Page 9
AccuPiXEL Series Camera Serial Commands
AccuPiXEL Series Camera-Control Software
TABLE 3.
Function Flag Description 1
SHTR2FLG (Bit3) -- 00 - (0) no shutter, 01 - (1) normal shutter
SHTR1FLG (Bit2) -- 10 - (2) direct shutter, 11- (3) async shutter
MSEL2FLG (Bit1) -- 00 - (0) normal scan, 01 - (1) partial scan #1 (optional)
MSEL1FLG (Bit0) -- 10 - (0) normal scan, #2 (optional), 11-(3) two-row scan
TABLE 4.
Function Flag Description 2
TSELFLG (Bit4) -- 0 - Select table A, 1 - Select table B
LUTB2FLG (Bit3) -- 00 - Linear mode; 01 - Knee mode (for table B)
LUTB1FLG (Bit2) --10 - Gamma mode; 11 - Direct input mode (reserved)
LUTA2FLG (Bit1) -- 00 - Linear mode; 01 - Knee mode (for table A)
LUTA1FLG (Bit0) -- 10 - Gamma mode; 11 - Direct input mode (reserved)
Byte 12
FUNCFLAG1 (1 byte)
--
function flag #1
Byte 13
FUNCFLAG2 (1 byte)
--
function flag #2
Byte 14
SHTRNUM (1 byte)
--
current shutter number
Byte 15, 16
SHTRVAL (2 byte)
--
manual/direct shutter value
BIT
7
6
5
4
3
2
1
0
FUNCFLAG #1
Resv
Resv
Resv
Resv
SHTR2FLG
SHTR1FLG
MSEL2FLG
MSEL1FLG
BIT
7
6
5
4
3
2
1
0
FUNCFLAG #2
TSELFLG
LUTB2FLG
LUTB1FLG
LUTA2FLG
LUTA1FLG
TABLE 2.
16 Bytes Status Report (Continued)