background image

SECTION 9  Warranty 
 

SIMCO warrants its products to be free of defects in components, workmanship, or 
materials for a period of one year from date of purchase.  This warranty does not apply 
to any physical or electrical damage caused by misuse, abuse or negligence (such as 
any modifications made to the unit or service work done by any other than SIMCO 
authorized technicians). Any unit with altered or removed serial number is ineligible for 
warranty. 
 
SIMCO will not be liable for loss or damage due directly or indirectly to an occurrence 
or use for which the product is not designed or intended.  In no event shall SIMCO be 
liable for incidental or consequential damages except where state laws override. 
 
This warranty extends to the original purchaser and is not transferable.  No person, 
agent, distributor, dealer or company is authorized to change, modify, or amend the 
terms of this warranty in any manner whatsoever. 
 
All products returned must have an “RA” (Return Authorization) number regardless of 
warranty status.  Call SIMCO for an assigned RA number. 
 
Information in this document is subject to change without notice and does not represent 
a commitment on the part of SIMCO.  No part of this manual may be reproduced or 
transmitted in any form or by any means, electronic or mechanical, including 
photocopying and recording, for any purpose other than the purchaser’s personal use 
without written permission of SIMCO. 

 

 

 

 

2257 North Penn Road 

Hatfield, PA 19440 

Phone:  (215) 997-0590 

(800) 538-0750 

Fax:  (215) 997-3450 

 

http://www.simco-static.com

 

e-mail: [email protected] 

 

 

10 

Содержание 4002612

Страница 1: ...roblem It can be applied in inspection testing and assembly environments The Aerostat XC can also be used where static electricity causes problems such as attraction of dirt to product misalignment of...

Страница 2: ...el ion emitters which results in an intense alternating electric field at the tip of the emitters It is this intense electric field that introduces alternating polarity ions into the air flow The shap...

Страница 3: ...enter line of air stream Air Flow Characteristics 3 x 6 Area Coverage Heated Air Temperature Fan Speed Above Ambient where applicable Low 11 F 6 C Medium 9 5 C High 7 F 4 C Measured 6 in front of unit...

Страница 4: ...rom 1000 volts to 100 volts Note Discharge times for high speed are 10 longer for 230 V 50 Hz SECTION 4 Safety 4 1 Read all instructions before proceeding with installation or operation Failure to fol...

Страница 5: ...s an optional air filter kit part number 5050281 is available The air filter kit contains user installed brackets and an air filter that can be cleaned and reused The Aerostat XC should be placed appr...

Страница 6: ...neutralize each other Positive and negative ions are electrostatically attracted to each other When they contact the charge transfers and the ions recombine With high air velocity the ions travel furt...

Страница 7: ...s stubborn wash the filter in mild soap and water then rinse Blot the filter dry with paper towels and allow to dry Reinstall filter on air inlet by sliding it under brackets from rear of the unit IMP...

Страница 8: ...on Balance in Section 3 Specifications Do not try to determine ion balance by holding a static meter in the ionized air stream This will result in a meaningless reading 7 6 Calibration The Aerostat XC...

Страница 9: ...eater ionizer and brush 6 4670700 Brush 7 4401510 Ionizer Duct Standoff 2 required 8 4103940 Line Cord Assembly 120 V 8 4104035 Line Cord Assembly 230 V 9 4610699 Illuminated Rocker Switch 120 V 9 461...

Страница 10: ...where state laws override This warranty extends to the original purchaser and is not transferable No person agent distributor dealer or company is authorized to change modify or amend the terms of thi...

Отзывы: