PS Audio AV-3000 Скачать руководство пользователя страница 9

Installation and Operating Instructions  

 

AV-3000 and AV-5000 Power Centers 

 

 

 

 

4826 Sterling Drive, Boulder CO 80301 

 

        15-052-21-1 Rev B 

PH: 720.406.8946 [email protected] www.psaudio.com

 

 

©2009 PS Audio International Inc. All rights reserved. 

NOTE – 

Devices with large inrush currents, such as amplifiers, should only be placed on the parallel 

filtering outlets. Although other outlets will power such devices, large inrush currents may damage the 
relays which control the on and off settings of the outlet. 
 

Connect Phone 

To protect any device which connects to the telephone line connect the telephone cable from the wall 
outlet to the “TELEPHONE IN” jack on the PS AV Power Center. Then connect the telephone cable to the 
“TELEPHONE OUT” jack on the PS AV Power Center and to the device.  
 

Connect Satellite / Cable / Antenna

 

To protect satellite, cable, and/or antenna devices connect the coaxial cable from the wall to the coaxial 
“IN” jack on the PS AV Power Center. Then connect the coaxial cable to the vertically grouped “OUT” jack 
on the PS AV Power Center and to the device.  
 

Connect to the Network 

To protect any device which connects to the internet, connect the Ethernet cable from the wall outlet to 
the “DATA IN” jack on the PS AV Power Center. Then connect the Ethernet cable to the “DATA OUT” 
jack on the PS AV Power Center and to the device.  
 
To enable web based control connect an Ethernet cable from a live connection to the “ETHERNET” jack 
on the PS AV Power Center. 

 

 

 

2.4 

Self Test and Power Up 
When the PS AV Power Center is plugged into the wall or when it recovers from a power failure it will run 
a short self test. During the self test the device will illuminate the display window and display model and 
firmware information 
 
Upon completion of the self test the PS AV Power Center may be turned on by pressing the PS Audio 
blue logo button in the center of the front panel.  
 

2.5  

IP Status 
 
Once connected to the internet the PS AV Power Center’s proprietary internet connection service will 
auto detect and configure the required settings. An IP status indicator light is provided on the front panel 
to indicate the status as follows: 
 

R

R

e

e

d

d

 

 

– PS AV Power Center is not connected to the local network. Check to make sure the 

Ethernet cable is connected and an active network connection.  
 

B

B

l

l

u

u

e

e

 

 

(

(

A

A

V

V

-

-

5

5

0

0

0

0

0

0

)

)

 

 

o

o

r

r

 

 

G

G

r

r

e

e

e

e

n

n

 

 

(

(

A

A

V

V

-

-

3

3

0

0

0

0

0

0

)

)

 

 – The Power Center is connected to the local network 

and the Web. Configuration and control can now be performed through internal website. 

 
By default the PS AV Power Center is setup to rely on a DHCP enabled router or switch. If you are unable 
or do not wish to enable DHCP on the router or switch please refer to section titled 

2.6.2 Internal Website 

Configuration

 to configure the PS AV Power Center as a static device within the local network. 

 

 

 

 

Содержание AV-3000

Страница 1: ...s Reference AV 3000 and AV 5000 Power Centers 4826 Sterling Drive Boulder CO 80301 15 052 21 1 Rev B PH 720 406 8946 service psaudio com www psaudio com 2009 PS Audio International Inc All rights rese...

Страница 2: ...s two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not...

Страница 3: ...System Status 2 6 1 2 Control Panel Configuration 2 6 1 2 1 Unit Name 2 6 1 2 2 Front Panel Lock 2 6 1 2 3 Front Panel Dim 2 6 1 2 4 Zone Name 2 6 1 2 5 Switch Mode 2 6 1 2 6 UPS Priority 2 6 1 3 Con...

Страница 4: ...impeded current to your components for optimal performance Surge Protection Sophisticated surge and spike protection are contained in the AV Power Centers The protection circuitry is designed to prote...

Страница 5: ...go more than 10 minutes without an internet connection This feature ensures your Power Play is always available online 2 Installation and Operating Instructions 2 1 Unpacking and Inspection Upon rece...

Страница 6: ...and AV 5000 Power Cent 2 2 Overview Device Overview AV 5000 Front Panel 4826 Sterling Drive Boulder CO 80301 15 052 21 1 Rev B PH 720 406 8946 service psaudio com www psaudio com 2009 PS Audio Intern...

Страница 7: ...ons AV 3000 and AV 5000 Power Centers AV 3000 Front Panel 4826 Sterling Drive Boulder CO 80301 15 052 21 1 Rev B PH 720 406 8946 service psaudio com www psaudio com 2009 PS Audio International Inc All...

Страница 8: ...device match the power provided by the wall Plug the PS AV Power Center into a 2 pole 3 wire grounded receptacle wall outlet When used with the optional PowerPack UPS 1500 plug the PS AV Power Center...

Страница 9: ...wer Center and to the device To enable web based control connect an Ethernet cable from a live connection to the ETHERNET jack on the PS AV Power Center 2 4 Self Test and Power Up When the PS AV Power...

Страница 10: ...imply typing POWERCENTER into your browser The local IP address can be found by one of the following methods AV 5000 touch the IP indicator repeatedly until the display window shows IP AV 3000 press t...

Страница 11: ...the bar will be red Master Power On Master Power Off Identify and Control Outlets Outlet numbers and custom labels are displayed when the pointer hovers on top of the smaller boxes representing the ou...

Страница 12: ...y outlet naming Switch Mode and UPS Priority 2 6 1 2 1 Unit Name You may enter a description of your PS AV Power Center to help you remember the location within your home such as Theater Rack 2 6 1 2...

Страница 13: ...el is set to Dim of Off touching the capacitive display AV 5000 only or buttons will illuminate the display to Bright for 10 seconds and then return to the selected setting 2 6 1 2 4 Zone Name You may...

Страница 14: ...ate of the Power Button Delayed The outlet will follow the state of the Power Button after a 3 second delay Program Delay The outlet will follow the state of the Power Button after a programmed delay...

Страница 15: ...tery protection is provided but outlets turn off when the UPS reaches 25 battery remaining Use this setting to safely shut down devices such as projectors or any other device which requires some user...

Страница 16: ...a new IR command click on Add New Code 1 Enter a name for the command you wish to setup 2 Choose how you would like to trigger the event from the available options in the Trigger Event dropdown menu...

Страница 17: ...setup to rely on a DHCP enabled router or switch If you do not have DHCP enabled on your network or wish to set up your PowerPlay as a static address on the local network you may choose to disable DHC...

Страница 18: ...es while in front of the unit 2 6 2 1 AV 5000 From the front panel of the AV 5000 you may change the names of each outlet and the switch mode for the outlet 2 6 2 1 1 PS AV Power Center Master Power Y...

Страница 19: ...buttons or touch the display panel The display will remain illuminated for 10 seconds 2 6 2 1 5 Switch Mode 1 Select the outlet you wish to modify by touching the corresponding outlet on the front pa...

Страница 20: ...ll see the switch mode begin to flash Press SELECT again you will see the Outlet Label begin to flash We are now ready to modify the Outlet Label 3 Pressing EDIT UP will cycle through the available sw...

Страница 21: ...of the front panel The Master Power setting will only affect the outlets you have set to Switched Delay and or Programmed All other outlets will remain on The IP Indicator will remain illuminated whe...

Страница 22: ...used or misused damaged by accident or neglect or in being transported or the defect is due to the product being repaired or tampered with by anyone other than PS Audio or an authorized PS Audio repai...

Страница 23: ...nsent from PS Audio This warranty does not cover damage due to improper operation or maintenance connection to improper voltage supply or attempted repair by anyone other than a facility authorized by...

Страница 24: ...the responsibility for warranty of products sold by that retailer or distributor Warranty service should normally be obtained from the importing retailer or distributor from whom you purchased your pr...

Страница 25: ...To contact the PS Audio Service Department TELEPHONE 720 406 8946 HOURS Monday Friday 9 00 am to 5 00 pm MST FAX 720 406 8967 E MAIL service psaudio com WEBSITE http www psaudio co If you are in the...

Страница 26: ...y for loss or damage to the product during shipment to the dealer or distributor s Service Department and ensure all freight shipping charges are prepaid If You have Problems If you feel your country...

Страница 27: ...pation 7344 Joules EMI RFI Filtrations High Current Zones 60db 100kHz 2 MHz All Others 80db 100kHz 2 MHz DC Trigger Input Voltage Input 5 15V DC Jacks 3 5mm Mono Mini plug Center Positive Current Requ...

Страница 28: ...AV 3000 and AV 5000 Power Centers 4826 Sterling Drive Boulder CO 80301 15 052 21 1 Rev B PH 720 406 8946 service psaudio com www psaudio com 2009 PS Audio International Inc All rights reserved...

Отзывы: