background image

SECTION 3   Specifications

 

 
Unit Part Number: 

4002612 4002667 

 

 
Line Voltage: 

120 VAC, 60 Hz.  220-230 VAC, 50 Hz 

 

 
Current Draw: 

Max. 3.6 Amp* 

1.8 Amp* 

 

 

Min. 0.6 Amp 

0.3 Amp 

 

 

   *Heater on 

 
Air Volume Output: 

Fan Speed Flow 

 Low 

70 

CFM 

 Medium 

95 

CFM 

 High 

102 

CFM 

 
Air Velocity 

Fan Speed 

1 ft.  2 ft. 

3 ft. 

4 ft. 

 

Low 

600 300 180 150 

 

Medium  800 400 220 180 

 

High 

1000 

500 250 200 

 

Velocity in FPM measured at center line of air stream 

 
Air Flow Characteristics: 

3’ x 6’ Area Coverage 

 
Heated Air Temperature: 

Fan Speed Above 

Ambient 

(where applicable) 

Low 

11

°

F (6

°

C) 

 Medium 

9

°

 (5

°

C) 

 High 

7

°

F (4

°

C) 

 

Measured 6” in front of unit. 

 
Operating Temperature: 

32

°

F (0

°

C) -- 122

°

F (50

°

C) 

 
Ozone Production: 

0.005 ppm measured 6” in front of unit 
Test conducted in accordance with EPA EQOA-0577-
019 using Dasibi Ozone Monitor model 1003AH 

 
Audible Noise: 

Fan Speed 

 

Low 

 52 dB 

 

Medium  58 dB 

 

High 

  64 dB 

 

measured 2 ft. from unit. 

 
Enclosure: Steel 
 
Finish: 

White Acrylic Enamel 

 
Weight: 

17.5 lbs (7.9 kg)  

 
Size: 

15-3/8” W x 4-1/2” H x 8-1/8” D 

 

Содержание 4002612

Страница 1: ...roblem It can be applied in inspection testing and assembly environments The Aerostat XC can also be used where static electricity causes problems such as attraction of dirt to product misalignment of...

Страница 2: ...el ion emitters which results in an intense alternating electric field at the tip of the emitters It is this intense electric field that introduces alternating polarity ions into the air flow The shap...

Страница 3: ...enter line of air stream Air Flow Characteristics 3 x 6 Area Coverage Heated Air Temperature Fan Speed Above Ambient where applicable Low 11 F 6 C Medium 9 5 C High 7 F 4 C Measured 6 in front of unit...

Страница 4: ...rom 1000 volts to 100 volts Note Discharge times for high speed are 10 longer for 230 V 50 Hz SECTION 4 Safety 4 1 Read all instructions before proceeding with installation or operation Failure to fol...

Страница 5: ...s an optional air filter kit part number 5050281 is available The air filter kit contains user installed brackets and an air filter that can be cleaned and reused The Aerostat XC should be placed appr...

Страница 6: ...neutralize each other Positive and negative ions are electrostatically attracted to each other When they contact the charge transfers and the ions recombine With high air velocity the ions travel furt...

Страница 7: ...s stubborn wash the filter in mild soap and water then rinse Blot the filter dry with paper towels and allow to dry Reinstall filter on air inlet by sliding it under brackets from rear of the unit IMP...

Страница 8: ...on Balance in Section 3 Specifications Do not try to determine ion balance by holding a static meter in the ionized air stream This will result in a meaningless reading 7 6 Calibration The Aerostat XC...

Страница 9: ...eater ionizer and brush 6 4670700 Brush 7 4401510 Ionizer Duct Standoff 2 required 8 4103940 Line Cord Assembly 120 V 8 4104035 Line Cord Assembly 230 V 9 4610699 Illuminated Rocker Switch 120 V 9 461...

Страница 10: ...where state laws override This warranty extends to the original purchaser and is not transferable No person agent distributor dealer or company is authorized to change modify or amend the terms of thi...

Отзывы:

Похожие инструкции для 4002612