница 99: ...98...

Страница 100: ...99...

Страница 101: ...100...

Страница 102: ...101...

Страница 103: ...102...

Страница 104: ...103...

Страница 105: ...104...

Страница 106: ...105...

Страница 107: ...106...

Страница 108: ...hem GEARCHEM PUMPS Bulletin No IOM ISO 4000 Rev B All Models Pulsafeeder Inc A unit of IDEX Corporation 2883 Brighton Hnrietta Town Line Road Rochester NY 14623 1 585 292 8000 www pulsa com pulsa idex...

Отзывы: