NOTE:
It is recommended to install an outside air inlet with
a diameter of at least 4" in the room where the
heating appliance is installed (see drawing below).
It is preferable to choose a wall which is not
exposed to dominant winds, depending on the
conditions surrounding your house.
N.B. The owner of the add-on
is responsible for the room’s air quality in case of negative pressure or
temporary negative pressure.
If there is a fan in the wood storage room, make sure it does not create a depression in the room where the add-on is
installed.
For more informat
ion regarding the installation of fresh air intake adapter, refer to the option’s manual.
15.14. HOT AIR PLENUM
The hot air plenum coming out of the add-on is to have a minimum height of 24" (610 mm). These dimensions for all
hot air add-on are in accordance with the standards CSA B140.4.
NOTE:
TO ENSURE ADEQUATE STATIC PRESSURE, THE SYSTEM SHOULD BE BUILT IN A WAY THAT THE
VOLUME OF COLD AIR RETURN IS AT LEAST EQUAL OR SLIGHTLY HIGHER THAN THE VOLUME OF THE HOT
AIR DISTRIBUTION.
Insulated pipe
(full length)
Fresh air
intake
Exterior wall
Free air
entry
Содержание CADDY MAX CADDY WOOD ADD-ON PF01102
Страница 7: ...7 5 Label plate ...
Страница 8: ...8 ...
Страница 13: ...13 INSTALLATION AND OPERATION INSTRUCTIONS MAX CADDY ADD ON SERIAL INSTALLATION FOR CANADA ONLY PF01102 ...
Страница 16: ...16 Option 3 Option 4 ...
Страница 21: ...21 REQUIRES 2 RELAY SPNO SPNC WHITE ROGERS P N 90 380 NOT INCLUDED AND 24V AVAILABLE ON EXISTING FURNACE ...
Страница 22: ...22 14 ELECTRICAL DIAGRAM FOR SERIAL ADD ON VIA MOTOR REQUIRES 1 RELAY 51035 WITH 1 JUNCTION BOX NOT INCLUDED ...
Страница 45: ...45 21 EXPLODED VIEW AND PART LIST ...
Страница 46: ...46 ...
Страница 47: ...47 ...
Страница 48: ...48 ...
Страница 49: ...49 ...