UZK12.261, UZO12.26
U-Series
B
ATTERY
M
ODULE
12V,
26AH
Mar. 2019 / Rev. 2.2a DS-UZK12.261
All parameters are typical values specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
5/10
10.
I
NSTRUCTIONS FOR
R
EPLACING
B
ATTERIES
Batteries need to be replaced periodically. The time interval depends on the ambient temperature in which the battery
is used and on the number and depth of discharge cycles.
Disconnect battery fuse before replacing the battery.
Regarding disposal of used batteries see chapter 6.
Fig. 10-1
Replacing the battery
To replace battery:
1) Loosen screw with only one turn.
2) Unscrew the battery terminals.
3) Slide the mounting bracket sideways and
take the mounting bracket off.
4) Remove the battery.
5) To insert the new battery use same
procedure vice versa.
Do not over-tighten screws of the terminal
bolts of the battery. Recommended
tightening torque: 3Nm (26lb.inch).