background image

 

 

 

INSTRUCTIONS

 

Operation/Maintenance  

Aerostat XC™ Ionizing Air Blower 

 

 

 

 

 

2257 North Penn Road 
Hatfield, PA 19440 
(215) 997-0590 
(800) 538-0750 
Fax:  (215) 997-3450 
 
Publication 5100550 rev F 
February, 2002 
 

 

SIMCO’s Aerostat XC was designed for use with sensitive electronic components where 
electrostatic discharge (ESD) is a problem. It can be applied in inspection, testing, and 
assembly environments. The Aerostat XC can also be used where static electricity causes 
problems such as attraction of dirt to product, misalignment of small parts due to electrostatic 
"jumping", and undesirable adhesion of plastic films due to electrostatic charge. 

 
SECTION 1  Description 

SECTION 2  Features 

SECTION 3  Specifications 

SECTION 4  Safety 

SECTION 5  Installation 

SECTION 6  Operation 

SECTION 7  Maintenance 

SECTION 8  Replacement Parts 

SECTION 9  Warranty 

 

Содержание 4002612

Страница 1: ...roblem It can be applied in inspection testing and assembly environments The Aerostat XC can also be used where static electricity causes problems such as attraction of dirt to product misalignment of...

Страница 2: ...el ion emitters which results in an intense alternating electric field at the tip of the emitters It is this intense electric field that introduces alternating polarity ions into the air flow The shap...

Страница 3: ...enter line of air stream Air Flow Characteristics 3 x 6 Area Coverage Heated Air Temperature Fan Speed Above Ambient where applicable Low 11 F 6 C Medium 9 5 C High 7 F 4 C Measured 6 in front of unit...

Страница 4: ...rom 1000 volts to 100 volts Note Discharge times for high speed are 10 longer for 230 V 50 Hz SECTION 4 Safety 4 1 Read all instructions before proceeding with installation or operation Failure to fol...

Страница 5: ...s an optional air filter kit part number 5050281 is available The air filter kit contains user installed brackets and an air filter that can be cleaned and reused The Aerostat XC should be placed appr...

Страница 6: ...neutralize each other Positive and negative ions are electrostatically attracted to each other When they contact the charge transfers and the ions recombine With high air velocity the ions travel furt...

Страница 7: ...s stubborn wash the filter in mild soap and water then rinse Blot the filter dry with paper towels and allow to dry Reinstall filter on air inlet by sliding it under brackets from rear of the unit IMP...

Страница 8: ...on Balance in Section 3 Specifications Do not try to determine ion balance by holding a static meter in the ionized air stream This will result in a meaningless reading 7 6 Calibration The Aerostat XC...

Страница 9: ...eater ionizer and brush 6 4670700 Brush 7 4401510 Ionizer Duct Standoff 2 required 8 4103940 Line Cord Assembly 120 V 8 4104035 Line Cord Assembly 230 V 9 4610699 Illuminated Rocker Switch 120 V 9 461...

Страница 10: ...where state laws override This warranty extends to the original purchaser and is not transferable No person agent distributor dealer or company is authorized to change modify or amend the terms of thi...