Содержание 58WAV

Страница 1: ...o not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Do not use this furnace if any part has been under water Immedia...

Страница 2: ...nance it takes to keep it operating at peak efficiency Years went into the developlnent of your new furnace Take a little time now to assure its most efficient opera tion for years to come 0 MODEL 58WAV UPFLOW FURNACE 2 MODEL 58ZAV DOWNFLOW HORIZONTAL FURNACE UPFLOW FURNACE COMPONENTS Relief Box _ Rating Plate _ Gas Valve Control Knob or Electric Switch On Oft _ Gas Valve _ Gas Burner Flame Sensor...

Страница 3: ...g remodeling be sure the colnbnstion air is fresh and uncontaminated If these coin pounds are burned in ymir fltrnace the heat exchangers and metal vent system may deteriorate A flmmce installed in an attic or other insulated space must be kept tree and clear of insulating material Examine the furnace area when installing the furnace or adding more insulation Some materials may be combustible NOTE...

Страница 4: ...f you don t smell gas go to the next step If a suspected malfunction occurs with your gas control system such as the burners do not light when they should refer to the shmdown procedures on the furnace or in the next section to turn off your system then call your dealer as soon as possible Should overheating occur or the gas valves fail to shut off the gas supply turn off the manual gas valve See ...

Страница 5: ... few degrees and compensating for the difference with warmer clothing can lnake a big difference in your fuel consumption on extremely cold days The few degrees at the top of your therlnostat coin fort level are the most costly degrees to obtain When the room telnperature drops below the telnperature selected on the therlnostat the furnace will switch on auto matically When the room telnperature r...

Страница 6: ...be checked every 3 or 4 weeks and cleaned if necessary If installed with t actory specified disposable media filter check or replace filter before each heating and cooling sea son Replace disposable media filter at least once a year If your furnace filter needs replacing be sure to use the same size and type of filter that was originally supplied Use the Furnace Filter Table and match your furnace...

Страница 7: ...nove side filters Downflow Horizontal Furnaces Only Two filters are located in the return air plenum above the blower above line of sight resting in the V shaped channel on top of the furnace See Fig 27 1 Turn offelectrical supply to the filrnace See Fig 21 2 Remove 2 screws froln blower access door and relnove the door 3 Remove the left side filter by tipping the filter toward the center and rais...

Страница 8: ...t the colnbnstion area and veto system before each heating season An accumulation of dirt soot or rust can mean a loss of efficiency and improper performance Build ups on the main bnrners can cause t aulty firing This delayed ignition is characterized by an alarmingly loud sound If your furnace makes a loud noise when the main burners are ignited shut down the furnace and call your selwicing deale...

Страница 9: ...Does the lever point in the same direction that the pipe runs open Or is it at a right angle to the pipe closed NOTE Before proceeding with the next checks turn off the electrical power supply to the fimmce Relnove access doors Is the comrol knob or switch on the gas valve turned to the ON position If this or the preceding check shows an interrup tion in the gas supply lnake sure the gas has not b...

Страница 10: ...s for blower motor oiling inforlnation When required the lnomr lnUStbe oiled by a qualified selwice technician 5 Routine inspection and cleaning replacelnent of the air filter 6 Inspection of all supply and return air ducts for obstruc tions air leaks and insulation Any problelns found should be resolved at this time 7 Inspection of filrnace installation for proper support and any obvious deterior...

Страница 11: ...11 ...

Страница 12: ...one directory under the Heating Equipment or Air Conditioning Contractors Systems heading for dealer listing by brand name Have available the Model No Series Letter Serial No of your equipment to ensure correct replacement part Carrier Corporation 7310 West Morris St Indianapolis IN 46231 Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice ...