32 

Rev 1.2 7/15 

 

 

Network Connection 

1.

 

Operating Environment 

Operating System: Windows 2000/2003/XP/Vista/7/8.1 

Network Protocol: TCP/IP 

Client PC: P4/128M RAM/40G HD/ support for scaled graphics card, support for DirectX8.0 or more advanced version. 

2.

 

Equipment Installation 

1) Connect camera to your network via a CAT5 or CAT6 patch cable or directly to your PC via a CAT5 or CAT6 crossover 

cable. 

2) Turn on camera power. 

3) If successful, the orange network light will illuminate and the green light will start flashing. If unsuccessful, the patch 

cable is bad, you are using the wrong cable (patch 

aka “straight-thru”

 cable for connection through a LAN; crossover for a 

direct PC connection) or you have connected to an inactive network jack. 

3.

 

Network Connection 

Connection method between network camera and computer, as in pictures 1.1 and 1.2, below: 

Содержание 12X-USB

Страница 1: ...Rev 1 2 7 15 PTZ Optics 12X USB User Manual V1 2 English...

Страница 2: ...t the camera to rain or moisture Don t remove the cover Removal of the cover may result in an electric shock In case of abnormal operation contact the manufacturer Never operate outside of the specifi...

Страница 3: ...4 Features 4 5 Product Specifications 5 6 Main Unit 7 7 IR Remote Controller Explanation 8 8 Using the IR Remote Controller 10 9 RS 232 Interface 13 10 Serial Communication Control Command Listings 1...

Страница 4: ...C with a maximum current supply of 2A Polarity of the power supply plug is critical and is as follows Handling Avoid any stress vibration or moisture during transportation storage installation and ope...

Страница 5: ...2 Rev 1 2 7 15 Quick Start Step 1 Please check that all connections are correct before powering on the camera...

Страница 6: ...the camera off VIDEO SYSTEM 0 8 1 9 2 1080i60 A 3 1080i50 B 4 720p60 C 5 720p50 D 576i 6 1080p30 E 480i 7 1080p25 F Step 4 Press the Switch ON button on the rear of the camera the power lamp will ill...

Страница 7: ...m output frame rate of 60 fps frames per second 5 Includes a Olympus high quality telephoto lens supporting 12x optical zoom and 16x digital zoom 6 The high SNR signal to noise ratio of the CMOS senso...

Страница 8: ...duction 2D 3D Digital Noise Reduction Video S N 55dB Horizontal Angle of View 6 9 72 5 Vertical Angle of View 3 9 44 8 Horizontal Pan Range 170 Vertical Tilt Range 30 to 90 Pan Speed Range 1 7 100 s T...

Страница 9: ...00m Protocols VISCA Pelco D Pelco P Power Connector JEITA type DC IN 12V Input Voltage 12VDC 10 8 13 0V DC Current Consumption 2 0A Max Operating Temperature 23 F 104 F 5 c 40 c Storage Temperature 4...

Страница 10: ...Network IP streaming and control 2 CVBS composite video SD Interface 8 HDMI 1 3 Digital Video Output 3 System select dial resolution 9 USB 3 0 USB Video Output 4 RS485 jack 10 DC 12V power jack 5 RS2...

Страница 11: ...ng numeric key preset position Clear preset Erase a preset position CLEAR PRESET Numeric button 0 9 Erases a corresponding numeric key preset Or CLEAR PRESET Erases all of the presets simultaneously 4...

Страница 12: ...nd tilting of the lens Press HOME button to face the camera back to front 9 Menu Setting Menu button Press this button to enter or exit the OSD menu 10 Zoom Buttons Zoom Zoom In on subject for narrowe...

Страница 13: ...ired do it in sequence not simultaneously For example F1 means press first and then press and then press F1 1 Pan Tilt Control Tilt up Press Tilt down Press Pan left Press Pan right Press Face the cam...

Страница 14: ...ht Switch BLC ON OFF Press this button to enable the backlight compensation Press it again to disable the backlight compensation Note Backlight is only effective in full auto exposure mode 5 Presets S...

Страница 15: ...ton corresponding to the camera with the IR address that you want to operate This allows for up to 4 cameras to be operated via the same IR remote in the same room 8 Camera IR Address Set Press 3 butt...

Страница 16: ...3 TXD 4 GND 4 DTR 5 RXD 5 GND 6 GND 6 DSR 7 IR OUT 7 RTS 8 NC 8 CTS 9 RI For Control Daisy Chain 1st Camera 2nd Camera Mini DIN 1 DTR 1 DTR 2 DSR 2 DSR 3 TXD 3 TXD 4 GND 4 GND 5 RXD 5 RXD 6 GND 6 GND...

Страница 17: ...85 Half duplex mode with support for VISCA Pelco D or Pelco P protocol The parameters of RS485 are as follows Baud rate 2400 4800 or 9600 bps Start bit 1 bit Data bit 8 bits Stop bit 1 bit Parity bit...

Страница 18: ...0 60 03 FF Indicates that two sockets are already being used executing two commands and the command could not be accepted when received Command Canceled z0 6y 04 FF y Socket No Returned when a command...

Страница 19: ...08 03 FF Far Variable 8x 01 04 08 2p FF p 0 low 7 high Near Variable 8x 01 04 08 3p FF Direct 8x 01 04 48 0p 0q 0r 0s FF pqrs Focus Position Auto Focus 8x 01 04 38 02 FF AF On Off Manual Focus 8x 01 0...

Страница 20: ...0B 03 FF Direct 8x 01 04 4B 00 00 0p 0q FF pq Iris Position CAM_Gain Reset 8x 01 04 0C 00 FF Gain Setting Up 8x 01 04 0C 02 FF Down 8x 01 04 0C 03 FF Direct 8x 01 04 0C 00 00 0p 0q FF pq Gain Position...

Страница 21: ...4 3F 00 pp FF pp Memory Number 0 to 127 Set 8x 01 04 3F 01 pp FF Recall 8x 01 04 3F 02 pp FF CAM_LR_Reverse On 8x 01 04 61 02 FF Image Flip Horizontal On Off Off 8x 01 04 61 03 FF CAM_PictureFlip On 8...

Страница 22: ...ettingReset Reset 8x 01 04 A0 10 FF Reset Factory Setting CAM_Brightness Direct 8x 01 04 A1 00 00 0p 0q FF pq Brightness Position CAM_Contrast Direct 8x 01 04 A2 00 00 0p 0q FF pq Contrast Position CA...

Страница 23: ...l CAM_RGainInq 8x 09 04 43 FF y0 50 00 00 0p 0q FF pq R Gain CAM_BGainInq 8x 09 04 44 FF y0 50 00 00 0p 0q FF pq B Gain CAM_AEModeInq 8x 09 04 39 FF y0 50 00 FF Full Auto y0 50 03 FF Manual y0 50 0A F...

Страница 24: ...ory number last operated SYS_MenuModeInq 8x 09 06 06 FF y0 50 02 FF On y0 50 03 FF Off CAM_LR_ReverseInq 8x 09 04 61 FF y0 50 02 FF On y0 50 03 FF Off CAM_PictureFlipInq 8x 09 04 66 FF y0 50 02 FF On...

Страница 25: ...9 00 03 FF y0 50 01 FF C Type y0 50 02 FF M Type y0 50 03 FF S Type CAM_DateInq 8x 09 00 04 FF y0 50 0r ss uu uu vv ww 0D FF Version dater Big Version Numbers Little Version Numberuuuu Yearvv Monthww...

Страница 26: ...nd List Command Command packed Inquiry Packet Comments CAM_LensBlockInq 8x 09 7E 7E 00 FF y0 50 0u 0u 0u 0u 00 00 0v 0v 0v 0v 00 0w 00 FF uuuu Zoom Position vvvv Focus Position w bit0 Focus Mode 1 Aut...

Страница 27: ...50 00 00 00 00 00 00 00 0p 0q rr 0s 0t 0u FF p AF sensitivity q bit0 Picture flip 1 On 0 Off rr bit6 3 Color Gain 0h 60 to Eh 200 s Flip 0 Off 1 Flip H 2 Flip V 3 Flip HV t bit2 0 NR2D Level u Gain Li...

Страница 28: ...M Set Preset 0xFF Address 0x00 0x03 0x00 Preset ID SUM Clear Preset 0xFF Address 0x00 0x05 0x00 Preset ID SUM Call Preset 0xFF Address 0x00 0x07 0x00 Preset ID SUM Auto Focus 0xFF Address 0x00 0x2B 0x...

Страница 29: ...t Preset 0xA0 Address 0x00 0x03 0x00 Preset ID 0xAF XOR Clear Preset 0xA0 Address 0x00 0x05 0x00 Preset ID 0xAF XOR Call Preset 0xA0 Address 0x00 0x07 0x00 Preset ID 0xAF XOR Auto Focus 0xA0 Address 0...

Страница 30: ...compensation mode Optional items On Off Effective only in Auto mode ExpComp Exposure compensation value Optional items 7 7 Effective only when ExpCompMode is On Backlight Set the backlight compensatio...

Страница 31: ...or One Push ok Manual RG Red gain Optional items 0 255 Effective only in Manual mode BG Blue gain Optional items 0 255 Effective only in Manual mode RG Tuning Red gain fine tuning Optional items 10 10...

Страница 32: ...SpeedByZoom The depth of field scale switch Optional items On Off AF Zone Auto focusing area Optional items Top Center Bottom AF Sense Automatic focusing sensitivity options Optional items Low Normal...

Страница 33: ...ess Decided according to the argument AUTO VISCA Optional items 1 7 P_D_Address PELCO D address Optional items 0 254 P_P_Address PELCO P address Optional items 0 31 V_AddrFix Lock IR Address from chan...

Страница 34: ...the following figure Restore Reset all settings to factory default settings Optional items Yes No Note Press HOME button to confirm All parameters are then restored to default values including IR Remo...

Страница 35: ...AT6 patch cable or directly to your PC via a CAT5 or CAT6 crossover cable 2 Turn on camera power 3 If successful the orange network light will illuminate and the green light will start flashing If uns...

Страница 36: ...33 Rev 1 2 7 15 Picture 1 1 Direct connections via cross over network cable Picture 1 2 Connections to LAN via patch cable to LAN wall jack or LAN switch...

Страница 37: ...downloads web site Run upgrade exe Click the Search tab Click the Search Button The software will show the camera s IP address subnet mask network gateway and the camera s MAC address as shown below I...

Страница 38: ...35 Rev 1 2 7 15...

Страница 39: ...ects these networks NOTE Camera s Factory Default IP Address and Login IP 192 168 100 88 User name admin Password admin 2 Accessing the IP Camera 2 1 Input http your IP address where your IP address i...

Страница 40: ...the free VLC player software Please go to http www videolan org vlc Click the download VLC button If a download window appears click Save Then install the VLC player software by executing the file fr...

Страница 41: ...edia player monitoring 1 VLC media player procedure 1 1 Install the free VLC Media Player software be sure to get appropriate version for your OS Windows MAC http www videolan org vlc index html 1 2 O...

Страница 42: ...39 Rev 1 2 7 15...

Страница 43: ...sed upon video resolution the higher the resolution is the bigger the playing area is Double click the viewing window and it will show in full screen Double click again and it will return to the initi...

Страница 44: ...4 PTZ Speeds Tilt speed can be set at any rate between 1 24 Pan speed can be set at any rate between 1 20 Zoom and Focus speeds can be set at any rate between 0 7 5 PTZ Presets After manually setting...

Страница 45: ...change the language of the menu 1 Media 1 1 Video Setup Click Video The streaming parameters may now be set in the right side area The camera can send 2 simultaneous streams For example one in HD and...

Страница 46: ...PAL and 60HZ NTSC and Dial Priority see rotary dial on camera formats 60Hz is used for North America Video Coding Support both baseline and mainprofile formats for H 264 video encoding Baseline is typ...

Страница 47: ...ame interval Affects the quality of the video compression This setting defines how many predicted frames will be used for each actual frame from 2 150 Shorter intervals increase video quality at the c...

Страница 48: ...on the right shows the corresponding numerical value The Default setting is 43 Saturation Color Saturation 0 100 Use the slider control The box on the right shows the corresponding numerical value Th...

Страница 49: ...n the right shows the corresponding numerical value The Default setting is 0 Flip Mirror Check the Flip box to invert the image vertically for a ceiling mount Check the Mirror box to invert the image...

Страница 50: ...the Cancel button to leave settings unchanged 1 4 System Settings Click System The system parameters may now be set in the right side area 1 Initialize Work Mode RTSP Real Time Streaming Protocol is t...

Страница 51: ...device can be set here The Default the IP address of the camera is 192 168 100 88 The MAC address can be modified but should be left as set by the factory Please note that after changing the IP settin...

Страница 52: ...RTSP streaming protocol The default port 554 PTZ Port Supports camera control via the TCP protocol The default port 5678 Apply and Cancel Buttons After modifying the parameters press the Apply button...

Страница 53: ...server The default port number is 1259 When client and server set up a UDP connection the client sends PTZ command to the internal server and the server will then parse and execute the PTZ commands Th...

Страница 54: ...1 06 01 VV WW 03 02 FF Left 8x 01 06 01 VV WW 01 03 FF Right 8x 01 06 01 VV WW 02 03 FF Upleft 8x 01 06 01 VV WW 01 01 FF Upright 8x 01 06 01 VV WW 02 01 FF DownLeft 8x 01 06 01 VV WW 01 02 FF DownRig...

Страница 55: ...speed Parameter Descriptions Camera IP camera IP address action including up down left right ptzstop pan speed 1 low speed 24 high speed tilt speed 1 low speed 20 high speed Zoom control URLformat as...

Страница 56: ...Wide Variable 81 01 04 07 3P FF Focus Stop 81 01 04 08 00 FF Far Standard 81 01 04 08 02 FF Near Standard 81 01 04 08 03 FF Far Variable 81 01 04 08 2P FF P 0 low speed 7 high speed Near Variable 81 0...

Страница 57: ...cmd action zoom speed Camera IP This camera s IP address action including zoomin zoomout zoomstop zoom speed 0 low speed 7 high speed Focus Control URLformat as below http Camera IP cgi bin ptzctrl cg...

Страница 58: ...body Use a soft dry lint free cloth to clean the lens If the camera is very dirty clean it with a diluted neutral detergent Do not use any type of solvent or harsh detergent which may damages the sur...

Страница 59: ...tele zoom zoomed in settings Control IR remote controller does not control the camera 1 Does one of the 4 Camera Select buttons top row of remote light up when you press any button on the remote 1 If...

Страница 60: ...ually have the full 5Gbps bandwidth required for uncompressed HD video so check bandwidth specs Always connect the HuddleCam directly to the device in order to associate the UVC drivers before attempt...

Страница 61: ...zed the PTZ Optics as an imaging device in which case you may see a new unknown device Westbridge or CYTFX3 labeled device show up in Device Manager s Universal Serial Bus Controllers section rather t...

Страница 62: ...functional USB 3 0 device PTZ Optics Copyright Notice The entire contents of this manual whose copyright belongs to PTZ Optics may not be cloned copied or translated in any way without the explicit p...

Отзывы: