SPECIFICATION OF PV CHARGE CONTROLLER
10
voltage recovery to this value from over charge,
the controller will recharge the battery.
➢
EQ_Chrg: Equalize charging, when battery real
voltage is increased to this value, the controller
will enter to equalize charging stage which
continue 120 minutes.
➢
FL_Chrg: Float charging, after 120 minutes of
Equalize charging, it will enter to float charging
stage.
➢
UV_Disc: Under voltage, if battery real voltage low
than this value, the controller will stop giving DC
output.
➢
UV_Rect: Under voltage recovery, when battery real
voltage recovery to this value from under voltage,
the controller will give DC output again.
➢
EQ_Time: Equalize charging time.
4.4.3
Load Set
In the submenu 1 interface, when the cursor in the “4.
Load Set” position, press confirm key to the following
interface
If the load state is OFF, there is no output. If the load
state is ON, there is output, users can set the output
time, this is suitable for streetlight model.
4.4.4
Password Set
In the submenu 1 interface, when the cursor in the “6.