![PS Audio AV-3000 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/ps-audio/av-3000/av-3000_owners-reference-manual_1622159019.webp)
Installation and Operating Instructions
AV-3000 and AV-5000 Power Centers
4826 Sterling Drive, Boulder CO 80301
15-052-21-1 Rev B
PH: 720.406.8946 [email protected] www.psaudio.com
©2009 PS Audio International Inc. All rights reserved.
1. Select the outlet you wish to modify by touching the corresponding outlet on
the front panel. Once selected the outlet will begin to flash.
2. Touch the outlet again while the indicator is flashing to toggle between power
on and power off.
Note: There is no delay or IR settings associated with direct panel control.
Changes made to the power settings are immediate.
3. If no changes are made the indicator will stop flashing in 10 seconds.
2.6.2.1.4 Dimming the Display
The display may be dimmed or defeated by pressing the
SELECT
button while
no outlets are flashing. The display will cycle through on, dim and off.
Note: When the display is defeated the entire display and all lights are off. To
temporarily illuminate the unit press either of the
EDIT
buttons or touch the
display panel. The display will remain illuminated for 10 seconds.
2.6.2.1.5
Switch
Mode
1. Select the outlet you wish to modify by touching the corresponding outlet on
the front panel. Once selected the outlet will begin to flash.
2. Press
SELECT
and in the LCD window you will see the Switch Mode begin
to flash. We are now ready to modify the switch mode.
3. Pressing
EDIT UP
will cycle through the available Switch Modes as follows
(
EDIT DOWN
cycles though the same list in reverse order):
SW = Switched
– The outlet will follow the state of the Power Button
DLY = Delay
– The outlet will follow the state of the Power Button after a
3 second delay
PGM = Program Delay
– The outlet will follow the state of the Power
Button after a programmed delay. Note: The Program Delay can only be
altered through the web based interfaces, the default is 3 seconds.
RBT = Reboot
– The outlet is ALWAYS ON, but may be rebooted
through the web interface
ARB = Auto Reboot
– The outlet is ALWAYS ON, may be rebooted
from the web interface, and automatically reboots when no web
connection is detected for 10 minutes.
4. To confirm and save your selection press
SELECT
while the desired setting it
flashing.