O M M I S S I O N I N G
Commission your control unit in the following sequence:
?
Are the collector and storage cylinder sensors
correctly mounted
?
Has the correct sensor type been selected
(PT1000)?
Yes
No
Select and install the correct sensor
?
Is the power cable for the pump connected
correctly to the pump and the control unit?
Yes
No
Connect the cables correctly
If the pump is powered directly via a mains
cable: does the pump work?
Yes
Unplug the mains cable
No
Unplug the mains plug
Test the pump cable,
test the pump
Reconnect the pump to the control unit
?
Are the sensor cables for the collector and
storage cylinder sensors correctly connected to
the relevant control unit terminals?
Yes
No
Connect sensors correctly
With the mains supply switched off, connect the
control unit and then switch on the mains supply
(e.g. via a safety fuse):
?
Does the green “Mains” light lights up
Yes
No
Test the fuse on the device
Check the fuse protection on the
mains
?
Does the “Fault” light flash
No
Yes
Rectify fault as described in section 9
If the “Pump” light lights up, check whether the
pump is working.
Yes
No
Rectify fault as described in section 9
Control unit is ready for use. If necessary:
carry out settings for TSPmax*
Write down your settings:
Date
TSPmax
°C
°C
* TSPmax: maximum
temperature storage cylinder
* TSPmax: