mini marathon
automatismos
pujol
- 34 -
english
SELECTING THE TYPE OF OPERATION
Microswitch no. 2 allows the selection of the type of operation.
Switch 2 OFF, mode A
. There is no pre-warning on the flash light lamp before beginning the maneuver.
. Each operation on the maneuver input causes it to be reversed
. The close safety causes re-opening.
Switch 2 ON, mode B
. Flash light lamp pre-warning before each maneuver.
. Close safety causes a slight delay and delays the door.
. Incorporation of alternative maneuver.
TERMINALS DESCRIPTION
1.
Ground (Mesh)
2.
Aerial (Live)
3.
Alternative pushbutton (N.O.)
4.
Safety position (N.C.) (photocell)
5.
Pushbuttons and photocell common wire
6.
Open pushbutton (N.O.)
7.
Close pushbutton (N.O.)
8.
Photocell test
9.
Safety position 1 (N.C.) / 8.2 KOhm range
10.
0 Volt complementary power supply
11.
24 Volt complementary power supply
12.
Battery charger
13.
Flash light position. Free of tension
14.
Flash light position. Free of tension
15.
220V Garage light output
16.
220V Garage light output
17.
220V AC Power supply
18.
220V AC Power supply
19.
24 Volt AC Power supply
20.
24 Volt AC Power supply
21.
Safety device (N.C.) Motor
22.
Motor common safety device
23.
Sensor power supply, positive (brown)
24.
Sensor signal (green)
25.
Sensor power supply, negative (white)
26.
Motor (blue)
27.
Motor (red)
28.
220V (primary of the transformer)
29.
220V (primary of the transformer)
Note:
N.O. Normally Open
N.C. Normally Closed
FUNCTIONS OF THE DIP-SWITCHES
DIP-1
ON
-
The board closes automatically
OFF
-
There is no automatic close
DIP-2
ON
-
Operation mode B
OFF
-
Operation mode A
DIP-3
ON
-
Changes motor direction
OFF
-
Motor direction is the stated one
DIP-4
ON
-
Terminal 9 acts as a safety band
OFF
-
Terminal 9 acts as safety position 1
DIP-5
ON
-
Photocell test disabled
OFF
-
Photocell test enabled
DIP-6
ON
-
Programming via radio enabled
OFF
-
Programming via radio disabled
DIP-7
ON
-
Pedestrian opening
OFF
-
Normal opening
DIP-8
ON
-
Variable smooth stop programming (variable slow down)
OFF
-
Smooth stop set at 20cm (slow down at 20cm)