PSG MAX CADDY Скачать руководство пользователя страница 24

 

 
 
 
 

 

23

PSG LIMITED LIFETIME WARRANTY 

The  warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This 
warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from 
factory. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any 
warranty claim to your PSG dealer.   

This warranty applies to normal residential use only.  Damages caused by misuse, abuse, improper installation, 
lack of maintenance, over firing, negligence, accident during transportation, power failures, downdrafts, or 
venting problems are not covered by this warranty. 

This warranty does not cover any scratch, corrosion, warping, or discoloration caused by over firing, abrasives or 
chemical cleaners. Any defect or damage caused by the use of unauthorized parts or others than original parts void this 
warranty. An authorized qualified technician must perform the installation in accordance with the instructions supplied 
with this product and all local and national building codes. Any service call related to an improper installation is not 
covered by this warranty. 
The manufacturer may require that defective products be returned or that digital pictures be provided to support the 
claim. Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be 
defective, the manufacturer will repair or replace such defect. Transportation fees to ship the product back to the 
purchaser will be paid by the manufacturer. Repair work covered by the warranty, executed at the purchaser’s 
domicile by an authorized qualified technician requires the prior approval of  the manufacturer. Labour cost and repair 
work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale 
price of the replacement part. All parts and labour costs covered by this warranty are  limited according to the table 
below.   
The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of 
the defect. The manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by 
refunding the wholesale price of any warranted but defective parts. The manufacturer shall in no event be responsible 
for any special, indirect, consequential damages of any nature, which are in excess of the original purchase price of the 
product. A one-time replacement limit applies to all parts benefiting from a lifetime coverage. This warranty applies to 
products purchased after March 1

st

 , 2009. 

DESCRIPTION 

WARRANTY APPLICATION 

PARTS LABOUR 

Castings, combustion chamber (welds only), castings, and heat exchanger 
(welds only). 

Lifetime 

3 years 

Stainless steel firebox components, secondary air tubes*, surrounds and heat 
shields, ash drawer, and plating* (defective manufacture). 

5 years 

3 years 

Carbon steel firebox components, glass retainers, handle assembly, C-Cast 
baffle*, and vermiculite baffle*. 

3 years 

1 year 

Oil burner, electrical elements, blowers, heat sensors, switches, rheostat, 
relays, damper motor, fan limit control, PC board, wiring, and other controls. 

2 years 

1 year 

Ceramic glass (thermal breakage only*), paint (peeling), gaskets, insulation, 
and ceramic fibre blankets. 

1 year 

n/a 

Firebrick 

n/a 

n/a 

*Pictures required 

Shall your unit or a components be defective, contact immediately your 

PSG 

dealer. Prior to your call make sure you 

have the following information necessary to your warranty claim treatment: 

 

Your name, address and telephone number;  

 

Bill of sale and dealer’s name; 

 

Serial number and model name as indicated on the 
nameplate fixed to the back of your unit; 

 

Nature of the defect and any relevant information. 

Before shipping your unit or defective component to our plant, you must obtain from your PSG dealer an 
Authorization Number. Any merchandise shipped to our plant without authorization will be refused 
automatically and returned to sender. 

Содержание MAX CADDY

Страница 1: ...NUAL THOROUGHLY BEFORE OPERATING THE FURNACE CONGRATULATIONS You have purchased one of the finest wood add on furnaces available on the market Your furnace will provide years of satisfaction and safe...

Страница 2: ...IPE CONNECTOR AND DAMPER 8 DAMPER 9 COMBUSTION AIR 9 ELECTRICAL CONNECTIONS 10 THERMOSTAT 10 FAN CONTROL 11 4 OPERATING INSTRUCTIONS 11 LIGHTING 12 PREHEATING 12 HEATING 12 EARLY SIGNS OF OVERFIRED FU...

Страница 3: ...rate of 0 8 G P H US to 1 2 G P H US or any gas or electric furnace with comparable heat output 1 CHIMNEY AND DRAFT This furnace must be connected to a chimney certified for wood burning heating appli...

Страница 4: ...N B To minimize the frequency of the chimney cleaning buy your firewood at least one year before using it Store in a dry place in order to obtain the minimum moisture rate and optimize the efficiency...

Страница 5: ...glasses in any wood stove or hardware store WARNING Avoid knocking or scratching the glass which could be damaged GLASS SPECIFICATIONS The glass is made of Neoceram type of glass 3 16 5 mm thick Do n...

Страница 6: ...sary to install an outside air inlet see details in 3 INSTALLATION COMBUSTION AIR The furnace must be positioned so that the connector is as short as possible Minimize the use of 90o elbows The owner...

Страница 7: ...ce in the hot air plenum The temperature rise is obtained by subtracting the cold air return temperature from that of the air exiting in the hot air plenum 3 Make the following verifications OIL CFM o...

Страница 8: ...applied on the unit SEE FIGURE BELOW STATIC PRESSURE CHECK POINT MIN 0 020 W C 24 REAR WALL 45 ELBOW AIR INLET CAN BE ON LEFT OR RIGHT SIDE 6 SIDE WALL 18 CEILING HOT AIR PLENUM 6 72 1 12 MIN The fur...

Страница 9: ...t s strictly forbidden to connect a solid fuel burning appliance to a chimney deserving a propane or natural gas appliance Regulation CAN CSA B365 1 Do not install a manual damper For a proper install...

Страница 10: ...dow for a few minutes while lighting Take note that a house constructed or renovated in order to be airtight is liable to lack fresh air which is necessary for a proper combustion and operation of hea...

Страница 11: ...connected in series appendix 1 option 2 and the fan limit control of the existing furnace is located in the plenum the divider must be installed at least 5 127 mm above the fan limit casing This divid...

Страница 12: ...g and to use the low speed for continuous air circulation It is possible that the blower and motor pulleys have to be replaced in order to obtain the desired air flow through the system The use of a m...

Страница 13: ...nce a smoke back draft through the air inlets PREHEATING 1 Once the kindling is well ignited or the coals revived put 2 or 3 fire logs in such a way that the flames can interlace between the logs and...

Страница 14: ...IL OR OTHER SUCH MATERIALS We recommend that you burn seasoned hard wood only There are two important factors to be considered when choosing a type of wood the moisture content and the wood density Ha...

Страница 15: ...ce door is closed as well as the damper if necessary lower the thermostat setting or release the chain of the damper and CLOSE the barometric damper manually If the fire gets uncontrollable due to an...

Страница 16: ...es move the upper plate of the combustion chamber forward see drawing below Using the scraper clean the three exchanger pipes The accumulated dirt in the side exchangers will fall into the combustion...

Страница 17: ...mantled and cleaned The smoke pipe should be inspected to detect any defect If no defect is noticed put the flue back in place otherwise it must be replaced Use only wood as a combustible Seasoned har...

Страница 18: ...NCTION BOX BLACK C Y INTERLOCK BROWN BLACK FAN MOTOR EXISTING UNIT W G L2 R WHITE WHITE BLACK RED T T HONEYWELL L6064 LOW BLACK LINE FAN LIMIT 250 F OFF 110 F BLUE RED LINE LOAD HIGH ON 150 F LIMIT WO...

Страница 19: ...1 2 750mm B 25 1 2 648mm C 47 1 4 1200mm D 28 1 2 724mm E 24 1 2 622mm F 44 1118mm G 22 1 8 562mm H 14 3 8 365mm FLUE 6 152mm WEIGHT 445Lb 202kg TECHNICAL DATA MODELE TEMP BTU HR STATIC PRESSURE VARIA...

Страница 20: ...warm air outlet 2 x 14 damper or 4 x 12 WARM AIR SYSTEM INSTALLATION HOUSE DIMENSIONS Example 28 x 40 bungalow 1 120 sq ft 28 x 40 x 8 8 960 cu ft x 1 8 Ch air hr 16 128 Btu Exposed walls 40 40 28 28...

Страница 21: ...BER 41 2 3 4 5 8 41 2 6 4 9 15 8 3 5 16 4 41 2 9 31 2 1 8 11 4 9 7 1 2 3 3 3 3 3 3 3 3 4 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 6 6 7 8 8 8 8 BRICK 4 5X9 SPECIAL BRICK 1 25 X 9 BRICK 4 5X9 SPECIA...

Страница 22: ...1 10 APPENDIX 1 INSTALLATION OF ADD ON CADDY CADDY ADD ON EXISTING FURNACE MINIMUM DUCT SIZE 320 SQUARE INCHES R MINIMUM RADIUS 6 INCHES R R OPTION 2 DIVIDER EXISTING FURNACE CADDY ADD ON R OPTION 1 R...

Страница 23: ...se Ash drawer opened or leaking air Furnace too small Move the thermostat Adjust the air intake damper Balance the ventilation system to increase the heat input in the room where the thermostat is loc...

Страница 24: ...rt All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and...