WIL-19230-E-01
Wilden
®
8
Step 4
Using the 3/16" Hex Wrench, re-install the
top two air valve bolts, securing the Edge
Device to the pump. Be sure to not tighten
the bolts beyond the maximum torque
specifications outlined in your pump’s
manual. For Pro-Flo SHIFT it’s
13.6 N•m (120 in-lb).
Step 5
Fore Tier 2 Only
– Remove the muffler
from the muffler plate.
Step 6
For Tier 2 Only
– Install the leak detection
unit into the muffler plate with the appropriate
adaptors for the size of your pump. Refer to
the parts list on page 14 for the adaptor
appropriate for your pump. Hand tighten until
the last full turn ends with the leak detection
cable facing up.
Step 7
For Tier 2 Only
– Install the muffler into the
leak detection unit with the appropriate
adaptor based on your pump size, tightening
by hand. Identify the appropriate adaptors for
your pump size in the parts listing on page
14.
Step 8
For Tier 2 Only
– Install the leak detection
cable into the front port of the J-Box.
Step 9
Remove the rubber seal from the Edge Device.
INSTALLATION