Installation Manual
LazerData
®
11000 Scanner
Installation - 2.15
2.4.5
Outputs
The outputs are available only on 25-pin connector models. The following pins are
present on the 25-pin connector of the scanner:
25-Pin
Name
Function
8
NO READ+
No read output (+)
22
I/O REF-
I/O reference
11
RIGHT+
Right read output (+)
12
I/O REF-
I/O reference
40 VDC max
USER INTERFACE
Vext
NO READ+
8
22
I/O REF
11000
scanner 25-pin
and/or
11000
scanner 25-pin
RIGHT+
I/O REF
11
12
Figure 2.17 - Output connections
The NO READ output activates when the code signaled by the presence sensor is
not decoded.
The RIGHT output activates when the code is decoded correctly.
These outputs are both level- or pulse-programmable: a 50-ms pulse is generated in