Features

ProR Series Zoning Panels

Model ProR321J Shown

Multi-color LEDs indicate zone
thermostat call status.

Green for cooling call.

Green for cooling call.

Blinks yellow during timing delays, purge 
or supply air temperature limit.

Red for heating call.

Red for heating call.

Blinks red if sensor failure detected.

Blinks green when operating normally.

Green when damper open.
Off when damper is closed.

Yellow for fan call.

Yellow for fan call.

Blinks for staged call or Em Heat.

Blinks for staged call or Em Heat.

 LED is green when fresh air 
damper is open.

LEDs indicate zone
damper position.

Multi-color LEDs indicate
equipment call status.

Jumper plugs for selecting
type of equipment.

Multi-color LEDs indicate
zoning panel status.

Terminals for gas/electric
systems or heat pumps.
2-heat, 1-cool or 
1-heat, 2-cool.

Connectors for plug and 
play dampers. 

Connector for plug and 
play damper for fresh air 
intake and exhaust per 
ASHRAE 62.2 and Title24 .

24VAC power for panel
and dampers.

Electronic circuit breaker/fuse.

Connectors for PDMi3 carried by installer for setting 
advanced options, cloning and monitoring installation.
Provided free to qualified contractors.

Terminals for optional duct pressure 
sensor (PS2).

Terminal for optional outdoor temperature 
sensor (TS3) for dual fuel HPs.

Terminals for leaving air temperature sensor
(TS2) to prevent over-heating the plenum or
freezing the indoor coil.

Color coded terminals for 
heat/cool or heat pump 
thermostat. Thermostat
type automatically selected.

Color coded terminals for 
heat/cool thermostat.

Use 24VAC powered or 
battery powered thermostats.

2

Содержание ProR212J

Страница 1: ...nfigure a zone All panels operate with gas electric systems conventional heat pumps and dual fuel heat pumps Selected using the jumper plugs on the panel See table below See table below See table belo...

Страница 2: ...ir damper is open LEDs indicate zone damper position Multi color LEDs indicate equipment call status Jumper plugs for selecting type of equipment Multi color LEDs indicate zoning panel status Terminal...

Страница 3: ...n below 1 3 HVAC PANEL ZONE DAMPERS 1 1 2 2 3 FAD 3 THERMOSTATS Quick View ProR321J Zoning Panel ProZone Two 8 screws Two 8 screws Panel 3 Zone Maximum VA 40VA Transformer 60VA Transformer 75VA Transf...

Страница 4: ...VAC Thermostat R C Y or Y1 G Zoning Panel R C 24VAC 24VAC Common Cooling Stage1 Indoor Fan Y G Terminal Function W1 OB Stage1 Heating W1 OB Inside Day Th MODE MENU FAN SYSTEM Schedule Auto Heat Heat S...

Страница 5: ...AC EQUIPMENT W2 E Y2 R R O O B W1 B W Y Y1 Wiring HVAC Equipment Gas Electric System Two Stage Heat Gas Electric System Two Stage Cool Gas Electric systems using a single 24VAC transformer are wired a...

Страница 6: ...ature Sensor Input Outdoor Temperature Sensor Input From Outdoor Temperature Sensor TS3 Terminal Function Discharge Air Temperature Sensor Model TS2 The optional discharge or leaving air temperature s...

Страница 7: ...nd releasing the MENU key accesses the User menu where settings and data can be viewed but not changed 9 EXT PDMi MENU MENU NEXT NEXT SAVE SAVE PDM Programming Display Module PDM Programming Display M...

Страница 8: ...and cooling the fan operation the supply air temperature limits outdoor changeover temperature for dual fuel heat pumps and number of zones being used Press No to continue Press Yes to change the siz...

Страница 9: ...ing control The equipment type is set by the jumper plugs and cannot be changed with PDMi3 Press Yes to continue to select additional options Press Yes to select conventional heat pump If equipment ty...

Страница 10: ...ats that can be used in that zone Press Up or Down to change the number of auxiliary heating stages Press NEXT to continue Press Up or Down to change the heating temperature limit Press NEXT to contin...

Страница 11: ...he bypass position of the damper when it is being used for bypass Press Next to set the bypass position of the next damper Press Up or Down to adjust the bypass position of the damper when it is being...

Страница 12: ...s NEXT to continue Press Yes to enter the minutes of fresh air operation required each hour Press No to select calculating the CFM and minutes per hour Press Yes to change the Fresh Air Option Press n...

Страница 13: ...pposite system service The panel normally services heating or cooling calls based on the number of calls from the zones If there are more heating calls than cooling it will service heating and vice ve...

Страница 14: ...t a test stage2 heating to insure discharge temperature is correct or return to the main menu if only one stage of heating is used Press Yes to start a bypass test A test will be started based on the...

Страница 15: ...Press NEXT to go to the next letter in the name Press SAVE to save the clone name Monitor HVAC Performance Y N LAT 122 Prs 0 55 BP Pos 0 NEXT Press Yes to display the leaving air temperature duct pres...

Страница 16: ...una Hills CA 92653 949 916 0945 Fax 949 458 8502 www ProZone US com Limited 5 Year Warranty The 5 year warranty is limited to the repair or replacement of defective product due to parts failure or def...

Отзывы: