background image

8

Display
e.g.

Meaning

Value
range

Typical 
setting

Current 
setting

dT min
3K

Temperature dif-
ference controller: 
Hysteresis dTmax

2 – 35K

3K

min
0:00
1(2,3)

Time frame1(2,3): 
Start 

0:00 – 23:59

0:00

max
23:59
1(2,3)

Time frame 1(2,3): 
Stop

0:00 – 23:59

23:59

min
6:00
  4

Time frame1(2,3): 
Start 
for tube collector 
function

0:00 – 23:59

6:00

max
20:00
  4

Time frame 1(2,3): 
Stop
for tube collector 
function

0:00 – 23:59

20:00

5.3 "Manual operation" menu 

Automatic operation is switched off  during manual operation. The outputs can be 
manually switched on and off  for servicing and testing purposes.

Once the menu has been exited or after 8 hours, automatic operation is reactivated.

Display

 

Meaning

Value range

Manually switching on / off  the switching 
output A1 (pump 1)

0 = Off 

1 = On

Manually switching on / off  the switching 
output A2 (pump 2 / valve 1)

0 = Off 

1 = On

3

Manually switching on / off  the switching 
output A3 (cooling, thermostat or temper-
ature diff erence controller function)

0 = Off 

1 = On

5.4 "Basic Setup" menu 

The hydraulic diagrams and additional functions are displayed in the Basic Setup 
menu. Settings must only be changed by a specialised technician. Settings may 
only be adjusted in the menu: 

a) within one minute after the device has been switched on

or

b) after simultaneously pressing the buttons: 

Display

Meaning

Value range

Factory 
setting

Current 
setting

Line Value

0

0

Collector protection 
function

0 = Off 
1 = On

0 = Off 

1

120°C

Collector protection 
function

110 – 150°C

120°C

2

0

Recooling function 
(only if the collector 
protection is on)

0 = Off 
1 = On

0 = Off 

3

40°C

Recooling storage tank 
temperature

30 – 90°C

40°C

 

Settings and changes in 
this menu must only be 

carried out by a specialised 
technician. Incorrect settings can 
damage or adversely aff ect the 
function of the solar power system.

 

Settings and changes in 
this menu must only be 

carried out by a specialised 
technician. Incorrect settings can 
damage or adversely aff ect the 
function of the solar power system.

 

Settings and changes in 
this menu must only be 

carried out by a specialised 
technician. Incorrect settings can 
damage or adversely aff ect the 
function of the solar power system.

 

Settings and changes in 
this menu must only be 

carried out by a specialised 
technician. Incorrect settings can 
damage or adversely aff ect the 
function of the solar power system.

Содержание SOLAREG II VISION plus

Страница 1: ...Microcontroller controlled temperature difference controller for solar thermal systems Operatingmanual Operatingmanual Solareg II VISION plus...

Страница 2: ...conditions 24 13 Declaration of conformity 24 The number of displayed values depends on the activated additional functions The number of displayed values depends on the activated additional functions...

Страница 3: ...Real time clock function Available accessories Temperature sensor PT1000 Yield measurement set incl tube sensor Sensor connection box Immersion sleeves 2 Safety instructions Always completely disconne...

Страница 4: ...Quick Info card provided with the device into the pocket provided on the back of the device The Quick Info card provides the user with an overview of the functions to facilitate rapid device operatio...

Страница 5: ...cope 2 to 6 sensors are required Mounting wiring the temperature sensors Mount the sensors on the collector and the storage tank Ensure proper heat transfer and use heat conducting paste if necessary...

Страница 6: ...Confirm a value change and store it 5 Menu structure 5 1 Info menu The following measured and yield values are displayed in the Info menu Display e g Meaning Can be reset 75 C Displays current collec...

Страница 7: ...permis sible temperature 15 95 C 65 C dT max 7K Storage tank 1 2 Switch on differ ence 3 40K 7K dT min 3K Storage tank 1 2 Switch off differ ence 2 35K 3K min 100 12 Set the minimum pump capacity usi...

Страница 8: ...n the Basic Setup menu Settings must only be changed by a specialised technician Settings may only be adjusted in the menu a within one minute after the device has been switched on or b after simultan...

Страница 9: ...tank systems Controller response time in s 30 480 240 10 1 First priority storage tank selection 1 2 1 11 0 Anti freeze function 0 Off 1 On 0 12 6 Anti freeze function Reference sensor selec tion 1 6...

Страница 10: ...onductor mains and outputs A1 Solar circuit pump switching output 1 A2 No function A3 Independent controller switching output 3 Sensor connections S1 Collector sensor S2 Lower storage tank S3 No funct...

Страница 11: ...eter Type 1 one collector two storage tanks with a three way valve A2 Off The valve must es tablish the connection between the collector and storage tank 1 Type 1 one collector two storage tanks with...

Страница 12: ...itching output 1 A2 Pump switching output 2 A3 Independent controller switching output 3 Sensor connections S1 Collector sensor S2 Lower storage tank 1 S3 Lower storage tank 2 S4 Collector return S5 O...

Страница 13: ...ler other temperature display S7 Option flow meter Type 3 two collectors one storage tank with a three way valve The valve must es tablish the connection between collector 1 and the storage tank Type...

Страница 14: ...outputs A1 Solar circuit pump 1 switching output 1 A2 Solar circuit pump 2 switching output 2 A3 Independent controller switching output 3 Sensor connections S1 Collector array 1 S2 Lower storage tan...

Страница 15: ...n the charging duration as well as an interruption of this func tion along with a waiting period to monitor the collector temperature Basic Setup menu Display Meaning Value range Factory set ting Line...

Страница 16: ...9 23 59 Heating If the measured temperature is below the target value output A3 is switched on until the measured temperature reaches the target value hysteresis Basic Setup menu Display Meaning Value...

Страница 17: ...erature differ ence controller function can also be selected 0 Off 1 Cooling 2 Heat ing 3 Tem perature difference controller 0 15 5 Sensor selection for the independ ent controller source 1 6 5 Progra...

Страница 18: ...only effective if the storage tank temperature is below the temperature limit 95 Therefore during the holiday period for example the storage tank is discharged at night to the set recooling temperatur...

Страница 19: ...y yield measurement The energy yield of the solar power system is calculated and displayed using the temperature difference between the collector and the collector return tempera ture and the measured...

Страница 20: ...d short circuits Errors are indicated by the symbol You can find the error source by scrolling up or down the Info menu 8 2 Flow monitoring The controller is programmed to display a message if the flo...

Страница 21: ...ensor if necessary Flashing Short circuit in the sensor cable Check cable Defective sensor Check sensor resistance and replace sensor if necessary Circulation error No flowSFlb Flashing Additional dis...

Страница 22: ...r Outputs are not switched on Controller is in manual operation Exit Manual operation Switch on condition is not satisfied Wait until switch on condition is satisfied Pump symbol rotates but the pump...

Страница 23: ...ing output Total power of all outputs 230V 1A approx 230VA for cos 0 7 1 0 2A approx 460VA maximum Fuse protection Fine wire fuse 5 x 20mm 2A T 2 amperes delayed action fuse Miscellaneous Recommended...

Страница 24: ...d within 1 month after PROZEDA GmbH has re ceived it If the device is not repaired within the two repairs attempts the buyer is entitled to delivery of a fully functional replacement product If a repl...

Отзывы: