WIL-19230-E-01

 

Wilden

® 

 

 

 

The following outlined Precautions are for the 

Wilden SafeGuard equipment only. For specific 

Precautions on your pump, please refer to your 

pump model manual. 

 

WARNING: 

Always wear safety glasses when  

operating a pump to avoid eye injury. If diaphragm  

rupture occurs, material being pumped maybe forced  

out of the air exhaust.

 

 

CAUTION: 

Before attempting any maintenance or repair, 

disconnect the compressed air line to the pump and allow all 

air pressure to bleed from the pump. Disconnect all intake, 

discharge, and air lines. Drain the pump by turning it upside 

down and allowing any fluid to flow into a suitable container. 

Be aware of any hazardous effects of contact with your 

process fluid.

 

 

WARNING: 

For more details on Cautions and Warnings 

for the pump that the SafeGuard system is to be installed, 

or is installed on, please see the associated pump model 

manual. All pump manuals are available on 

www.wildenpump.com Download Library.

 

 

CAUTION: 

When removing the end cap using compressed 

air, the air valve end cap may come out with considerable 

force. Hand protection such as padded glove or rag should 

be used to capture the end cap.

 

 

CAUTION: 

The SafeGuard Gateway Node must be 

mounted within 150 feet of the installed SafeGuard Edge 

Devices to ensure proper operation. Impediments between 

the pump, Edge Device and Gateway Node can cause this 

range to vary. The SafeGuard Gateway Node can handle up 

to 10 SafeGuard Edge Devices. 

 

 

 

WARNING: 

Changes or modifications which are not expressly 

approved by Wilden could void the authority to operate the 

equipment.

 

 

NOTE: 

SafeGuard complies with Part 15 of the FCC rules. 

Operation is subject to the following two conditions: (1) this device 

may not cause harmful interference and (2) this device must 

accept any interference received, including interference that may 

cause undesired operation.

 

 

NOTE: 

The SafeGuard Gateway Node contains licensee-

exempt transmitter(s)/receiver(s) that comply with Innovation, 

Science and Economic Development Canada’s licensee-

exempt RSS(s). Operation is subject to the following two 

conditions: (1) this device may not cause interference and (2) 

this device must accept any interference, including that may 

cause undesired operation of the device.

 

 

NOTE: 

SafeGuard has been evaluated for RF Exposure 

per RSS-102 and is in compliance with the limits specified 

by Health Canada Safety Code 6. The system must be 

installed at a minimum separation distance from the 

antenna to a general bystander of 8 inches (20 cm) to 

maintain compliance with the General Population limits.

 

 

NOTE: 

SafeGuard is not an ATEX Certified product and 

using the equipment on an ATEX compliant pump, voids 

the ATEX Certification.  

 

 

 

 

 

 

 

 

 

 

 

 

 

PRECAUTIONS – READ FIRST!

 

  Section 1 

Содержание Wilden SafeGuard

Страница 1: ...EOM ENGINEERING OPERATION MAINTENANCE Wilden SafeGuard Remote Monitoring and Alert System WIL 19230 E 01 Where InnovationFlows ...

Страница 2: ...2 Contents Section 1 Precautions Read First 4 Section 2 How It Works 5 Section 3 Dimensional Drawings 6 Section 4 Installation 7 Section 5 Maintenance 11 Section 6 Troubleshooting 12 Section 7 Exploded View and Parts List 13 ...

Страница 3: ...e original purchaser that your Wilden SafeGuard Remote Monitoring and Alert System Edge Device and Gateway Node shall be free from defects in material and workmanship under normal use for a period of one 1 year from date of shipment Due to the varied ways that product s can be accessed and or configured during use battery life is excluded from warranty If you have an active contract and damage pro...

Страница 4: ... proper operation Impediments between the pump Edge Device and Gateway Node can cause this range to vary The SafeGuard Gateway Node can handle up to 10 SafeGuard Edge Devices WARNING Changes or modifications which are not expressly approved by Wilden could void the authority to operate the equipment NOTE SafeGuard complies with Part 15 of the FCC rules Operation is subject to the following two con...

