Use the IN5130 overhead blower in proximity to a
static sensitive area or object. The unit can be mounted
on the workstation or attached to a structure using the
mounting holes provided.
Mounting
Install the overhead ionizer 24” (60.9 cm) above
the work area to achieve the most uniform decay per-
formance.
The IN5130 mounts easily using the S-hooks sup-
plied. Chain or cable is not supplied and may be re-
quired. S-hooks attach to the unit. Chains can be easily
attached and mounted to the ceiling or other structure.
Power Connection
Connect the IEC Cable to the main unit, and plug it in
an AC socket.
(Caution: Use the appropriate IEC
cable for the country of use)
.
Make certain the unit is grounded (Via IEC cable).
Turn the unit on to start the corona process. The ion-
izer creates a continuous stream of positive and
negative air ions. The ionized airflow is directed
through the front grill. Charged objects in the ioniza-
tion area are rapidly neutralized .
The ion airflow is adjustable using the fan speed con-
trol knob.
Caution
!
Do not use this ionizer in an explosive environ-
ment! Corona ionizers produce a weak plasma
that can cause ignition in explosive environ-
ments.
3