background image

 

WIL-11430-E-05  

27 

PS400 Bolted Plastic 

 

NOTES 

 
 
 

Содержание WILDEN Pro-Flo SHIFT PS400

Страница 1: ...WIL 11430 E 05 Where InnovationFlows EOM ENGINEERING OPERATION MAINTENANCE MANUAL PS400 Bolted Plastic Pump...

Страница 2: ...California LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are reg...

Страница 3: ...Rubber Fitted 8 PS400 Plastic EZ Install TPE Fitted 8 PS400 Plastic Full Stroke PTFE Fitted 9 Suction Lift Capability 10 SECTION 6 Suggested Installation Operation Maintenance and Troubleshooting 11 S...

Страница 4: ...s not exceeded CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION Do not exceed 82 C 180 F air inlet temperature for all models CAUTION The process fluid and cleaning fluids must be co...

Страница 5: ...EPDM BLUE DOT FS SANIFLEX HYTREL CREAM FW SANITARY WIL FLEX IPD SANTOPRENE TWO BLACK DOTS NE NEOPRENE GREEN DOT PU POLYURETHANE BROWN TF PTFE WHITE VT FKM SILVER OR WHITE DOT WF WIL FLEX SANTOPRENE TH...

Страница 6: ...seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within...

Страница 7: ...50 DIA 5 9 DIA W 18 DIA 0 7 DIA ANSI FLANGE U 98 DIA 3 9 DIA V 127 DIA 5 0 DIA W 16 DIA 0 6 DIA LW0195 REV B PS400 PVDF DIMENSIONS ITEM METRIC mm STANDARD inch A 471 18 5 B 83 3 2 C 358 14 1 D 596 23...

Страница 8: ...ill fall in the center of the pump s performance curve Caution Do not exceed 8 6 bar 125 psig air supply pressure PS400 PLASTIC EZ INSTALL TPE FITTED Ship Weight Polypropylene 28 kg 62 lb PVDF 32 kg 7...

Страница 9: ...stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 1 bar 30 psig head pressure Example To pump 223 lpm 59 gpm against a discharge head of 3 4 bar 50 psig requires 5 5 bar 80 psig...

Страница 10: ...level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumping fluid elevat...

Страница 11: ...then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other mufflers to reduce sound leve...

Страница 12: ...ed to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss whi...

Страница 13: ...be unable to shift Pump runs but little or no product flows 1 Check for pump cavitation Slow pump speed down to allow thick material to flow into liquid chambers 2 Verify that vacuum required to lift...

Страница 14: ...ny hazardous effects of contact with your process fluid NOTE Your specific pump model may vary from the configuration shown however pump disassembly procedure will be the same NOTE Replace worn parts...

Страница 15: ...valve seats from the liquid chambers and inspect for nicks gouges chemical attack or abrasive wear Replace worn parts with genuine Wilden parts for reliable performance Using an appropriate sized wre...

Страница 16: ...separate from the shaft which remains connected to the opposite side diaphragm assembly Figure 9b Repeat disassembly instructions for the opposite liquid chamber Inspect diaphragm assembly and shaft...

Страница 17: ...de down and allowing any fluid to flow into a suitable container Be aware of any hazardous effects of contact with your process fluid NOTE Replace worn parts with genuine Wilden parts for reliable per...

Страница 18: ...from assembly Seals are not sold separately Remove the air chamber bolts with an appropriately sized hex socket Remove the air chamber and inspect the air chamber gaskets 2 Replace if necessary Step 7...

Страница 19: ...the air chambers have been removed the square air valve nuts 6 may be removed or replaced if necessary Inspect the center block shaft and air control spool Glyd rings 4 for wear If replacement is nece...

Страница 20: ...finally the wetted path The applicable torque specifications are on this page The following tips will assist in the assembly process Lubricate the air valve bore center section shaft and pilot spool...

Страница 21: ...With the seal clamped in the pliers insert the seal into the busing bore and position the bottom of the seal into the correct groove When the bottom of the seal is seated in the groove release the cla...

Страница 22: ...WIL 11430 E 05 22 PS400 Bolted Plastic SECTION 8 PS400 PLASTIC LW0197 REV B ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS EXPLODED VIEW AND PARTS LIST...

Страница 23: ...ushing Reducer 1 1 2 MNPT to 1 FNPT 1 04 6959 17 24 Muffler 1 MNPT 1 15 3514 99 25 Muffler 1 4 MNPT 1 04 3240 07 Wetted Path Components 26 Chamber Liquid 2 04 5005 20 04 5005 21 27 Washer Plain 406 x...

Страница 24: ...rene 04 1010 51 04 1080 51 Buna N 04 1010 52 04 1080 52 08 1300 52 500 04 1371 52 Geolast 04 1022 15 EPDM 04 1010 54 04 1080 54 FKM 04 1010 53 04 1080 53 Non Food Grade Saniflex 04 1031 46 Saniflex 04...

Страница 25: ...WIL 11430 E 05 25 PS400 Bolted Plastic NOTES...

Страница 26: ...WIL 11430 E 05 26 PS400 Bolted Plastic NOTES...

Страница 27: ...WIL 11430 E 05 27 PS400 Bolted Plastic NOTES...

Страница 28: ...USA P 1 909 422 1730 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non co...

Отзывы: