WARNING!
Important safety instructions. Carefully read
visibly identified in compliance with the provisions of
mesh correctly with 2 mm of play along the full length of
and comply with all the warnings and instructions that
standard EN 13241-1.
the rack; keep the track the gate slides on clean and free of
come with the product as incorrect installation can cause
- Once installation is complete, apply a nameplate
debris at all times.
injury to people and animals and damage to property.
featuring the door/gate’s data.
- For sliding gates and doors only: make sure the gate’s
The warnings and instructions give important information
- This product cannot be installed on leaves incorporating
running track is straight and horizontal and that the
regarding safety, installation, use and maintenance. Keep
doors (unless the motor can be activated only when the
wheels are strong enough to take the weight of the gate.
hold of instructions so that you can attach them to the
door is closed).
- For cantilever sliding gates only: make sure there is no
technical file and keep them handy for future reference.
- If the automated system is installed at a height of less
dipping or swinging during operation.
than 2.5 m or is accessible, the electrical and mechanical
- For swing gates only: make sure the leaves’ axis of
GENERAL SAFETY
parts must be suitably protected.
rotation is perfectly vertical.
This product has been designed and built solely for the
For roller shutter automation only:
-For barriers only: before opening the door, the spring
purpose indicated herein.
1) The motor’s moving parts must be installed at a height
must be decompressed (vertical boom).
Uses other than those indicated herein might cause
greater than 2.5 m above the floor or other surface from
- Check that all safety devices (photocells, safety edges,
damage to the product and create a hazard.
which they may be reached.
etc.) are working properly and that the anti-crush safety
- The units making up the machine and its installation
2) The gearmotor must be installed in a segregated and
device is set correctly, making sure that the force of impact
must meet the requirements of the following European
suitably protected space so that it cannot be reached
measured at the points provided for by standard EN 12445
Directives, where applicable: 2006/42/EC, 2014/35/EC,
without the aid of tools.
is lower
2014/30/EC, and later amendments. For all countries
- Install any fixed controls in a position where they will not
than the value laid down by standard EN 12453.
outside the EEC, it is advisable to comply with the
cause a hazard, away from moving parts. More specifically,
- Impact forces can be reduced by using deformable
standards mentioned, in ad-
hold-to-run controls must be positioned within direct
edges.
dition to any national standards in force, to achieve a good
sight of the part being controlled and, unless they are key
- Make sure that the emergency operation works, where
level of safety.
operated, must be installed at a height of at least 1.5 m
this feature is provided.
- The Manufacturer of this product (hereinafter referred to
and in a place where they cannot be reached by the
- Check opening and closing operations with the control
as the “Firm”) disclaims all responsibility resulting from
public.
devices applied.
improper use or any use other than that for which the
- Apply at least one warning light (flashing light) in a
- Check that electrical connections and cabling are intact,
product has been designed, as indicated herein, as well as
visible position, and also attach a Warning sign to the
making extra sure that insulating sheaths and cable glands
for failure to apply Good Practice in the construction of
structure.
are undamaged.
entry systems (doors, gates, etc.) and for deformation that
- Attach a label near the operating device, in a permanent
- While performing maintenance, clean the photocells’
could occur during use.
fashion, with information on how to operate the
optics.
- Installation must be carried out by qualified personnel
automated system’s manual release.
- When the automated system is out of service for any
(professional installer, according to EN 12635), in
- Make sure that, during operation, mechanical risks are
length of time, activate the
compliance with Good Practice and current code.
avoided or relevant protective measures taken and, more
emergency release (see “EMERGENCY OPERATION” section)
- Before installing the product, make all structural changes
specifically, that nothing can be banged, crushed, caught
so that the operated part is made idle, thus allowing the
required to produce safety gaps and to provide protection
or cut between the part being operated and surrounding
gate to be opened and closed manually.
from or isolate all crushing, shearing and dragging hazard
parts.
- If the power cord is damaged, it must be replaced by the
areas and danger zones in general in accordance with the
- Once installation is complete, make sure the motor
manufacturer or their technical assistance department or
provisions of standards EN 12604 and 12453 or any local
automation settings are correct and that the safety and
other such qualified person to avoid any risk.
installation standards.
release systems are working properly.
- If “D” type devices are installed (as defined by En12453),
Check that the existing structure meets the necessary
- Only use original spare parts for any maintenance or
connect in unverified mode, foresee mandatory
strength and stability requirements.
repair work. The Firm disclaims all responsibility for the
maintenance at least every six months
- Before commencing installation, check the product for
correct operation and safety of the automated system if
- The maintenance described above must be repeated at
damage.
parts from other manufacturers are used.
least once yearly or at shorter intervals where site or
- The Firm is not responsible for failure to apply Good
- Do not make any modifications to the automated
installation conditions make this necessary.
Practice in the construction and maintenance of the doors,
gates, etc. to be motorized, or for deformation that might
system’s components unless explicitly authorized by the
WARNING!
Firm.
Remember that the drive is designed to make the
occur during use.
- Instruct the system’s user on what residual risks may be
gate/door easier to use and will not solve problems as a
- Make sure the stated temperature range is compatible
encountered, on the control systems that have been
result of defective or poorly performed installation or lack
with the site in which the automated system is due to be
applied and on how to open the system manually in an
of maintenance
installed.
emergency. give the user guide to the end user.
- Do not install this product in an explosive atmosphere:
SCRAPPING
- Dispose of packaging materials (plastic, cardboard,
the presence of flammable fumes or gas constitutes a
Materials must be disposed of in accordance with the
polystyrene, etc.) in accordance with the provisions of the
serious safety hazard.
regulations in force. There are no particular hazards or risks
laws in force. Keep nylon bags and polystyrene out of
- Disconnect the electricity supply before performing any
involved in scrapping the automated system. For the
reach of children.
work on the system.
purpose of recycling, it is best to separate dismantled parts
Also disconnect buffer batteries, if any are connected.
WIRING
into like materials (electrical parts - copper - aluminium -
- Before connecting the power supply, make sure the
WARNING!
For connection to the mains power supply,
plastic - etc.).
product’s ratings match the mains ratings and that a
use: a multicore cable with a cross-sectional area of at least
DISMANTLING
suitable residual current circuit breaker and overcurrent
5x1.5mm 2 or 4x1.5mm 2 when dealing with threephase
If the automated system is being dismantled in order to be
protection device have been installed upline from the
power supplies or 3x1.5mm 2 for single-phase supplies
reassembled at another site, you are required to:
electrical system. Have the automated system’s mains
(by way of example, type H05 VV-F cable can be used with
- Cut off the power and disconnect the whole electrical
power supply fitted with a switch or omnipolar thermal-
a cross-sectional area of 4x1.5mm 2 ). To connect auxiliary
system.
magnetic circuit breaker with a contact separation that
equipment, use wires with a cross-sectional area of at least
- Remove the actuator from the base it is mounted on.
meets code
0.5 mm 2 .
- Remove all the installation’s components.
requirements.
- Only use pushbuttons with a capacity of 10A-250V or
- See to the replacement of any components that cannot
- Make sure that upline from the mains power supply there more.
be removed or happen to be damaged.
is a residual current circuit breaker that trips at no more
- Wires must be secured with additional fastening near the
than 0.03A as well as any other equipment required by
terminals (for example, using cable clamps) in order to
THE DECLARATION OF CONFORMITY CAN BE VIEWED
code.
keep live parts well separated from safety extra low
ON THIS WEBSITE:
- Make sure the earth system has been installed correctly:
voltage parts.
WWW.automatismospujol.com
earth all the metal parts belonging to the entry system
- During installation, the power cable must be stripped to
(doors, gates, etc.) and all parts of the system featuring an
allow the earth wire to be connected to the relevant
earth terminal.
terminal, while leaving the live wires as short as possible.
Anything that is not explicitly provided for in the
- Installation must be carried out using safety devices and
The earth wire must be the last to be pulled taut in the
installation manual is not allowed. The operator’s proper
controls that meet standards EN 12978 and EN 12453.
event the cable’s fastening device comes loose.
operation can only be guaranteed if the information
- Impact forces can be reduced by using deformable
WARNING! safety extra low voltage wires must be kept
given is complied with. The Firm shall not be answerable
edges.
physically separate from low voltage wires.
for damage caused by failure to comply with the
- In the event impact forces exceed the values laid down
Only qualified personnel (professional installer) should be
instructions featured herein.
by the relevant standards, apply electro-sensitive or
allowed to access live parts.
While we will not alter the product’s essential features, the
pressure-sensitive devices.
CHECKING THE AUTOMATED SYSTEM AND
Firm reserves the right, at any time, to make those changes
- Apply all safety devices (photocells, safety edges, etc.)
MAINTENANCE
deemed opportune to improve the product from a
required to keep the area free of impact, crushing,
Before the automated system is finally put into operation,
technical, design or commercial point of view, and will not
dragging and shearing hazards. Bear in mind the
and during maintenance work, perform the following
be required to update this publication accordingly.
standards and directives in force, Good Practice criteria,
checks meticulously:
intended use, the installation environment, the operating
- Make sure all components are fastened securely.
logic of the system and forces generated by the
- Check starting and stopping operations in the case of
automated system.
manual control.
- Apply all signs required by current code to identify
- Check the logic for normal or personalized operation.
hazardous areas (residual risks). All installations must be
- For sliding gates only: check that the rack and pinion
INSTALLER WARNINGS