Psion Teklogix Vehicle-Mount Computer 8255 Скачать руководство пользователя страница 98

Содержание Vehicle-Mount Computer 8255

Страница 1: ...ISO 9001 Certified Quality Management System 7035 8255 8260 Terminals User Manual September 8 2003 Part No 80439 I...

Страница 2: ...is not to be reproduced or copied in whole or in part except for the sole purpose of promoting the sale of Psion Teklogix manufac tured goods and services Furthermore this document is not to be used a...

Страница 3: ...uld also be provided Before returning any products to the factory call the Customer Services Group for a Return Authorization number Support Services Psion Teklogix provides a complete range of produc...

Страница 4: ......

Страница 5: ...bly And Basic Operation 2 1 Preparing Terminals For Operation 15 2 1 1 Client Side Emulation Software 15 2 2 Preparing The 7035 For Operation 15 2 2 1 Connecting The 7035 Whip Antenna 15 2 2 2 The Bat...

Страница 6: ...splay 33 2 9 1 Adjusting The Display Contrast 33 2 9 2 Panning The Display Contents 35 2 10 The Integrated Scanner Option 7035 Only 35 2 10 1 Warnings 35 2 10 2 Operation Of The Integrated Scanner 35...

Страница 7: ...9 3 4 3 Accessing Macro Keys 60 3 5 36 Key 7035 Keyboards 61 3 5 1 Accessing Alpha Characters 61 3 5 2 Accessing Function Keys 63 3 5 3 Accessing The Macro Keys 64 3 6 QWERTY 8255 8260 Keyboards 67 3...

Страница 8: ...0 Emulation Keys 94 5 5 Data Entry 94 5 5 1 TESS Edit Modes And Cursor Movement 95 5 5 2 CLR Key Behaviour In TESS 96 5 5 3 DEL Key Behaviour In TESS 97 5 6 Lock Messages 98 5 7 Control Commands 99 Ch...

Страница 9: ...Menu 118 7 5 System 120 7 5 1 Volume And Contrast 120 7 5 2 Key Click 121 7 5 3 One Shot Mode 121 7 5 4 Typematic Rpt 122 7 5 5 Caps Lock On 123 7 5 6 Panning 123 7 5 7 Backlight 125 7 5 8 Font Size...

Страница 10: ...d Parameter Values 193 7 16 Security 194 7 16 1 Sup Password 194 7 16 2 Allow Teklogix 194 7 16 3 Tekterm Exit Password 195 7 17 ANSI FK Remap 195 Chapter 8 Terminal Accessories 8 1 External Bar Code...

Страница 11: ...e 213 8 8 2 Installation 213 8 8 3 Disassembling The Cradle Before Mounting 213 8 8 4 Mounting The Cradle 215 8 8 5 Installing The Cables 215 8 8 6 Connecting A Cable 215 8 8 7 Connecting The Power So...

Страница 12: ...Pack 7035 Only 241 Appendices Appendix A Support Services And Worldwide Offices A 1 Support Services A 1 A 1 1 Canada and USA Technical Support and Repair Services A 1 A 1 2 International Support A 1...

Страница 13: ...18 D 4 TRX7410 10A WLAN 902 Spread Spec Radio Parameters D 19 D 4 1 Channel D 19 D 4 2 WLAN Timing D 21 D 4 3 Power Saving D 21 D 4 4 CIS Data D 22 Appendix E AirFortress Secure Client E 1 Introductio...

Страница 14: ......

Страница 15: ...e assembly reverse compilation or other translation of the software is prohibited and iii software is copyrighted and licensed not sold and that title to the software is not transferred and iv the own...

Страница 16: ...Adapter or Driver Software in violation of United States and other national laws 2 Each such license agreement shall also include the following state ments or their equivalents i Except as otherwise e...

Страница 17: ...Fortress Product infringes any U S patents or copyrights excluding third party software provided that Fortress is immediately notified in writing and Fortress has the right to control the defense of...

Страница 18: ...ORDS OR DATA OR 3 SPECIAL INCIDENTAL OR INDIRECT DAMAGES OR FOR ANY ECONOMIC CONSEQUENTIAL DAMAGES INCLUDING LOST PROFITS OR SAVINGS EVEN IF FORTRESS ITS SUPPLIERS ORYOUR RESELLER IS INFORMED OF THEIR...

Страница 19: ...The Software and associated documentation were developed at private expense and are delivered and licensed as commercial computer software as defined in DFARS 252 227 7013 DFAR 252 211 7015 or DFAR 25...

Страница 20: ......

Страница 21: ...nufacturer PSION TEKLOGIX INC 2100 Meadowvale Boulevard Mississauga Ontario Canada L5N 7J9 Manufacturer s Address PSION TEKLOGIX S A in the European La Duranne 135 Rue Rene Descartes BP 421000 Communi...

Страница 22: ...ISO 7637 1 1990 ISO 7637 2 1990 EN 60950 1992 A1 A2 A3 A4 A11 Manufacturer PSION TEKLOGIX INC 2100 Meadowvale Blvd Mississauga Ontario Canada L5N 7J9 Year of Manufacture 1999 Manufacturer s Address PS...

Страница 23: ...ISO 7637 1 1990 ISO 7637 2 1990 EN 60950 1992 A1 A2 A3 A4 A11 Manufacturer PSION TEKLOGIX INC 2100 Meadowvale Blvd Mississauga Ontario Canada L5N 7J9 Year of Manufacture 1999 Manufacturer s Address P...

Страница 24: ...Ports ISO 7637 1 1990 ISO 7637 2 1990 EN 60950 1992 A1 A2 A3 A4 A11 Manufacturer PSION TEKLOGIX INC 2100 Meadowvale Blvd Mississauga Ontario Canada L5N 7J9 Year of Manufacture 1999 Manufacturer s Addr...

Страница 25: ...ain licence from Industry Canada Use only Teklogix approved peripheral devices and cables RF EXPOSURE REQUIREMENTS For vehicle mount terminals only To satisfy FCC RF exposure require ments for mobile...

Страница 26: ...sed of or replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the instructions described in Maintaining The 7035 Battery on pa...

Страница 27: ...bout This Manual 3 1 2 Text Conventions 4 1 3 About The Terminals 5 1 3 1 Features 5 1 3 2 The 7035 Hand Held Terminal 7 1 3 3 7035 Integrated Scanner Patent Numbers 11 1 3 4 The 8255 Vehicle Mount Te...

Страница 28: ......

Страница 29: ...ith all other keyboard keys Chapter 4 Tekterm outlines how to work with application sessions within the Tekterm program Chapter 5 TESS Operations describes editing modes status messages and control co...

Страница 30: ...11b Direct Sequence PC card and the TRX7410 TRX7410A 902 SS PC card Appendix E AirFortress Secure Client explains how to install and set up Secure Client software on your terminal Appendix F Parameter...

Страница 31: ...4 GHz compliant PC card radios 1 2 and 11 Mbps TRX7431 TRX7441 TRX7370 Narrowband PC card based radios 403 512 MHz 4800 19200 bps TRX7410 TekLan 902 MHz direct sequence spread spectrum radios 7035 ter...

Страница 32: ...pecial set of LEDs that act as shift indicators blinking when a key is active and staying on when a key is locked on softkey labels are displayed at the bottom of all terminal screens indicating the f...

Страница 33: ...Teklogix 7035 8255 8260 Terminals User Manual 7 Chapter 1 Introduction The 7035 Hand Held Terminal 1 3 2 The 7035 Hand Held Terminal Figure 1 1 The 7035 Hand Held 36 Key And 44 Key Keyboards...

Страница 34: ...Chapter 1 Introduction The 7035 Hand Held Terminal 8 Teklogix 7035 8255 8260 Terminals User Manual Figure 1 2 7035 I With Optional Pistol Grip Handle...

Страница 35: ...ction The 7035 Hand Held Terminal Figure 1 3 7035 Peripheral Port Figure 1 4 Infrared IrDA Port Warning Using controls or adjustments or performing procedures other than those specified herein may res...

Страница 36: ...cause harmful interference and 2 this device must accept any interference received in cluding interference that may cause undesired operation CANADA XXX XXX XXX FCC ID XXXXXX XX This product contains...

Страница 37: ...250 791 5 250 792 5 262 627 5 280 163 5 280 164 5 280 498 5 304 786 5 304 788 5 321 246 5 367 151 5 373 148 5 378 882 5 377 361 5 396 053 5 396 055 5 399 846 5 408 081 5 410 139 5 410 140 5 412 198 5...

Страница 38: ...Vehicle Mount Terminal LCD Only 12 Teklogix 7035 8255 8260 Terminals User Manual 1 3 5 The 8260 Vehicle Mount Terminal LCD Only Figure 1 7 The 8260 Vehicle Mount Figure 1 8 8260 Ports Expansion Port...

Страница 39: ...e Mount Terminal 18 2 3 2 Using The Cradle And Cradle Mounting Plate 19 2 3 3 Mounting The 8260 Terminal 21 2 3 4 Connecting The 8255 8260 Antenna 22 2 3 5 Installing The Cables 22 2 3 6 Installing Th...

Страница 40: ...trast Adjustment Using The Contrast Parameter 34 2 9 2 Panning The Display Contents 35 2 10 The Integrated Scanner Option 7035 Only 35 2 10 1 Warnings 35 2 10 2 Operation Of The Integrated Scanner 35...

Страница 41: ...ttery pack and if an external antenna is required connecting the antenna to the 7035 Important All battery packs must be charged before use A description of battery chargers is provided in Chapter 8 T...

Страница 42: ...the unit is operating will result in a full reboot Even after the system backup has expired the date and time are maintained for 100 hours without a battery To remove the battery pack Turn the termina...

Страница 43: ...o black 4 40 Phillips head screws are provided with the hand strap for attachment Four threaded inserts are available on the back of the terminal The hand strap can be attached either to the upper and...

Страница 44: ...udes 1 Mounting the terminal 2 Connecting the antenna 3 Installing the power extension Note Make certain that the unit is mounted inside the roll cage 2 3 1 Mounting The 8255 Vehicle Mount Terminal Th...

Страница 45: ...n the cradle so that the display side of the terminal is on the same side as the quick release fasteners The keyboard side of the termi nal should be on the same side as the tabs Match the side screw...

Страница 46: ...holes Note The bolts used for all installations are SAE 1 4 20 Figure 2 4 The Cradle Mounting Plate PN 18197 Attaching The Cradle To The Cradle Mounting Plate Next the terminal and cradle must be att...

Страница 47: ...nd Basic Operation Mounting The 8260 Terminal 2 3 3 Mounting The 8260 Terminal Figure 2 5 8260 Mounting Options 18452 001 Horizontal vertical cradle 18451 Cradle support plate 18239 Keyboard cradle 19...

Страница 48: ...ble To attach it follow the guidelines below For narrow band and WAN radios turn the antenna in a clockwise direction For spread spectrum radios turn the antenna in a counter clockwise direction The a...

Страница 49: ...fuse assembly PN 19440 provided with PN 13985 To connect the fuse assembly push the male connector of the fuse assembly into the female connector at the positive red lead of the power cable Connect th...

Страница 50: ...terminals depends on the application software running on the host computer The terminals interaction with the application depends on both the terminal operating system and the terminal hardware This c...

Страница 51: ...inals have on off switches at the back of the unit Reach around to the back of the terminal toward your right and press the On Off switch I represents on and O represents off 2 5 Resetting Terminals N...

Страница 52: ...ootup Normally the Tekterm application is launched automatically when the terminal is rebooted To bypass Tekterm and launch the Display Menu As the terminal is rebooting press the ESC key If you re no...

Страница 53: ...assword To exit DOS and return to the Display Menu Type start at the DOS prompt Press ENTER and then press ESC immediately To exit DOS and return to the Emulations screen Type start at the DOS prompt...

Страница 54: ...e equipped with additional LEDs that indicate whether or not a mode key is locked on Mode keys include CTRL ALT SHIFT ORANGE and BLUE For example when the CTRL key is locked on the CTRL LED stays on s...

Страница 55: ...Subsequent alpha characters are presented in lowercase type On 56 key keyboards pressing SHIFT and typing an alpha key produces an uppercase letter ORANGE key not required SHIFT An uppercase SHIFT mes...

Страница 56: ...n orange on the terminal plastic becomes available orange A lowercase orange message indicates that the ORANGE key will be active only until the next key is pressed The alpha characters printed in ora...

Страница 57: ...e battery gauge blinks and the terminal beeps Depending on the type of radio installed and terminal use battery life is typically 9 hours Fast charge time for a Lithium Ion battery is generally 3 5 to...

Страница 58: ...ved to memory The beeper volume can be adjusted using the BLUE key in combination with function keys F3 and F4 To increase the beeper volume Press the BLUE key and then press the F3 key Repeat this ke...

Страница 59: ...e character visibility in low light conditions The 7035 and 8260 terminals have LCDs as a standard feature The 8260 is also available with an electroluminescent EL display The 8255 can be ordered with...

Страница 60: ...h these keys refer to the note on page 34 To lighten the display Press the BLUE key and then press F2 Repeat this key combination until the contrast suits your needs To work more efficiently with thes...

Страница 61: ...the following warnings 1 Do not look into the laser beam 2 CAUTION Using controls or adjustments or performing procedures other than those specified herein may result in hazardous radiation exposure...

Страница 62: ...appear until a successful decode is achieved or two seconds have elapsed For terminals using external scanners the warning message can be turned off by setting the Scan Indic parameter to N Refer to...

Страница 63: ...s after a successful scan 2 10 3 Scanning Techniques The Scanner Angle Hold the scanner at an angle Do not hold it perpendicular to the bar code Do not hold the scanner directly over the bar code In t...

Страница 64: ...below 20 C 4 F and the battery has less than a 30 charge remaining the terminal may not power up properly IN ORDER TO AVOID THESE ISSUES we recommend that the 7035 freezer terminal be stored and power...

Страница 65: ...for use in temperatures ranging from 30 C to 50 C 22 F to 122 F VFD and EL vehicle mounts Suitable for use in temperatures ranging from 30 C to 60 C 22 F to 140 F Designed for use in outdoor vehicle c...

Страница 66: ...rning 111 must be used On all versions of 8255 8260 vehicle mount terminals the contact lubricant PN 95146 Nyogel must be used Further the appropriate contact lubricant should be replaced at least mon...

Страница 67: ...d keyboard in an 8260 freezer terminal Conversely do not install a heated keyboard in a standard tempera ture 8260 terminal Warning Do not install the terminal in such a way that the power cable is be...

Страница 68: ...he 7035 since the adhesive may damage the plastic unless the adhesives are specifically formulated for plastics The 7035 scanner IrDA port and display window should be cleaned with a mild detergent an...

Страница 69: ...gix S A Parc Club Du Golf Bat 1 13856 Aix En Provence Cedex 3 France DO NOT DISPOSE OF IN FIRE mix with other battery types charge above specified rate connect improperly or short circuit the battery...

Страница 70: ......

Страница 71: ...55 8260 Key Lock Function 52 3 2 5 The Function Keys 54 3 2 6 The Macro Keys 55 3 3 44 Key 7035 Keyboards 57 3 3 1 Accessing Alpha Characters 57 3 3 2 Accessing Function Keys 57 3 3 3 Accessing Macro...

Страница 72: ...Keys 73 3 7 2 1 F1 To F10 Keyboard Function Key Access 73 3 7 2 2 F1 To F6 Keyboard Function Key Access 74 3 7 3 Accessing ABC Macro Keys 76 3 7 3 1 F1 To F10 Keyboard Macro Keys 76 3 7 3 2 F1 To F6 K...

Страница 73: ...able in three different alphabetic layouts QWERTY ABC and AZERTY In addition all these keyboard layouts are available in two keyboard types F1 to F6 and F1 to F10 The F1 To F6 keyboard type is equippe...

Страница 74: ...ctrl in the status area The status area also indicates whether or not the function of a mode key has been locked on Keys that have been locked on are displayed in the status area in uppercase letters...

Страница 75: ...in the direction of the arrow up down left and right The cursor is the flashing box or underline character that indicates where the next character you type will appear Manual Panning Keys Arrow Keys...

Страница 76: ...try locking the BLUE key on by pressing it twice You can then press any arrow key in any direction until the necessary information has been brought into view When you have finished panning the informa...

Страница 77: ...the ESC key has no effect Note On vehicle mount terminals without a dedicated ESC key the ORANGE key is used to access this function The TAB Key In a TESS application pressing the TAB key moves the c...

Страница 78: ...Function Keep in mind that vehicle mount terminals are available in two keyboard types F1 to F6 and F1 to F10 see 8255 And 8260 Vehicle Mount Terminal Keyboards on page 47 for a brief description Depe...

Страница 79: ...The F1 To F10 Keyboard On this keyboard type the CTRL ALT and SHIFT keys are printed in orange typeface on keys along the bottom row of the keyboard To lock the function of the any of these keys on Pr...

Страница 80: ...function of the CTRL key on Press CTRL CTRL You ll know the key is locked on when the corresponding LED stays on To unlock or turn off any of these keys Press the locked key a third time When the key...

Страница 81: ...55 8260 Vehicle Mount Keyboards QWERTY Page 70 ABC Page 76 AZERTY Page 80 Both 7035 hand held terminals and 8255 8260 vehicle mounts provide macro keys These keys can be programmed to insert a text st...

Страница 82: ......

Страница 83: ...Letters To display an uppercase letter Press the ORANGE key and then the SHIFT key before typing an alpha character Important Remember to unlock the ORANGE key when it is no longer required You need t...

Страница 84: ...example to access function key F13 Press the CTRL key followed by F1 To access function key F14 Press CTRL F2 and so on Accessing Shift Function Keys F25 To F36 Accessing F25 to F36 requires a key com...

Страница 85: ...tters To display an uppercase letter Press the SHIFT key and then type the alpha character 3 4 2 Accessing Function Keys The 56 key 7035 has 30 function keys the first four F1 to F4 are directly acces...

Страница 86: ...y F5 Press the BLUE key followed by alpha key A To access function key F6 Press the BLUE key followed by B and so on 3 4 3 Accessing Macro Keys 56 key 7035 terminals offer 10 macro keys M1 to M10 Thes...

Страница 87: ...ge 52 for a complete description of this function Because the alpha keys on a 36 key keyboard are laid out much like the letters on a telephone generally in groups of three letters per numeric key you...

Страница 88: ...ample suppose you want to type the letters a b and c These letters are all accessible from the numeric key 1 To type the letter a Press the ORANGE key and then press the numeric key 1 Press the Accept...

Страница 89: ...umeric keys 1 2 and 3 With the ORANGE key activated press 1 to type the letter a Press 2 to type d and press 3 to type the letter g To end alpha selection press the ORANGE key a second time 3 5 2 Acce...

Страница 90: ...key followed by F1 To access function key F22 Press SHIFT F2 and so on to F10 3 5 3 Accessing The Macro Keys 36 key 7035 terminals are equipped with 6 macro keys The first two M1 and M2 are directly a...

Страница 91: ...ing Instructions Accessing The Macro Keys Accessing Macro Keys M5 And M6 To access M5 Press the BLUE key followed by M1 To access M6 Press the BLUE key followed by M2 Important A step by step descript...

Страница 92: ......

Страница 93: ...type the letter q Press the Q key To type the letter w Press the W key and so on Creating Uppercase Letters To display an uppercase letter Press the SHIFT key before typing an alpha character 3 6 2 Ac...

Страница 94: ...keyboard To access F1 press F1 To access F2 press F2 and so on through to F10 Accessing ORANGE Function Keys F11 To F20 Each of these function keys is displayed in an orange box in the upper left port...

Страница 95: ...F1 To access F2 press F2 and so on to F6 Accessing ORANGE Function Keys F7 To F12 Function keys F7 to F12 are presented in orange print just above and to the left of the first six alpha keys on the ke...

Страница 96: ...nation with the ORANGE key and the appropriate alpha key For example To access F31 press SHIFT ORANGE and then press Q key To access F32 press SHIFT ORANGE W and so on 3 6 3 Accessing QWERTY Macro Key...

Страница 97: ...nd so on 3 6 3 2 F1 To F6 Keyboard Macro Key Access F1 To F6 vehicle mount keyboards have a total 12 macro keys M1 to M12 They are displayed in orange print above and to the left of alpha keys A throu...

Страница 98: ......

Страница 99: ...eyboards on page 47 for a brief description Depending on which keyboard type you are using accessing function keys differs slightly These differences are highlighted in this section Important Make cer...

Страница 100: ...isplayed in a blue box in the upper right corner of function keys F1 to 10 To access function keys F21 to F30 you ll need to press the BLUE key in combination with one of F1 through F10 For example To...

Страница 101: ...F13 To F18 To access function keys F13 to F18 you ll need to press the CTRL key in combination with one of F1 through F6 For example To access F13 press the CTRL key and then press F1 To access F14 p...

Страница 102: ...F1 To F10 keyboard accessing these keys differs slightly 3 7 3 1 F1 To F10 Keyboard Macro Keys The F1 To F10 keyboards offer 12 macro keys M1 to M12 They are displayed in blue print above and to the r...

Страница 103: ...rief description Depending on which keyboard type you are using accessing function keys differs slightly These differences are highlighted in this section Important Make certain that the appropriate k...

Страница 104: ...1 through F10 For example To access F21 press the BLUE key and then press F1 To access F22 press BLUE F2 and so on 3 8 2 2 F1 To F6 Keyboard Function Key Access F1 To F6 keyboards have a total of 36 f...

Страница 105: ...9 to F24 you ll need to press the CTRL key followed by the ORANGE key and then the appropriate alpha key For example To access F19 press CTRL followed by ORANGE and then press A To access F20 press CT...

Страница 106: ...1 to M12 They are displayed in blue print above and to the right of alpha keys A through P the first row of alpha keys and Q through S in the second row of alpha keys Press the BLUE key followed by th...

Страница 107: ...on Session Windows 84 4 4 Radio Statistics Screens 84 4 4 1 Viewing A Radio Statistics Screen 84 4 4 2 802 11 Radio Statistics Screen 85 4 4 3 TRX7370 NB 802 11 SS Radio Statistics Screen 86 4 4 4 802...

Страница 108: ......

Страница 109: ...TESS and or ANSI sessions This application accepts input from the terminal keyboard or from a serial device such as a scanner and provides output to a serial device such as a printer 4 2 Launching Te...

Страница 110: ...number 2 and so on Note The session the terminal displays on boot up is the last application to load If for example TESS is the first application and ANSI is the last then the last application in thi...

Страница 111: ...percentage value with 100 indicating excellent communication quality inpkts total number of received packets outpkts total number of sent packets inbyte total number of received bytes outbyte total n...

Страница 112: ...munication quality ch operating channel sc scan state indicates the current channel search state xm total number of transmitted messages xr total number of retransmissions xi total number of transmitt...

Страница 113: ...inals can detect the reboot when they reinitialize v1 the version of the 802 IQ v1 protocol CQ communication quality represented as a percentage value with 100 indicating the best possible communicati...

Страница 114: ...f radio coverage is adequate rt average round trip time This number represents the millisec onds taken to send a message and receive a response from the the base station va variance of the round trip...

Страница 115: ...remember to press the it a second time to deactivate it Telnet And 9010t Radio Statistics Telnet or 9010t statistics are displayed in the top portion of the 802 IQv2 screen These statistics are ident...

Страница 116: ...only one 802 IQv2 network controller The access point the terminal is associated with is not indicated rt Round trip time is the total time taken to communicate with the controller through the access...

Страница 117: ...ration 93 5 2 Working With Multiple Sessions 93 5 3 The Field Types 93 5 4 IBM 5250 Emulation Keys 94 5 5 Data Entry 94 5 5 1 TESS Edit Modes And Cursor Movement 95 5 5 2 CLR Key Behaviour In TESS 96...

Страница 118: ......

Страница 119: ...ting TESS session and adding a new session is described in the section titled Applications on page 146 A unique terminal number must be assigned in the Terminal parameter for each TESS session Refer t...

Страница 120: ...5 5 Data Entry The terminal accepts data until the operator presses a key that sends a transmission to the host computer The following actions cause the terminal to transmit Pressing a function key or...

Страница 121: ...o not perform any functions Pressing the UP or DOWN arrow key completes the entry field and then moves the cursor to the previous or next field Fcursor mode Press CTRL u to enter fcursor mode In this...

Страница 122: ...e same position in the field If the CLR key is pressed while the cursor is in the right most position in the field the terminal emits a keyboard error beep If the CLR key is used to clear data in a fi...

Страница 123: ...eted before the field is completed the field remains unmodified when the cursor leaves the field or when the screen is transmitted Replace mode In a left justified field the DEL key erases the charact...

Страница 124: ...mpty field result in a key board error beep In a right justified field the DEL function erases the character that is to the right of the cursor and then shifts the remaining data one position to the r...

Страница 125: ...if a print page from the host was not previously received at the terminal CTRL s Displays the terminal status continuously Below is a sample status line as it might appear at the bottom of your termin...

Страница 126: ......

Страница 127: ...2 Sending Data To The Host 103 6 3 Teklogix Keyboard And VT220 Equivalent Keys 104 6 4 Working With Sessions 105 6 4 1 Establishing A New Session 105 6 4 2 Listing Sessions And Moving To Other Sessio...

Страница 128: ......

Страница 129: ...t have a unique number assigned This parameter is described in the section titled ANSI Settings on page 147 When Tekterm is launched the first configured session will appear in the application To disp...

Страница 130: ...le 6 1 maps the equivalent VT220 keys Table 6 1 Teklogix Terminal Keyboard And VT220 Equivalent Keys Teklogix Key Equivalent VT220 Key UP arrow Up arrow DOWN arrow Down arrow RIGHT arrow Right arrow L...

Страница 131: ...tel in lowercase letters followed by the Host Name or IP address Press ENTER Log in as usual to begin working with the new session 6 4 2 Listing Sessions And Moving To Other Sessions To list the curre...

Страница 132: ...ion 2 Press ENTER 6 4 4 Printing A Screen To print each line of a screen with a CR LF between each line Press CTRL and type p The screen will be printed using the port configured as Print 6 4 5 Smart...

Страница 133: ...Adding Additional ASCII Characters 116 7 3 6 3 Entering Information In A String Entry Field 116 7 3 7 Saving Changes To Parameters 117 7 3 8 Resetting The Terminal 117 7 3 8 1 Resetting The 7035 117...

Страница 134: ...2 Other Options 133 7 6 3 Barcode 135 7 6 3 1 Code 39 135 7 6 3 2 Code 128 138 7 6 3 3 EAN 13 138 7 6 3 4 EAN 8 140 7 6 3 5 UPC A 141 7 6 3 6 UPC E 141 7 6 3 7 Codabar 142 7 6 3 8 Code 93 142 7 6 3 9...

Страница 135: ...Console 2 Parameter Settings 177 7 11 Global Macros 181 7 11 1 Displaying The Global Macros Menu 181 7 11 2 Displaying The Global Macros Table 182 7 11 3 Choosing An ASCII Character 182 7 11 4 Adding...

Страница 136: ......

Страница 137: ...The Parameter Manager provides access to the parameter menus The values assigned to the parameters can be viewed and adjusted to optimize communication at the site in which a terminal is operating No...

Страница 138: ...not requested when the terminal emulation application is launched A Supervisory or a Psion Teklogix level password is required to access the complete Parameters menu or the DOS prompt Type your superv...

Страница 139: ...es of parameters numeric Y N alpha and string entry In addition some menus have sub menus attached to them This section of the manual describes how to work with all types of parameters and sub menus 7...

Страница 140: ...The Previous Menu Press F2 the PREV function key or Press ESC 7 3 3 Numeric Parameters Numeric parameters are displayed in reverse video To increment or decrement a number Press the RIGHT or LEFT arro...

Страница 141: ...s the RIGHT or LEFT arrow keys 7 3 6 String Entry Parameters Important For detailed information about using string entry fields to program macro keys refer to Global Macros on page 181 A sequence or s...

Страница 142: ...lly pressing the RIGHT arrow key moves the cursor to the right but in a string entry field pressing the RIGHT arrow key cycles through the available ASCII characters instead If you ve already chosen a...

Страница 143: ...of the unit When the terminal is reset it reboots to the Tekterm application and parameter changes take effect 7 3 8 1 Resetting The 7035 To reset a 7035 Press and hold down the BLUE key and the ENTER...

Страница 144: ...g the default supervisory level password Refer to Allow Teklogix on page 194 for details about the Psion Teklogix support level password Important Only individuals with a supervisory level or Psion Te...

Страница 145: ...ustomization of a terminal To access sub menus attached to these parameters Use the UP and DOWN arrow keys to position the cursor on the appropriate menu item Press F1 the NEXT key to display the sub...

Страница 146: ...rast adjustments refer to Contrast Adjustment BLUE F1 And F2 on page 34 Adjustments made to the terminal beeper and the display using the Volume and Contrast parameters are saved to memory so that if...

Страница 147: ...s parameter to N disables the key click sound Tone The value entered in the Tone parameter determines the frequency of the key clicks and is measured in Hz The allowable range is 200 to 5000 The highe...

Страница 148: ...ressed once the modifier key remains on only until the next key is pressed If the modifier key is pressed twice it remains locked on or active until it is pressed a third time to turn it off Note When...

Страница 149: ...test the rate of character repeats 7 5 5 Caps Lock On This parameter operates like the CAPS LOCK key on your PC keyboard When Caps Lock On is set to Y all alpha characters are displayed in uppercase W...

Страница 150: ...This specifies that 2 characters must always be displayed to the left and right of the cursor and 3 lines must always be displayed below the cursor Bottom Margin The contents of the screen will not a...

Страница 151: ...he backlight turns on On Time The value entered in this parameter determines how long the backlight will stay on after a key is pressed a scan is completed or data is received On Time is measured in s...

Страница 152: ...es The allowable values are Disabled 10 secs 15 secs 20 secs 30 secs 45 secs 1 min 5 mins 10 mins 15 mins 20 mins 30 mins 45 mins 1 hour 2 hours and Always On Choosing Always On sets the backlight to...

Страница 153: ...ss the RIGHT arrow key to scroll through the options 7 5 9 Cursor Type Note This Cursor Type parameter is used by the DOS command line or by applications that do not provide cursor adjustment paramete...

Страница 154: ...map and press the RIGHT or LEFT arrow key until the colour value you want is displayed Press F4 to save your changes and reset the terminal See page 117 for terminal reset information 7 5 11 Watchdog...

Страница 155: ...wer Down parameter has expired When the time specified for the Power Off parameter has expired the terminal turns off A full reboot is required to return the terminal to full operating mode The allowa...

Страница 156: ...type of internal and or external scanner being used The 7035 hand held terminal can support both an internal and an external scanner at the same time Internal 7035 Only Note If you are using an Advan...

Страница 157: ...riate default 2 D settings scan the Set All Defaults bar code below Important When you select 2 D as the internal scanner the Console 2 port is disabled External The External external parameter must m...

Страница 158: ...ing The possible values for this character include b Compare with the beginning of decoded bar code e Compare with the end of decoded bar code x Compare with the entire decoded bar code a Compare anyw...

Страница 159: ...to Y may reduce the robustness of the decoding since the terminal must decode more potential bar codes For this reason it is not recommended that Short Code be enabled for general purpose bar codes wi...

Страница 160: ...is enabled set to Y the laser warning logo appears on the display whenever the scanner is activated For the Teklogix 7035 I integrated terminal this message is mandatory and appears even if this param...

Страница 161: ...peed and performance enable set to Y only those codes that are required by the application 7 6 3 1 Code 39 Full Ascii If this parameter is enabled set to Y the characters and are used as escape charac...

Страница 162: ...s of numeric digits followed by an alphabetic character This identifier defines the general category or specific use of the data contained in the rest of the bar code Note This parameter should not be...

Страница 163: ...er the ASCII decimal equivalent of this character Enter a value of 0 zero if no suffix is to be added Strip Leading This parameter determines the number of characters that will be removed from the beg...

Страница 164: ...Code 128 EAN UCC Set EAN UCC to Y to enable this type of bar code EAN UCC bar codes include group separators and start codes Include Sym Enabling setting to Y Include Sym causes the group separator s...

Страница 165: ...to be added Strip Leading This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added Notes 1 The appended characte...

Страница 166: ...o Disabled the scanner does not recognize an addendum If this parameter is set to Optional the scanner searches for an addendum and if one exists appends it to the main bar code When the parameter is...

Страница 167: ...decoded bar code data Size Chars See Size Chars beginning on page 139 Addendum Important Before Addendum can take effect the Short Code parameter in the Options menu see page 133 must be set to Y Refe...

Страница 168: ...the check digit is included with the decoded bar code data Size Chars See Size Chars beginning on page 139 Addendum Important Before Addendum can take effect the Short Code parameter in the Options me...

Страница 169: ...k If Include Chk is enabled set to Y the check digit is included with the decoded bar code data Size Chars See Size Chars beginning on page 136 7 6 3 10 I 2 of 5 Mod 10 Chk If this parameter is enable...

Страница 170: ...enabled set to Y it is assumed that the last digit is a check digit Include Chk If this parameter is enabled set to Y the check digit is included with the decoded bar code data Size Chars See Size Ch...

Страница 171: ...bar code data Size Chars See Size Chars beginning on page 136 7 6 3 13 IATA 2 of 5 Mod 10 Chk If this parameter is enabled set to Y the Mod 10 check digit is calculated ITF Chk If this parameter is en...

Страница 172: ...in this parameter The Name parameter must be completed with a name that is meaningful to the operator The Type field indicates the type of session you will be running In a Name field type a name that...

Страница 173: ...ent ANSI session If Auto Term is set to Y any value assigned to the Terminal parameter is ignored Note Auto Term is available when 802 IQv2 is assigned to the Host Conn parameter page 148 or when 802...

Страница 174: ...l number In addition each Teklogix terminal using the radio link must have a unique terminal number 7 7 1 1 Host Conn Important This option is not available when the terminal is operating with a narro...

Страница 175: ...er The default 9010t port number assigned is 9999 the maximum allowable value The default Telnet port number assigned is 23 with a maximum allowable value of 32767 ENTER Pmpt This string indicates tha...

Страница 176: ...o Y otherwise skip to step 7 7 Terminal looks for Login Failed in next transmission from host 8 Login successful or Login failed and return to step 1 Login Prompt When the terminal receives the string...

Страница 177: ...ameters menu Refer to ANSI FK Remap on page 195 for additional details 7 7 1 2 Screen Pages This parameter defines how many pages are accessible to application programs The ANSI control functions Next...

Страница 178: ...he cursor is at the right edge of the screen replace the previously displayed characters If Auto Wrap is enabled set to Y the cursor wraps to the next line when the current line is filled The display...

Страница 179: ...been programmed to perform specific actions in your application These keys are identified through softkey labels reverse video labels that are displayed at the bottom of the terminal screen These sof...

Страница 180: ...fields created with the Faint ANSI attribute that is Normal Bold Faint Blink Reverse or Underline Blink The value assigned to this parameter specifies the actual video attributes to be assigned to fi...

Страница 181: ...ed the terminal transmits only according to the Xmit Wait parameter If the ANSI block mode features are used this parameter should be set to 99 Note If the terminal is not in local edit mode the ENTER...

Страница 182: ...ation 7 Bit If this parameter is set to Y the terminal transmits 7 bit controls When set to N the terminal transmits 8 bit controls 7 Bit is set to Y by default 7 7 1 5 Keyboard Echo Mode The availabl...

Страница 183: ...ond to the code The selection made at this parameter does not affect how the DEL key operates at the terminal PrintScreen Key This parameter determines the hot key that will print the screen contents...

Страница 184: ...this parameter is disabled set to N a LF character received from the host causes the cursor to move down one line in the same column In addition the ENTER key transmits a CR When enabled set to Y an L...

Страница 185: ...r is added to the end of the data received 7 7 2 TESS Settings Each session you create has its own Settings parameters Additional TESS information is documented in Chapter 5 TESS Operations Auto Term...

Страница 186: ...session or another TESS session must each have a different terminal number In addition each Teklogix terminal using the radio link must have a unique terminal number 7 7 2 1 Host Conn Important This p...

Страница 187: ...ter defines the logical page width in characters used by the host computer application Emulator systems trim the host application screens to this width This page width cannot be smaller than the width...

Страница 188: ...Pages Saved This parameter determines the number of pages that can be stored and recalled at the terminal Storing frequently used page data at the terminal reduces the need for the host to retransmit...

Страница 189: ...rogrammed to perform specific actions in your application These keys are identified through softkey labels reverse video labels that are displayed at the bottom of the terminal screen These softkey la...

Страница 190: ...Enter the ASCII equivalent of this character The most commonly used characters are _ underline The ASCII equivalent for this character is 95 period The ASCII equivalent for this character is 46 Char...

Страница 191: ...h the user s input The terminal beeps if the entered data does not match Visible field matching means that the data to be matched is displayed in the entry field Enter the decimal value for the ASCII...

Страница 192: ...ession with the largest application number 1 4 receives the serial input The other s do not see any serial input SI Mode TESS supports communication to and from the terminal serial port using two meth...

Страница 193: ...Software Development Kits 2 You can configure the terminal to automatically transmit data received through the serial port without user intervention When SI Mode is set to Field automatic transmission...

Страница 194: ...SO Prefix This parameter determines the start of message character on serial output A value of 0 zero indicates no prefix Enter an ASCII numeric equivalent from 0 to 255 to represent the start charac...

Страница 195: ...next field Append Enter When enabled set to Y Append Enter causes an ENTER code to be appended to the bar code The ENTER code completes the entry of the bar code and moves the cursor to the next field...

Страница 196: ...the cursor moves according to field location If disabled set to N the cursor moves according to the numeric order of the fields Enter To F0 The ENTER key normally enters data into a field and moves t...

Страница 197: ...eter specifies the actual video attributes to be assigned to fields created with the Normal ANSI attribute that is Normal Bold Faint Blink Reverse or Underline Bold The value assigned to this paramete...

Страница 198: ...the actual video attributes to be assigned to fields created with the Underline ANSI attribute that is Normal Bold Faint Blink Reverse or Underline 7 7 2 8 Features Kbd Locked This parameter allows y...

Страница 199: ...ich the screen will be anchored Use increment When Use increment is enabled set to Y and the cursor is moved off the display the screen contents shift by the values specified in the X increment and Y...

Страница 200: ...n the codepage value and a font must be selected to display the characters menu The possible fonts are Small Large and Thai Note If the character you select does not exist in the host character set it...

Страница 201: ...ations For more information on the exact formats of the GPS sentences review the documentation included with your GPS receiver GGA When GGA is enabled set to Y a Global Positioning System Fix Data mes...

Страница 202: ...onsole 2 COM2 options allow you to enable disable and specify the accessories attached to these ports Possible values include Serial 1 Disable Enable Print Scanner Output and IrDA Printer Console 2 Di...

Страница 203: ...option is not available for the Serial 1 port 7 10 2 Serial 1 And Console 2 Parameter Settings Since the parameters for the Serial 1 and Console 2 ports are identical in most cases they are discussed...

Страница 204: ...ur terminal The 7035 can perform XON XOFF and or CTS RTS handshaking Keep in mind that CTS RTS hardware flow control generally results in faster data throughput Note Flow Control under Serial 1 contai...

Страница 205: ...ion fails Keep in mind that the value assigned to this parameter must be exceeded before data in the buffer is thrown away To disable this parameter and force the terminal to use Retry Tmo this parame...

Страница 206: ...lower than 1594120224 set Parity space all other parameters are identical to the newer firmware For details about the Scan See sub menu parameters refer to the Scan See Wireless Scan See Scanner User...

Страница 207: ...keyboard The methods used to create macros are described in this section 7 11 1 Displaying The Global Macros Menu Macros are programmed from within the Global Macros menu If the Tekterm application i...

Страница 208: ...o In macros the UP arrow DOWN arrow ENTER and DEL keys have the following functions The UP and DOWN arrow keys move the cursor between entry fields The ENTER key once moves the cursor to the first pos...

Страница 209: ...already chosen Type a numeric character for example type the number 7 Next press the DEL key The cursor is now positioned to the right of the previously selected ASCII character Press the RIGHT or LE...

Страница 210: ...s destination If the destination resides on a remote subnet the packet is routed to the appropriate gateway The accepted values for Net Mask range from 0 0 0 0 to 255 255 255 255 Note The terminal Net...

Страница 211: ...server The options in the sub menu DNS IP and DNS Domain allow you to specify the IP address and domain name of your DNS server The DNS domain is appended to any host name that does not include a suff...

Страница 212: ...the terminal attempts a registration renewal If for example this parameter is set to 20 the terminal will attempt to renew registration 20 seconds before Regstr Lifetime expires When setting this para...

Страница 213: ...cates the maximum number of registration retries on timeouts Depending on your system assigning a value from 3 the default value to 5 is recommended Reg RX Delay Mn The value assigned for Reg RX Delay...

Страница 214: ...hile normally the value assigned here should be fairly low the default value is 10 it is critical that you set the value high enough so that the terminal always has access to a Foreign Agent and never...

Страница 215: ...ntact Name Location and Batt Thresh Simple Network Management Protocol SNMP is the protocol used to monitor and manage devices attached to a TCP IP network providing they support SNMP SNMP uses Manage...

Страница 216: ...with this person Name The value assigned here is the name assigned by the network administrator for this managed node Normally this is the node s domain name Location This parameter is used to identi...

Страница 217: ...ro IP address will restrict the source of SNMP commands to be accepted only if they originate from the specified IP address A null IP address can be accessed from any source If the Access parameter ha...

Страница 218: ...klogix must be set to Y see page 194 The SNMP agent polls the channel quality on a periodic basis and compares it to the value assigned as the low channel quality threshold CQ Thresh If the channel qu...

Страница 219: ...e 1 And Scan Time 1 Scan tone 1 and Scan time 1 determine the frequency and duration of the first beep of a multiple beep Tone is measured in hertz and time in milliseconds Scan Tone 2 And Scan Time 2...

Страница 220: ...it in a secure place If you lose your password your terminal parameters can only be changed by Psion Teklogix personnel However Psion Teklogix can only help you if the Allow Teklogix parameter was se...

Страница 221: ...ault string associated with it When a function key is pressed the corresponding default string is sent to the host The ANSI FK Remap table allows these function key character sequences to be redefined...

Страница 222: ......

Страница 223: ...8 3 5 Charging The Battery 205 8 3 6 Battery Charge Fault Conditions 205 8 3 7 Charger Fault Conditions 206 8 3 8 Removing The Terminal From The In Unit Charger 206 8 3 9 7942 Charger Specifications 2...

Страница 224: ...213 8 8 4 Mounting The Cradle 215 8 8 5 Installing The Cables 215 8 8 6 Connecting A Cable 215 8 8 7 Connecting The Power Source 216 8 8 8 Attaching A Port Replicator 216 8 8 9 Picker Cradle Maintenan...

Страница 225: ...the manufacturer s instructions Use the wand as follows Hold the wand at less than 30 from the vertical If there is a switch on the wand turn it on before starting the scan Keep the tip in contact wit...

Страница 226: ...at least 72 hours without a battery 7035 Lithium Ion batteries typically operate for nine to fifteen hours1 after a charge These batteries do not require conditioning Each battery pack tracks its own...

Страница 227: ...generating heat or exploding adhere to precautions listed below Do not use the battery if the battery case is cracked or has signs of other physical damage The battery incorporates built in safety de...

Страница 228: ...extremely high temperatures e g a vehicle strong direct sunlight etc This may cause the battery to overheat or ignite and it may also reduce the performance and service life of the battery Do not use...

Страница 229: ...e Graceful Power Fail Operator is notified when battery capacity is low 8 3 The 7942 In Unit Charger Important The 7035 cannot be switched on while it is inserted in the 7942 in unit charger In fact i...

Страница 230: ...8 1 Charger LEDs 8 3 4 Inserting The 7035 With Battery In The Charger The 7942 Charger has a Power LED along with three additional LEDs Ready Charge and Fault Ensure that the green Power LED at the f...

Страница 231: ...Charge Fault Conditions The Fault LED remains on under one of the following circumstances The charger cannot read valid data from the battery pack The battery is not compatible with the 7942 charger...

Страница 232: ...y downward pressure to the front of the charger with one hand while pulling up on the terminal If necessary you may need to use a gentle side to side rocking motion to slide the terminal out of the ch...

Страница 233: ...fan is running 8 4 2 Inserting And Charging The Battery The 7967 Gang Charger has a Power On LED and each charge pocket has three LEDs Charge Fault and Ready Ensure that the green Power On LED at the...

Страница 234: ...cts and try charging the battery again In some cases foreign matter may block the battery receptacle interface Check the charger receptacle for debris and clear if required The hand held terminal has...

Страница 235: ...l front panel LEDs turn on momentarily The Power On LED then remains on indicating a power connection 8 5 2 Inserting And Charging The Battery The 7978 Gang Charger has a Power On LED and each charge...

Страница 236: ...e acceptable range and the fast charge is inhibited Remove the battery and permit it to cool to room tem perature before reinserting and restarting the charge 8 5 3 3 Yellow Charge LED Blinks Low Temp...

Страница 237: ...duct using battery Use of an attachment not recommended or sold by the battery charger manufacturer may result in fire electric shock or personal injury To reduce risk of damage to the electric plug a...

Страница 238: ...an overnight charge any of the batteries feel warmer than the charger housing The charger should be inspected by qualified service personnel Do not use the charger if any of the batteries or the charg...

Страница 239: ...obile e g a fork lift truck or fixed e g a work table For a typical installation 1 Choose a suitable mounting location 2 If necessary connect the pass through cable to an accessory 3 Connect the power...

Страница 240: ...Accessories Disassembling The Cradle Before Mounting 214 Teklogix 7035 8255 8260 Terminals User Manual The diagram below includes the disassembly of the pedestal mount Figure 8 2 Disassembling The Cr...

Страница 241: ...ot damage the vehicle or its wiring Protect cable runs from pinching overheating and physical damage Use grommets to protect cables that pass through metal Use plastic straps to prevent cables and con...

Страница 242: ...e side of the battery Warning Do not reverse the polarity or connect to a voltage outside the specified range Note also that the fuse should be UL approved 8 8 8 Attaching A Port Replicator A port rep...

Страница 243: ...orward so that the terminal can be inserted or removed and it tilts back to lock the terminal Figure 8 3 Unpowered Picker Cradle 7937A To insert the 7035 in the plastic cradle Using your thumb and fir...

Страница 244: ...tery pack PN 20605 003 is installed Battery is charging and capacity is less than 80 charged Red Cradle is locked Terminal is OFF and battery pack PN 20605 003 is installed Battery not charging becaus...

Страница 245: ...power Model 7937B 11 16 VDC 36 W max Model 7937C 10 55 VDC 36 W max Input connector AMP type CPC 206153 1 on flying lead Electrical interface 4 spring loaded heavy duty pogo type pins in base of unit...

Страница 246: ...which supplies the GPS unit with power from the Powered Sled supply and connects the data lines to the 7035 terminal The GPS unit should be mounted with a clear unobstructed view of the GPS satellites...

Страница 247: ...oes not harm the power supply inside the unit The diagram below illustrates recommended connection options Figure 8 5 Recommended Connections Note Teklogix provides another Transient Suppressor PN 198...

Страница 248: ...lash Resistant Carrying Case 30586 101 Rubber Carrying Case For 7035 with integrated scanner 21425 Rubber Carrying Case For 7035 without integrated scanner 31669 Mounts And Holding Devices 7035 Picker...

Страница 249: ...OM 1 233 9 4 2 Serial Port 2 COM 2 233 9 5 Memory Expansion Board 234 9 6 IrDA Port 7035 Only 234 9 7 Wireless Communication Options 234 9 8 GPS Unit 234 9 9 Bar Code Scanning 235 9 9 1 Internal Scann...

Страница 250: ......

Страница 251: ...Mbps Refer to Regulatory Information TRX7441 PC Card 802 11b DS SS beginning on page 225 for installation and usage information Refer to Program License Agreements on page xi for details about the end...

Страница 252: ...t or one of its peripheral devices If the equipment causes interference to radio or television reception try to correct the interference by using one or more of the following measures Turn the televis...

Страница 253: ...as identi ed in the documentation that comes with those products for additional information Interference Statement This equipment has been tested and found to comply with the limits for a Class B dig...

Страница 254: ...ncluding battery and radio With integrated scanner add 48 g 1 7 oz With pistol grip add 110 g 3 9 oz With hand strap add 17 g 0 6 oz Environmental Standard Temp Hand Helds Note For 7035 freezer termin...

Страница 255: ...Discharge temperature 20 C to 60 C 4 F to 140 F Battery storage temperature 20 C to 60 C 4 F to 140 F Battery life 9 hours at 23 C 73 4 F with TRX7370 radio 15 hours at 23 C 73 4 F with TRX7431 radio...

Страница 256: ...amel finish Size 287 mm 11 3 W x 64 mm 2 5 D x 229 mm 9 0 H Weight 3 4 kg 7 5 lbs 8260 Keyboard Physical Size And Weight Enclosure 16 gauge steel 1 5 mm 0 060 with baked enamel finish Size 287 mm 11 3...

Страница 257: ...p terminals operating temperatures and instructions refer to 8255 8260 Freezer Terminals on page 38 and 8255 8260 Low Temp Terminals on page 39 Note that 8255 LCD terminals are not available in a low...

Страница 258: ...Active Area 148 x 196 mm 5 8 x 7 7 Backlight Control Cold cathode fluorescent tube with programmable auto shutoff Font Sizes line x character 16x40 19x40 24x40 25x80 Resolution 640 W x 480 H Attribute...

Страница 259: ...ansfer Rates 2400 115 200 bps Compatibility User assigned Protocols Application dependent Limitations For the 7035 only COM1 is shared with the IrDA port only one peripheral can be active at one time...

Страница 260: ...ersion 1 1 physical and link layer Supported Transfer Rates All UART rates 2400 bps 115 200 bps Supported Modes UART Async Limitations Shared with serial port COM 1 Only one peripheral active at a tim...

Страница 261: ...r choose High Vis for the Scanner Type parameter Base Options High performance long range advanced long range and 2 D raster laser scanner Scan Triggering If an aiming dot is available on the installe...

Страница 262: ...tional Skew Tolerance 65 from normal 60 from normal Pitch Angle 55 from normal 65 from normal Roll Tolerance 20 from vertical 10 from vertical Specular Dead Zone 2 from normal 2 from normal Decode Dep...

Страница 263: ...matting Serial Param eters Beeper Tone Scan Angle Pattern controls Interfaces 8 pin ZIF connector Industry standard output 12 position ZIF connector Symbol Standard SSI interface with logic level seri...

Страница 264: ...als User Manual Figure 9 1 Pitch Skew And Specular Dead Zone Pitch Pitch Angle Scan Beam Scan Beam Scan Pattern Skew Angle Barcode Surface Barcode Surface Barcode Surface Scanner Side View Top View Si...

Страница 265: ...il 2 5 12 5 13 0 17 5 15 mil 2 5 18 5 8 5 33 5 20 0 50 0 20 mil 2 5 20 5 9 5 38 5 30 0 60 0 40 mil 3 0 29 5 9 5 79 5 30 0 98 0 55 mil 3 5 35 5 9 5 89 5 27 0 115 0 Bar Code Narrow Band High Performance...

Страница 266: ...APM Enabled full power state quickly when for example the operator presses a key or scans a bar code This state is not evident to the operator APM Suspend The terminal enters Suspend state from APM St...

Страница 267: ...ance Monitor Identifies the need for pack replacement Voltage 7 4 V nominal 6 0 V to 8 4 V maximum for battery pack PN 20605 003 Capacity 2200 mAh at 7 4 V nominal for battery pack PN 20605 003 Weight...

Страница 268: ......

Страница 269: ...troubleshoot problems over the phone and arranges for technicians or engineers to come to your site Canadian and U S customers may receive access to technical support services ranging from phone supp...

Страница 270: ......

Страница 271: ...018 Tel 1 859 371 6006 Fax 1 859 371 6422 Email salesusa psion com Psion Teklogix Finland Mets nneidonkuja 8 02130 Espoo Finland Tel 358 9 4307 8390 Fax 358 9 4307 8395 Email tekeuro psion com Psion T...

Страница 272: ...5 0220 Fax 34 9 3475 0230 Email teklogix apdo com Psion Teklogix Africa Postnet Suite 39 Private Bag x11 Halfwayhouse 1685 Ground Floor East Waterfall Edge Phase 2 Waterfall Park Bekker Road MIDRAND 1...

Страница 273: ...7 DIAG Input If grounded at power up causes terminal to enter diagnostic mode Menu allows flash ROM upgrade and other test modes Non Decoded Scanner 8 SCNR_ENABLE Output enable to initiate external s...

Страница 274: ...xpansion 2 23 EXP3 Expansion 3 24 EXP4 Expansion 4 Serial Port 1 COM1 25 RTS1 Request to send output RS 232D 26 CTS1 Clear to send input RS 232D 27 SERIAL1_TX Serial transmit data RS 232D 28 SERIAL1_R...

Страница 275: ...13 SERIAL2_RXD Serial data input RS 232D 14 SERIAL2_TXD Serial data output RS 232D Power 15 12V Unswitched 12VDC 500 mA fuse 16 12V Unswitched 12VDC 500 mA fuse Scanner Power 17 12V_SCAN_PWR 12 V swit...

Страница 276: ...on Ground 7 GND System ground 8 EXP_PORT 1 Reserved for future expansion Ground 9 GND System ground 10 EXP_PORT 2 Reserved for future expansion Ground 11 GND System ground 12 EXP_PORT 3 Reserved for f...

Страница 277: ...9 Reserved for future expansion 29 Keyboard GND For Teklogix use only 30 Keyboard 5 V For Teklogix use only 31 Keyboard CLK For Teklogix use only 32 Keyboard Data For Teklogix use only RS 232 Port 1...

Страница 278: ...ctive low for standard range 7035 Enables aim dot for 7035 LR long range 4 LASER_ENABLE Enables scanner laser output active low generates aim dot 5 SCAN_ENABLE Scanner enable output active low enables...

Страница 279: ...in DIN Shield CASE Enable Ack 5V Trigger Scanner Data Serial In Serial Out Scanner Power 5V Ground Shield Enable Ack Trigger Scanner Data Serial In Serial Out 5V Output Female Female TERMINAL SCANNER...

Страница 280: ...aptor Cable PN 30092 Ground 1 2 6 7 13 14 5 3 2 Female Female 28 Pin PCR DE9 Ground Shield BOOT_MON_EXT Scanner Serial In Scanner Serial Out Ground Transmit Receive 7030 8055 8060 TERMINAL PC SERIAL P...

Страница 281: ...0001 0101 21 NAK 15 0001 0110 22 SYN 16 0001 0111 23 ETB 17 0001 1000 24 CAN 18 0001 1001 25 EM 19 0001 1010 26 SUB 1A 0001 1011 27 ESC 1B 0001 1100 28 FS 1C 0001 1101 29 GS 1D 0001 1110 30 RS 1E 0001...

Страница 282: ...2 5C 0101 1101 93 5D 0101 1110 94 5E 0101 1111 95 _ 5F 0110 0000 96 60 0110 0001 97 a 61 0110 0010 98 b 62 BINARY DEC ASCII HEX 0110 0011 99 c 63 0110 0100 100 d 64 0110 0101 101 e 65 0110 0110 102 f...

Страница 283: ...A9 1010 1010 170 AA 1010 1011 171 AB 1010 1100 172 AC 1010 1101 173 AD 1010 1110 174 AE 1010 1111 175 AF 1011 0000 176 B0 BINARY DEC ASCII HEX 1011 0001 177 B1 1011 0010 178 B2 1011 0011 179 B3 1011...

Страница 284: ...226 E2 1110 0011 227 E3 1110 0100 228 E4 1110 0101 229 E5 1110 0110 230 E6 1110 0111 231 E7 1110 1000 232 E8 1110 1001 233 E9 1110 1010 234 EA 1110 1011 235 EB 1110 1100 236 EC 1110 1101 237 ED 1110 1...

Страница 285: ...tended Service Set Identifier is a string of characters to a maximum of 32 that the terminal uses to determine with which access points it can communi cate The terminal will only communicate with acce...

Страница 286: ...communicate at 11 Mbit if Data Rate is set to Auto Reservation Reservation specifies the medium reservation setting to be used The medium reservation specifies the number of octets in a message or fra...

Страница 287: ...an Ad Hoc network terminals pass data directly to other terminals an access point is not required In an Infrastructure network terminals must pass data through an access point terminals cannot communi...

Страница 288: ...Access Point with which the terminal will be communicating Depending on the type of Lucent WaveLAN card installed in your terminal Silver or Gold the allowable encryption value varies Allowable value...

Страница 289: ...are used for 802 1X authentication If Stored User ID is disabled you will be prompted to enter a user name and password when the terminal is powered up User Name And Password The Name and Password as...

Страница 290: ...er is used Refer to Radio Address in this section for details about manually assigned radio addresses Important Ensure that all terminals grouped in the system use the same addressing process that is...

Страница 291: ...cannot calculate an average round trip time without a number of transmissions a starting point or Initial Round Trip Time is required The terminal uses the time assigned to the Initial RTT parameter a...

Страница 292: ...cess points configured with the same ESSID If a value is not assigned for this parameter or if ANY is entered the terminal will communicate with any available access point Station The value entered in...

Страница 293: ...r of these packet types Pwr Mode The value assigned to this parameter determines the operating method the terminal uses to conserve power The default value CAM Constant Awake Mode keeps the Cisco radi...

Страница 294: ...communicate with Cisco access points that have encryption set to optional that is whether or not encryption is available the terminal will be able to communicate with a Cisco access point If Mixed Cel...

Страница 295: ...s of encryption used The Cisco Access point Encryption by Station parameter must be set to Open Authentication Accept Type parameter set to Open The terminal radio uses full encryption The CiscoAccess...

Страница 296: ...he encryption key from 1 to 4 that will be used to encrypt transmissions For example if you assign a value of 1 Key 1 is used to encrypt transmissions If you assign a value of 2 Key 2 is used to encry...

Страница 297: ...is reset by pressing and holding down the BLUE key and the ENTER ON key for a minimum of six seconds D 3 1 Cellular Auto Radio Addr If this parameter is set to Y the terminal requests an automatically...

Страница 298: ...ted must be an enabled channel Refer to Channel Enable on page D 15 on for details about enabling channels Power Up Chan If this parameter is enabled set to Y the terminal will start communicating on...

Страница 299: ...determine when commu nication quality with a base station is unacceptable When this threshold is exceeded the terminal starts channel searching for a new base station Setting this parameter to Slow me...

Страница 300: ...le Each channel list consists of up to 8 channels with all channels enabled before they are entered into the Manual Table If communication quality falls below 46 only the channels entered in the Manua...

Страница 301: ...the timing of the radio protocol This parameter specifies the amount of time in milliseconds the terminal should add to each response window in order to accommodate the receive transmit switching cha...

Страница 302: ...parameter determines how many transmit opportunities base station polls with available response windows must be consecutively skipped for the terminal to put the radio into power down mode for power...

Страница 303: ...l Refer to Channel Enable on page D 20 for details about enabling channels Power Up Chan If this parameter is enabled set to Y the terminal will start communicating on the channel specified in the Cha...

Страница 304: ...all other channels are enabled the terminal may roam through all 7 channels Note that the Channel Enable menu only displays channels that have been configured with frequencies Channel Auto These para...

Страница 305: ...uration of time the radio stays on after a message is sent twice this period if application data is sent PwrON time is in units of 1 2 seconds The range is 0 to 20 and increases the radio on time in i...

Страница 306: ...hannels have been checked and no suitable channel is found This parameter is in units of 1 2 seconds To disable this parameter set it to zero PwrON xmit This parameter determines the amount of time th...

Страница 307: ...FORTRESS SECURE CLIENT E 1 Introduction AirFortress Secure Client provides added security to your wireless system encrypting data sent and received by your terminal Keep in mind that this is an option...

Страница 308: ...word At the DOS prompt type a to change the default drive to A At the A drive Run the upload utility on the 7035 ymodem If you are using a serial cable Type y to start the ymodem program at 57600 baud...

Страница 309: ...keep it in a secure place Choose Change Password from the startup menu In the New Password field type your new password press ENTER In the Confirm Password field type your password again A message ind...

Страница 310: ...the startup menu E 3 3 Turning Encryption On And Off Keep in mind that turning encryption off allows unencrypted data to be sent to and received by your terminal leaving your network open to potential...

Страница 311: ...lowing diagnostic information can be viewed Physical device identifier assigned to the device Encryption algorithm and current operating status on or off Device ID for the AirFortress Gateway AF1100 w...

Страница 312: ......

Страница 313: ...om Margin X Increment Backlight Threshold On Time Intensity 0 Black 0 1 Blue 1 2 Green 2 Power Serial Number Power down CPU speed Power off 3 Cyan 3 4 Red 4 5 Magenta 5 6 Brown 6 7 Lt Gray 7 8 Dark Gr...

Страница 314: ...railing Prefix Char Suffix Char Strip Leading Strip Trailing same as Size Chars Type Include Sym Size Chars 1 2 2 1 1 EAN 13 Inc Country Include Chk Size Chars Addendum Addendum same as EAN 8 Inc Chk...

Страница 315: ...Chk Include Chk Terminal Auto Term Host Conn Screen Conn Type Group Settings Columns Rows Scroll Mode Pages Saved App Parameter Cursor Type Font Size Softkeys 1 cont d F1 F4 Invis NULL Char Set Err Fu...

Страница 316: ...Mixed AIAG Rjct if Alpha Beam Lockout Fields Field Order Features Kbd Locked Enter To F0 Enter On Arr Entry Mode Open Fky Only Video All Fld Video Ign Bcode fld Enh Edit Mode Valid Numerics Normal Bo...

Страница 317: ...Newline Echo mode DEL key PrtScr key Serial Async In Exclusive Start End Lower Upper View Manager Anchor View X origin Y origin Use Increment X increment Y increment Display Shift Custom Chars Font Ov...

Страница 318: ...vary depending on the device assigned at Serial 1 and Console 2 and on the radio installed in the terminal Network Local IP Net Mask Default Gateway Use DHCP Use DNS Ether Packet Sz Mobile IP 802 IQ v...

Страница 319: ...trap SNMP Enable Communities Batt Thresh CQ Thresh 1 Community Exit Password IP Access RowStatus 6 Sound Beep tone Beep time Error tone Error time Scan tone 1 Scan time 1 Scan tone 2 Scan time 2 Scan...

Страница 320: ...ts Sleep Duration Radio Address Initial RTT 802 IQ v1 Auto Radio Addr User Name Password CIS Data Card information screen Network Channel 802 1X Stored User ID WEP Encrypt Key 1 Key 4 TX Key 1 Radio T...

Страница 321: ...Limit Radio information screen Pwr Off Time Poll Timeout Late Tx Limit Switch speed Manual table CH1 enable CH20 enable CH1 list CH20 list TRX7370 Narrow Band Radio Radio Radio Address Channel Wlan Ti...

Страница 322: ......

Страница 323: ...IQv1 88 802 IQv2 88 addresses network See also Network addresses 184 address info 802 IQv1 88 802 IQv2 90 Adhoc and Infra networks D 3 D 10 advanced long range SE1200ALR scanner 130 236 AIAG AIAG Stri...

Страница 324: ...t and End Serial 159 transmission strings settings 155 Transmit parameters 155 antenna installing on 8255 or 8260 22 installing 7035 15 AP Controller 802 IQv2 displaying 90 AP Density TRX7431 D 2 AP m...

Страница 325: ...suffix character 137 139 symbologies Codabar 142 Code 11 143 Code 128 138 Code 39 135 136 Code 93 142 D 2 of 5 144 EAN 13 138 EAN 8 140 IATA 2 of 5 145 I 2 of 5 143 MSI Plessy 144 UPC A 141 UPC E 141...

Страница 326: ...ng for 8255 and 8260 22 CAM Constant Awake Mode D 9 capacity of battery 31 42 Caps Lock On 123 Card Information Structure CIS D 13 D 18 D 22 Card Information Structure CIS TRX7431 D 7 Cellular NB Radi...

Страница 327: ...lick 134 Click Time scanner double click 133 Client Side Emulation 15 CLR DEL Key description of 50 in Local Echo mode ANSI 157 TESS sessions CLR key behaviour in 96 Codabar 142 Code 11 143 Code 128 1...

Страница 328: ...ying continuously 99 CTRL t status display with terminal 99 CTRL u 95 CTRL up arrow 94 CTRL w status display in Lock B H mode 99 CTRL Key 50 cursor field advance tab 94 field backspace 94 field exit 9...

Страница 329: ...de 162 Use Increment 173 video attributes 153 154 171 X Increment 173 X origin 173 Y Increment 173 Y origin 173 display contrast adjusting 33 Display menu 111 Display Menu accessing and using 26 DNS u...

Страница 330: ...tures parameters for TESS Settings 172 field advance key function 94 field backspace key function 94 field exit key function 94 Field mode 95 Field Order 170 fields auto tab fields 94 bar code only fi...

Страница 331: ...mReceiver 175 GGA 175 GLL 175 RMC 175 Tx Period 176 VTG 176 GPS parameters 175 GPS Unit 220 234 Grat Arp Max Ct 187 Grat Arp RX Dly 187 grey scale adjusting 127 Group ANSI Auto Term 147 160 Group Name...

Страница 332: ...16 handstrap 17 pistol grip 17 8255 and 8260 vehicle mounts 18 integrated scanner option 35 Intensity 7035 backlighting 125 Internal internal scanner types 130 Introduction E 1 in unit charger 7942 20...

Страница 333: ...9 Key 1 to Key 4 TRX7431 D 4 Key 1 to Key 4 TRX7441 D 12 locking and unlocking 7035 52 macro keys ABC keyboard 76 AZERTY keyboard 80 description of 55 QWERTY keyboard 70 36 key keyboard 7035 64 44 key...

Страница 334: ...keys 58 56 key keyboard accessing macro keys 60 maintenance See terminal maintenance 42 Manual Table D 16 MapRF See SNMP Simple Network Man agement Protocol 189 match fields 94 Max Num Binds 188 memo...

Страница 335: ...ANSI 103 148 Terminal TESS 93 number system digit 141 142 numeric fields Rjct if Alpha 170 numeric parameters 114 numeric parameters minimum maximum limits to 114 O Off On buttons 24 offices list 3 A...

Страница 336: ...ator attaching 216 powered 10 55 VDC model 7937C 212 powered 11 16 VDC model 7937B 212 power source connecting 216 specifications 218 unpowered model 7937A 212 pinouts B 1 pistol grip installing on 70...

Страница 337: ...g SHIFT Key 49 Pwr Mode Pwr Saving D 9 PwrOFF time D 22 PwrOFF Xmit D 22 PwrON time D 21 Pwr Saving 802 11b DS D 9 Pwr Saving 802 11 DS D 2 Q QWERTY keyboard 8255 8260 67 alpha keys accessing 67 funct...

Страница 338: ...dio link aborts received ra TRX7370 86 802 11 SS 86 radio statistics screen 84 802 IQv1 87 802 IQv2 89 802 11 85 radio statistics screen resetting 90 Rate of key repeats 123 rb received beacons 802 IQ...

Страница 339: ...212 general xxi scanner 35 safety warning scanner 35 SAVE key F3 113 Save key F4 31 55 sc TRX7370 scan state 86 sc 802 11 SS scan state 86 Scan Indic 134 SCAN Key 51 scanner advanced long range ALR 1...

Страница 340: ...7 TESS Scanner parameters 169 Translate bar code 132 trouble shooting tips 36 Type of scanner 130 Verify 133 warning message 35 Scan Result 134 Scan See configuring port for 180 console port settings...

Страница 341: ...6 180 Serial 1 Port Settings Buffer 179 Data Bits 178 disabling 176 enabling 176 Flow Control 178 Input Tmo 179 IrDA Printer option 177 Output option 176 Parity 178 peripheral devices 176 Print option...

Страница 342: ...anner 236 SE1200ALR 236 SE1200HP 236 SE1200LR 236 SE2223 2 D 236 2 D scanner SE2223 2 D 236 specular dead zone 238 Speed 178 spread spectrum 902 radio parameters D 19 D 22 spread spectrum radio 902 D...

Страница 343: ...special instructions 42 terminal serial number 802 IQv1 See Serial NO 88 802 IQv2 See Serial NO 88 TESS Append Enter 169 Append F0 169 Applications menu 146 AutoRep Fn 168 AutoRep T O 169 Auto Term 15...

Страница 344: ...con bt 802 IQv1 88 802 IQv2 88 timeouts poll pt TRX7370 86 802 11 SS 86 Timing parameters D 17 D 18 Tone key click 121 transient suppressor 220 Translate bar code 132 transmit TX key TRX7431 D 4 TRX74...

Страница 345: ...visible fields match 165 V Match Chr 165 Volume 33 volume adjusting 120 VTG Track made good and ground speed 176 VT220 Function keys equivalent Teklogix keyboard Function keys 104 v1 802 IQv1 version...

Страница 346: ...oard alpha keys accessing 59 function keys accessing 59 macro keys accessing 60 uppercase letters creating 59 7 Bit 156 7000 LED Version parameter settings 180 7000M LCD Version parameter settings 180...

Страница 347: ...nting cradle attaching terminal to 18 20 QWERTY keyboard 67 8260 ABC keyboard 73 antenna attaching 22 approvals 232 AZERTY keyboard 77 cables installing 22 display EL 232 LCD 232 extension power cable...

Страница 348: ......

Отзывы: