GB
The pipes should be fitted in such a way that any pressure variation caused by temperature
changes do not to affect the pump.
If the piping is very long, it must be suitably supported in front of and behind the pump and
it is best to place a retention or anti-hydraulic ram valve in the drive.
The plastic pipes and connections should be screwed carefully.
If a hose is used in suction, it must be non-compressible (with a reinforcement spiral).
The suction pipe/hose must be as short as possible to assure optimum working conditions.
It is recommended to install close valves on either side to isolate the pump.
Note: The pump does not allow work with a closed discharge valve as it may cause an in-
crease in the temperature and steam formation which can damage the pump.
If there is any danger of the pump working against a closed discharge valve, a by-pass/purg-
ing valve must be connected in a discharge pipe to ensure minimum liquid flow through the
pump.
To minimise possible noise from the pump, it is recommendable to install an anti-vibrator in
the suction and drive inlets and between the base plate and the pump.
According to the IEC no. 364 publication, the pump must be installed at least 2 m from
the swimming pool edge.
Make sure that the electrical supply is turned off before removing the connection box
cover or before any moving or disassembling of the pump.
The electrical connections must be performed by an authorised electrician and according to
the local standards.
The pump must be connected to an external switch.
The voltage and the frequency are marked on the characteristics plate. Make sure that the
motor is suitable for the electrical supply in use.
The motor must be connected to the electrical supply as shown in the drawing, using an ap-
proved, watertight cable and in accordance with local standards.
4
Electrical connections
3.1 Ventilation
The pump motor is cooled by the fan on the rear. We will therefore preferably place the pump
in a WELL VENTILATED place (protected from possible freezing), preferably in a room.
a) If the pump is installed OUTDOORS, it must be protected from the rain and the elements
with a suitable cover.
b) If the pump is installed in an underground or semi buried plant housing, a SUFFICIENT AIR
ENTRY must be assured for the motor ventilation in order to not be damaged (the inside
temperature should not exceed 50ºC).
c) In order to assure efficient cooling , the minimum distance between fan cover and the wall
or another obstacle situated at the back side of the motor must be more than 2,5 times
than the fan diameter.
Manual Maxi.2_PSH 25/03/13 16:49 Página 11
Содержание MAXI.2 15 T
Страница 26: ...P MAXI 2 Manual Maxi 2_PSH 25 03 13 16 49 P gina 26...
Страница 29: ...RU IEC 364 2 4 3 1 50 Manual Maxi 2_PSH 25 03 13 16 49 P gina 29...
Страница 30: ...P MAXI 2 4 1 K 5 5 6 X X Manual Maxi 2_PSH 25 03 13 16 49 P gina 30...
Страница 31: ...RU 69 7 8 9 1 2 3 4 5 3 6 7 1 2 K 3 4 Manual Maxi 2_PSH 25 03 13 16 49 P gina 31...
Страница 32: ...Dimensiones Dimensions Dimensions Dimensionen MAXI 2 Manual Maxi 2_PSH 25 03 13 16 49 P gina 32...