PSC XANTRA VV ADVANCED Скачать руководство пользователя страница 16

SPECIFICATION OF PV CHARGE CONTROLLER 

 

14 

7.

 

Model Instruction 

YQ    PV - LP ***/*** 

 

Yo Power 

                                    PV System 

                                                  Low Power System 

                                                                Rated System Voltage 

                                                                            Rated Charging Current 

8.

 

Technical Specification 

Electrical Parameter 

Rated system voltage 

12V/24V/48V, auto detect 

Max. input voltage 

100V 

Rated charging current 

30A/40A/50A/60A 

No. of input 

1 group 

No-load loss 

<0.5W 

Equalize voltage 

14.4V/28.8V/57.6V 

Adjustable 

Equalize recovery voltage 

13.2V/26.4V/52.8V 

Equalize charging time 

120 Minutes 

Float voltage 

13.8V/27.6V/55.2V 

Under voltage disconnect 

10.5V/21V/42V 

Under voltage reconnect 

12.6V/25.2V/50.4V 

Over voltage disconnect 

16V/32V/64V 

Over voltage reconnect 

15V/30V/60V 

Environment Parameter 

Display 

3’’ LCD (White backlight) 

Display language 

English 

Indicator light 

Error indicator/Charging indicator 

Terminal type 

TC Series barrier terminal 

Humidity 

0~98%, non-condensing 

Содержание XANTRA VV ADVANCED

Страница 1: ...123655444 Users Thank you very much for selecting our Solar Charge Controller This manual contains important information and suggestion about installation operation and trouble shooting Please read th...

Страница 2: ...G INSTRUCTION 5 3 3MOUNTING 5 3 4WIRING THE CONTROLLER TO THE SYSTEM 5 4 OPERATION 6 4 1INSTRUCTION OF HMI INTERFACE 6 4 2THE INSTRUCTION OF THE LCD DISPLAY 7 4 3INSTRUCTION OF SUBMENU 8 4 4INSTRUCTIO...

Страница 3: ...tempt to repair it without authority from manufacturer 1 2 3 Please avoid direct sunlight if you install it outdoor 1 2 4 Install external fuses breakers as required 1 2 5 Install the controller in we...

Страница 4: ...s manual nor the conditions and methods of installation operation usage and maintenance of the system controller Improper installation of the system may result in damage to property and as a result to...

Страница 5: ...ase also ensure that the permissible model specific rated currents and voltages are not exceeded No liability is accepted when the device is used in a manner other than for the intended purpose Handle...

Страница 6: ...short circuit there will be explosion or fire so be careful about it Warning The PV arrays may produce a high voltage which will shock to people it s very dangerous so be careful about it when you ins...

Страница 7: ...DC output positive pole and DC output negative pole the diagram as following Solar Panel Battery Load S S B B L L1 3 3 Mounting 3 3 1 Choose mounting location Mount the controller near to battery and...

Страница 8: ...n cause severe shock or injury Be careful operation when installing solar wiring 3 4 3 Connect loads to the controller NOTE Right connect the positive and negative 3 4 4 Confirm the wiring Double chec...

Страница 9: ...the LCD will display the following main screen Menu 1 4 2 1 The first line from left to right which in turn is equipment ID ambient temperature and total days the equipment runs 4 2 2 The second line...

Страница 10: ...The last line from left to right which in turn is the real time and date 4 3 Instruction of submenu 4 3 1 In the main screen press menu key it will enter to the following interface Submenu 1 Monitori...

Страница 11: ...nge The factory password is 1234 4 4 1 Device Set In the submenu 1 interface when the cursor in the 2 Device Set position press confirm key to the following interface Users can set the Equipment ID Da...

Страница 12: ...if battery real voltage low than this value the controller will stop giving DC output UV_Rect Under voltage recovery when battery real voltage recovery to this value from under voltage the controller...

Страница 13: ...onfirm key to the following interface 4 4 6 Factory Reset In the submenu 1 interface when the cursor in the 8 Factory Reset position press the confirm key to the following interface If user chooses th...

Страница 14: ...ze charging point Constant current regulation is used to prevent heating and excessive battery gassing As to factory default setting the equalize charging stage will remain 120 minutes and then enter...

Страница 15: ...e naked wires to make sure insulation is not damaged for serious sunshine frictional wear dryness insects or rats etc Maintain or replace the wires if necessary Check if LCD display Pay attention to a...

Страница 16: ...No load loss 0 5W Equalize voltage 14 4V 28 8V 57 6V Adjustable Equalize recovery voltage 13 2V 26 4V 52 8V Equalize charging time 120 Minutes Float voltage 13 8V 27 6V 55 2V Under voltage disconnect...

Страница 17: ...mes than rated system voltage Check if the solar power is high than the Max solar power which controller demands OV Temp High temperature The heat sink s temperature is very high The controller will s...

Страница 18: ...troller doesn t charge when sun light on PV modules The PV modules short circle Check if the connections of PV modules is right and tightened Small charging current The sunshine is not good Battery is...

Отзывы: