SMOKE DETECTOR 

 

    We highly recommend the use of a smoke detector.  It must be installed at least 15 feet (4,57 
m) from the appliance in order to prevent a false alarm when refueling the fire. 

 

 

DOOR GLASS 

 

    To maintain a clean and safe installation, do not build your fire too close to the glass or allow 
the logs to lean on the glass. 
 
    Do not operate your furnace at too low a setting.  Keep the air inlet opened long enough during 
the fire start-up to prevent the fire from going out,  which would soot up the door glass. 
 
    An intense fire will help keeping the glass clean.  However, in the event that your glass gets too 
dirty, which should not occur, you will have to clean it using a wet cloth and an oven cleaner.  The 
glass can be cleaned 

ONLY

 when the unit has cooled down.  Do not use abrasive cleanser.  You 

can find special cleansers for  wood stove glasses  in any  wood stove or hardware store.  
 
 

WARNING:  Avoid knocking or scratching the glass which could be damaged.

 

 

 

GLASS SPECIFICATIONS 

 
    The glass is made of Neoceram type of glass, 3/16” – (5 mm) thick. 
 
    Do not operate your furnace with a broken glass, as this could seriously damage your 
appliance. 
 
    You can purchase a replacement glass from your PSG dealer. 

 

 

ASH DRAWER 

 
    Your appliance is equipped with an ash drawer to collect ashes produced by the combustion of 
wood.  This drawer must not be left opened during combustion as this will cause over firing and 
serious damage to the furnace*. 

The drawer must be cleaned regularly.  
 

 

  

ASH GRATE 

 
    In case of ash grate damage, contact your dealer to get a replacement.  The steel cover on the 
ash grate is meant to optimize the temperature inside the combustion chamber and should only 
be removed to empty the ashes. 

 

 

*It is mandatory that the door and the ash drawer be kept closed while the appliance is in use. 
Maintain all seals in good condition ; in case of deterioration, contact your dealer for replacement. 

Содержание MAX CADDY

Страница 1: ...NUAL THOROUGHLY BEFORE OPERATING THE FURNACE CONGRATULATIONS You have purchased one of the finest wood add on furnaces available on the market Your furnace will provide years of satisfaction and safe...

Страница 2: ...IPE CONNECTOR AND DAMPER 8 DAMPER 9 COMBUSTION AIR 9 ELECTRICAL CONNECTIONS 10 THERMOSTAT 10 FAN CONTROL 11 4 OPERATING INSTRUCTIONS 11 LIGHTING 12 PREHEATING 12 HEATING 12 EARLY SIGNS OF OVERFIRED FU...

Страница 3: ...rate of 0 8 G P H US to 1 2 G P H US or any gas or electric furnace with comparable heat output 1 CHIMNEY AND DRAFT This furnace must be connected to a chimney certified for wood burning heating appli...

Страница 4: ...N B To minimize the frequency of the chimney cleaning buy your firewood at least one year before using it Store in a dry place in order to obtain the minimum moisture rate and optimize the efficiency...

Страница 5: ...glasses in any wood stove or hardware store WARNING Avoid knocking or scratching the glass which could be damaged GLASS SPECIFICATIONS The glass is made of Neoceram type of glass 3 16 5 mm thick Do n...

Страница 6: ...sary to install an outside air inlet see details in 3 INSTALLATION COMBUSTION AIR The furnace must be positioned so that the connector is as short as possible Minimize the use of 90o elbows The owner...

Страница 7: ...ce in the hot air plenum The temperature rise is obtained by subtracting the cold air return temperature from that of the air exiting in the hot air plenum 3 Make the following verifications OIL CFM o...

Страница 8: ...applied on the unit SEE FIGURE BELOW STATIC PRESSURE CHECK POINT MIN 0 020 W C 24 REAR WALL 45 ELBOW AIR INLET CAN BE ON LEFT OR RIGHT SIDE 6 SIDE WALL 18 CEILING HOT AIR PLENUM 6 72 1 12 MIN The fur...

Страница 9: ...t s strictly forbidden to connect a solid fuel burning appliance to a chimney deserving a propane or natural gas appliance Regulation CAN CSA B365 1 Do not install a manual damper For a proper install...

Страница 10: ...dow for a few minutes while lighting Take note that a house constructed or renovated in order to be airtight is liable to lack fresh air which is necessary for a proper combustion and operation of hea...

Страница 11: ...connected in series appendix 1 option 2 and the fan limit control of the existing furnace is located in the plenum the divider must be installed at least 5 127 mm above the fan limit casing This divid...

Страница 12: ...g and to use the low speed for continuous air circulation It is possible that the blower and motor pulleys have to be replaced in order to obtain the desired air flow through the system The use of a m...

Страница 13: ...nce a smoke back draft through the air inlets PREHEATING 1 Once the kindling is well ignited or the coals revived put 2 or 3 fire logs in such a way that the flames can interlace between the logs and...

Страница 14: ...IL OR OTHER SUCH MATERIALS We recommend that you burn seasoned hard wood only There are two important factors to be considered when choosing a type of wood the moisture content and the wood density Ha...

Страница 15: ...ce door is closed as well as the damper if necessary lower the thermostat setting or release the chain of the damper and CLOSE the barometric damper manually If the fire gets uncontrollable due to an...

Страница 16: ...es move the upper plate of the combustion chamber forward see drawing below Using the scraper clean the three exchanger pipes The accumulated dirt in the side exchangers will fall into the combustion...

Страница 17: ...mantled and cleaned The smoke pipe should be inspected to detect any defect If no defect is noticed put the flue back in place otherwise it must be replaced Use only wood as a combustible Seasoned har...

Страница 18: ...NCTION BOX BLACK C Y INTERLOCK BROWN BLACK FAN MOTOR EXISTING UNIT W G L2 R WHITE WHITE BLACK RED T T HONEYWELL L6064 LOW BLACK LINE FAN LIMIT 250 F OFF 110 F BLUE RED LINE LOAD HIGH ON 150 F LIMIT WO...

Страница 19: ...1 2 750mm B 25 1 2 648mm C 47 1 4 1200mm D 28 1 2 724mm E 24 1 2 622mm F 44 1118mm G 22 1 8 562mm H 14 3 8 365mm FLUE 6 152mm WEIGHT 445Lb 202kg TECHNICAL DATA MODELE TEMP BTU HR STATIC PRESSURE VARIA...

Страница 20: ...warm air outlet 2 x 14 damper or 4 x 12 WARM AIR SYSTEM INSTALLATION HOUSE DIMENSIONS Example 28 x 40 bungalow 1 120 sq ft 28 x 40 x 8 8 960 cu ft x 1 8 Ch air hr 16 128 Btu Exposed walls 40 40 28 28...

Страница 21: ...BER 41 2 3 4 5 8 41 2 6 4 9 15 8 3 5 16 4 41 2 9 31 2 1 8 11 4 9 7 1 2 3 3 3 3 3 3 3 3 4 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 6 6 7 8 8 8 8 BRICK 4 5X9 SPECIAL BRICK 1 25 X 9 BRICK 4 5X9 SPECIA...

Страница 22: ...1 10 APPENDIX 1 INSTALLATION OF ADD ON CADDY CADDY ADD ON EXISTING FURNACE MINIMUM DUCT SIZE 320 SQUARE INCHES R MINIMUM RADIUS 6 INCHES R R OPTION 2 DIVIDER EXISTING FURNACE CADDY ADD ON R OPTION 1 R...

Страница 23: ...se Ash drawer opened or leaking air Furnace too small Move the thermostat Adjust the air intake damper Balance the ventilation system to increase the heat input in the room where the thermostat is loc...

Страница 24: ...rt All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and...