QS3.241
Q-Series
24V,
3.4A,
S
INGLE
P
HASE
I
NPUT
Jul. 2020 / Rev. 2.3 DS-QS3.241-EN
All parameters are specified at 24V, 3.4A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
4/26
3.
AC-I
NPUT
AC input
nom.
AC 100-240V
suitable for TN-, TT- and IT mains networks
85-276Vac
continuous operation
60-85Vac
full power for 200ms, no damage between 0 and 85Vac
276-300Vac
< 500ms
Allowed voltage L or N to earth
max.
276Vac
continuous, IEC 62103
Input frequency
nom.
50–60Hz
±6%
Turn-on voltage
typ.
61Vac
steady-state value, see Fig. 3-1
Shut-down voltage
typ.
58Vac
steady-state value, see Fig. 3-1
AC 100V
AC 120V
AC 230V
Input current
typ.
1.67A
1.42A
0.82A
at 24V, 3.4A, see Fig. 3-3
Power factor *)
typ.
0.55
0.53
0.47
at 24V, 3.4A, see Fig. 3-4
Crest factor **)
typ.
3.33
3.9
3.88
at 24V, 3.4A
Start-up delay
typ.
360ms
350ms
330ms
Rise time
typ.
6ms
5ms
7ms
0mF, 24V, 3.4A, see Fig. 3-2
typ.
20ms
20ms
22ms
3.4mF, 24V, 3.4A, see Fig. 3-2
Turn-on overshoot
max.
100mV
100mV
100mV
*) The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit.
**) The crest factor is the mathematical ratio of the peak value to RMS value of the input current waveform.
Fig. 3-1
Input voltage range
Fig. 3-2
Turn-on behavior, definitions
Tur
n-
on
85V
Rated
input range
max.
500ms
V
IN
P
OUT
60V
300Vac
276V
Shut
-down
full
power
for
200ms
Start-up
delay
Rise
Time
O
ve
rs
hoot
- 5%
Output
Voltage
Input
Voltage
Fig. 3-3
Input current vs. output load at 24V
Fig. 3-4
Power factor vs. output load
0.5
1.5
1.0
2.0
2.5
3.0 3.5A
0
0.3
0.6
0.9
1.2
1.5
1.8A
Output Current
Input
Current, typ.
230V
ac
120V
ac
100V
ac
Power
Factor, typ.
0.5
1.0
1.5
2.0
3.5A
0.35
0.4
0.45
0.5
0.55
0.6
Output Current
120V
ac
230Vac
2.5
3.0
100V
ac