MAINTENANCE
Control adjustments
To adjust choke control:
Remove air cleaner. Pull choke control to fully out position. Carburetor choke should be
completely closed. If not, loosen case clamping screw then move casing, wire and engine
choke lever in the direction shown until choke is completely closed. Tighten casing clamp
screw. Replace air cleaner.
Choke Control Adjustment
To adjust throttle control
Remove air cleaner. Move throttle control to FAST position. Swivel should be against throttle
stop. If not, loosen casing clamp screw. Move casing and wire in direction shown by arrow until
swivel is against throttle stop. Tighten casing clamp screw.
To prevent accidental starting, remove spark plug leads
from spark plugs and disconnect battery at negative
terminal when servicing engine or pump.
Casing
clamp
screw
Throttle
Stop
Swivel
Exhaust manifold