Страница 5: ...r Edge Device mounted directly onto the pump which communicates to a sensor reader Gateway Node The Gateway Node which can connect up to 10 Edge Devices Pumps operates as an encryption router securely transmitting the data from all pumps to the Cloud The Tier 2 system option includes an additional real time leak detection sensor The Leak Detection Sensor indicates a leak when fluid fills the senso...

Страница 6: ... 0 101 6 mm 4 0 101 6 mm 4 0 B 315 mm 12 4 358 1 mm 14 1 515 6 mm 20 3 515 6 mm 20 3 DIMENSIONAL DRAWING Section 3 Note Dimensional Drawing of Tier 2 represented on a PS420 Metal Pump Model For full dimensions of your specific pump model refer to the pump manual Note Dimensional Drawing of Tier 1 represented on a PS420 Metal Pump Model For full dimensions of your specific pump model refer to the p...

Страница 7: ... shown However the pumpdisassembly procedurewillbethesame NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Using a 3 16 Hex Wrench remove the top two air valve bolts Step 2 Once the top two air bolts are removed remove the top air valve end cap by simply lifting up on the end cap Step 3 For Tier 1 Only Take the Edge Device and mounting end cap add grease to the O R...

Страница 8: ...muffler plate with the appropriate adaptors for the size of your pump Refer to the parts list on page 14 for the adaptor appropriate for your pump Hand tighten until the last full turn ends with the leak detection cable facing up Step 7 For Tier 2 Only Install the muffler into the leak detection unit with the appropriate adaptor based on your pump size tightening by hand Identify the appropriate a...

Страница 9: ... to remove the cap Step 11 Insert 2 AA batteries into the battery slots Be sure to leave the tray empty where it s marked Leave Empty A light will flash blue when powered Reinstall the Edge Device cap and rubber seal The Wilden SafeGuard Installation is Complete INSTALLATION ...

Страница 10: ...nstallation is complete 4 Plug in the power adapter set the antenna facing up vertically and your Gateway Node should now be installed Technical Specifications The following outlines the technical specifications of the Gateway Node Maximum Number of Paired Edge Devices 10 Range Up to 150 ft Power Source 9 24 VDC Powered by External DC Supply Communication o 4G LTE Cellular Cloud Connectivity o 900...

Страница 11: ...s Power Blinks every 5 seconds Single Blink Edge Device is Paired Double Blink Edge Device is Not Paired LED Light 2 Mirrors Indicators on Pump Dashboard Single Blink Warning Double Blink Fault Leak Detection In the event that a leak is detected via the Leak Detection Sensor the product could potentially contaminate the float switch and the float switch may need to be replaced To replace the Leak ...

Страница 12: ...ws on the ears of the leak detector and gently pulling down on the detection well 2 Remove any debris that may have accumulated and replace the well TESTING THE FLOAT SENSOR 1 To test the float sensor remove the detection well by removing the screws on the ears of the leak detector and gently pulling down on the detection well The float sensor will stay with the main part of the leak detector 2 Ge...

Страница 13: ...d Metal Pump PS220 represented in the exploded view for Tier 1 and Tier 2 1 Option Tier 1 and 2 1 1 2 to 3 EXPLODED VIEW 38 mm 1 1 2 Pro Flo SHIFT Series Bolted Metal Pump PS420 represented in the exploded view for Tier 1 and Tier 2 1 1 2 to 3 Options EXPLODED VIEW AND PARTS LIST Section 7 ...

Страница 14: ... 04 8296 99 B Leak Detector 1 N A 02 8016 01 N A 04 8016 01 Pump Side Adaptor Coupling Leak Detection 1 N A 04 7425 01 N A 04 7505 01 Pump Side Adaptor Bushing Reducer 1 N A N A N A 04 6959 08 Muffler Side Adaptor 1 N A 04 6950 01 N A 04 7426 01 Gateway Node not shown in exploded view 1 99 8254 99 Note Not all parts are available to order outside the system EXPLODED VIEW AND PARTS LIST ...

Страница 15: ...WIL 19230 E 01 Wilden Notes ...

Страница 16: ...d Terrace CA 92313 5651 USA P 1 909 422 1730 F 1 909 783 3440 psgdover com Where Innovation Flows PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document 04 2020 ...

Отзывы: